Double Beam Spectrophotometer (UV Visible)

A UV-Vis spectrophotometer is used to determine the absorption of light from a sample and can be used as a detector for HPLC. A sample is placed in the UV/VIS beam and absorbance versus wavelength is measured. A double beam spectrophotometer utilizes two beams of light: a reference beam and a sampling beam that passes through the sample. Some double beam spectrophotometers have two detectors that allow the two beams to be measured at one time.

Find, compare, and request a quote for double beam spectrophotometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyJASCOJASCOJASCOJASCOJASCO
ItemV-750 UV-Visible SpectrophotometerV-730 UV-Visible SpectrophotometerV-760 UV-Visible SpectrophotometerV-770 UV-Vis/NIR SpectrophotometerV-780 UV-Vis/NIR Spectrophotometer
Citations
Figures
(1)
(1)
Catalog NumberV-750V-730V-760V-770V-780
Price
TypeUV-VisibleUV-VisibleUV-VisibleUV-Visible/NIRUV-Visible/NIR
Wavelength Range190 to 900 nm190 to 1,100 nm187 to 900 nm190 to 2,700 nm (3,200 nm, option)190 to 1,600 nm
Wavelength Accuracy±0.2 nm (at 656.1 nm)±0.2 nm (at 656.1 nm)±0.1 nm (at 656.1 nm)±0.3 nm (at 656.1 nm)
± 1.5 nm (at 1312.2 nm)
±0.3 nm (at 656.1 nm)
± 1.0 nm (at 1312.2 nm)
Scanning Speed10 to 4,000 nm/min (8,000 nm/min in preview mode)10 to 8,000 nm/min10 to 4,000 nm/min (8,000 nm/min in preview mode)10 to 4,000 nm/min (8,000 nm/min in preview mode)10 to 4,000 nm/min (80,00 nm/min in preview mode)
Spectral Bandwidth0.1, 0.2, 0.5, 1, 2, 5, 10 nm
L2, L5, L10 nm (low stray light mode)
M1, M2 nm (micro cell mode)
1.0 nm fixed0.1, 0.2, 0.5, 1, 2, 5, 10 nm
L2, L5, L10 nm (low stray light mode)
M1, M2 nm (micro cell mode)
UV-Vis:
0.1, 0.2, 0.5, 1, 2, 5, 10 nm
L2, L5, L10 nm (low stray light mode)
M1, M2 nm (micro cell mode)
NIR:
0.4, 0.8, 1, 2, 4, 8, 20, 40
L8, L20, L40 nm (low stray light mode)
M4, M8 nm (micro cell mode)
UV-Vis:
0.1, 0.2, 0.5, 1, 2, 5, 10 nm
L2, L5, L10 nm (low stray light mode)
M1, M2 nm (micro cell mode)
NIR:
0.2, 0.4, 0.5, 1, 2, 4, 10, 20
L4, L10, L20 nm (low stray light mode)
M2, M4 nm (micro cell mode)
Light SourceHalogen lamp, Deuterium lampHalogen lamp, Deuterium lampHalogen lamp, Deuterium lampHalogen lamp, Deuterium lampHalogen lamp, Deuterium lamp
Resolution=BS9=BS8=BS10=BS11=BS12
DescriptionThe V-750 UV-Visible Spectrophotometer optical design uses precision double-beam optics with variable spectral bandwidth. A high sensitivity PMT detector provides accurate and reproducible measurements for low to high concentration samples. By controlling the high voltage applied to the PMT, the ... Read MoreThe V-730 UV-Visible Spectrophotometer is designed for accurate and reliable absorption and transmittance measurements. Innovative features include IQ Accessory automatic recognition and IQ Start for push-button operation of routine measurements. The wide wavelength range from 190 to 1,100 nm ... Read MoreThe V-760 UV-Visible Spectrophotometer includes a double monochromator for exceptional resolution with extremely low stray light (0.00008 %) for more accurate measurement over the widest photometric range (up to 8AU). The V-760 provides excellent sensitivity for diffuse reflectance or transmittance ... Read MoreThe V-770 UV-Visible/NIR Spectrophotometer features a unique single monochromator design for maximum light throughput with excellent absorbance linearity. A PMT detector is used for the UV to visible region and a Peltier-cooled PbS detector for the NIR region.The V-780 UV-Visible/NIR Spectrophotometer features a single monochromator with automatically exchanged gratings: 1,200 lines/mm for the UV-Visible region and 600 lines/mm for the NIR region. A PMT detector is used for the UV-Visible region and a high sensitivity InGaAs detector in the NIR region. ... Read More
Get Quote