Application Notes Available for Bruker EVOQ with a Focus on Food Testing, Sports Medicine and Toxicology

November 28, 2012: Bruker Chemical and Applied Markets (CAM), Fremont, California, US: Following Bruker¹s recent introduction of the EVOQ liquid chromatography mass spectrometer (LC-MS/MS) four Application Notes have been released. The Application Notes examine the advantages of performing routine analyses on the Bruker EVOQ in areas such as the quantitation of chloramphenicol in milk, dermorphin detection in equine urine, clenbuterol in equine plasma and how to save time during bioanalyses. The Application Notes are available at bit.ly/BCA358 for free download.

Clenbuterol in Equine Plasma ­ A Study of Superior Ion Source Robustness and High Sensitivity Without the Use of a Divert Valve This application note demonstrates sustained high-sensitivity performance of the EVOQ Elite LC-TQ under repeated exposure to horse plasma samples. Clenbuterol in crashed horse plasma was injected (dilute-and-shoot) without the use of a divert valve. Four calibration curves were analyzed, distributed at the beginning, two bracketing the middle, and one at the end of the series. The success criterion was to achieve <10% relative standard deviation (%RSD) for the response factor for the four calibration curves dispersed within 500 horse plasma samples. A response factor %RSD of <5% (4.38%) was achieved using the EVOQ Elite  LC-TQ.

Quantitative Analysis of Chloramphenicol in Milk Using the EVOQ Qube

The EVOQ Qube LC-MS/MS method operated in multiple reaction monitoring (MRM) mode has been developed for detecting and confirming trace levels of chloramphenicol in milk matrix with minimal sample preparation. Three MRM transitions were used, one for quantification and two for qualification. The limit of quantification (LOQ) for chloramphenicol was 0.02 ppb with consistent ratios for the qualification ions. The calibration curve from 0.02 ppb to 1.0 ppb spiked in milk matrix is linear with R2 = 0.9980.

The Analysis of Dermorphin, an Opioid Peptide in Equine Plasma using the EVOQ Elite

Dermorphin, a naturally occurring hepta-peptide, is a potent analgesic approximately 40x more potent than morphine and a Class I prohibited substance in horse racing. Dermorphin was quantified in equine plasma using solid phase extraction cleanup. The linear dynamic range of the assay was 0.5-1000ng/mL and was easily achieved on the EVOQ Elite LC-TQ.

Meredith Conoley, Bruker CAM Marketing Director explained that "The EVOQ LC-MS/MS was designed to provide game changing performance for laboratories involved in high throughput quantitation. Innovation in both hardware and software has yielded revolutionary technology, like Active Exhaust, IQ dual ion funnel, the VIP-HESI, and the new PACER software, meaning that EVOQ can offer advantages to any laboratory conducting routine analysis in water and environmental testing, food, forensics, toxicology, sport medicine and discovery PK." Conoley went on to comment that, "these application notes demonstrate the EVOQ's outstanding capability to work under really tough conditions in demanding laboratories with sustained high-sensitivity".

For further information please visit EVOQms.com

About Bruker Corporation

For over 50 years Bruker Daltonics has embodied innovation with integrity as demonstrated by its development of world-class scientific instruments. Bruker¹s Chemical and Applied Markets (CAM) division, headquartered in Fremont, California was established in April 2010. Its formation was in response to the dynamic and ever significant separation and analysis market, providing fundamentally new instruments and solutions for customers in a range of applied industrial areas including: food testing, environmental analysis, toxicology testing, forensic analysis, quality control and pharmacokinetics. Today, Bruker's CAM division serves all of these industry areas, pioneering the migration of technology from research to the commercial laboratory.

For more information please visit www.bruker.com

Contacts:

Meredith Conoley
Bruker CAM Marketing Director
T: +1 (510) 683 4305
E: [email protected]

Jessica Auton
Account Director, Kapler Communications
Cell: +44 (0)7867 308122
E: [email protected]

More News

  • Researchers Propose New Regulations for Food Packaging Chemicals

    Scientists have proposed a new way to prioritize regulatory review of the more than 15,000 chemicals used in food packaging and other food contact materials, most of which currently lack the safety data needed to protect consumers. read more
  • Brain Activity Mirrors the Shape of Each Breath

    Each individual breath—not just breathing rate—is closely linked to the pattern of electrical activity in brain regions tied to cognition, emotion and memory, according to a new study that could help explain how breathing disorders turn deadly. read more
  • Body's Organs Age in Distinct, Synchronized Waves

    The human body doesn't age at a single, steady pace. Instead, each organ follows its own timeline, and organs that age quickly tend to have "aging partners" that speed up in sync, according to a new study that mapped structural aging across 40 types of tissue. read more