New OPTIC-4 injector - Most powerful multimode inlet for GC and GCMS

Applicable as Large Volume injector, Pyrolysis or Thermal Desorption injection system/
Fully automated analysis with AOC-5000 Plus/
Improved detection limits using cold injection system

Shimadzu, one of the worldwide leading manufacturers in analytical instrumentation, introduces the new OPTIC-4 injector, the 4th generation of the highly successful OPTIC multimode injection system from Atas GL, Eindoven, Netherlands. This versatile tool increases application range and detection limits of the Shimadzu GC and GCMS series.

Figure 1: New OPTIC-4 injector increases application range and detection limits of Shimadzu GC and GCMS systems.

Additional operation modes

In addition to the standard sampling modes, the programmable OPTIC-4 can be operated as Large Volume injector, Pyrolysis or Thermal Desorption injection system. DMI (Difficult Matrix Introduction) is also possible by injecting µ-vials filled with sample (solid or highly matrix-loaded) into the OPTIC-4 liner, allowing direct analysis of the compounds in the sample.

Highest temperature ramps by direct resistive heating

Figure 2: GCMS-QP2010 Ultra combined with OPTIC-4 injector.

The patented low thermal mass design together with direct resistive heating provides a linear temperature range up to 600 °C at rates as high as 60 °C/sec, opening the possibility to apply the OPTIC-4 for a wide range of applications. Combined with the AOC-5000 Plus auto sampler, fully automated sample injection can be utilized using an automatic liner exchanger (LINEX). The variety of different liners supports the wide range of applications using the OPTIC-4.

Improved detection limits

Using the OPTIC-4 injector as a cold injection system, compounds which usually degrade in hot injectors, e.g. thermal labile pesticides, can be analyzed without any difficulty. Precise and reproducible results can therefore be obtained for low boiling point compounds. The OPTIC-4 temperature range is +10 °C above RT to 600 °C (alternatively -180 °C or -50 °C to 600 °C with the injector cooling option using direct LN2 or CO2 cooling, respectively).
The unique solvent monitor enables easy method development for Large Volume injections, which improves detection limits and can be used in all application areas with a need for high sensitivity.

contact:

Uta Steeger,
Shimadzu Europa GmbH,
Albert-Hahn-Str. 6-10,
47269 Duisburg
Tel.: +49 (0) 203-7687-410,
e-mail: [email protected].

Additional information is available on Shimadzu’s website: www.shimadzu.eu

Download is possible via http://shimadzu.eu/press

More News

  • Researchers Propose New Regulations for Food Packaging Chemicals

    Scientists have proposed a new way to prioritize regulatory review of the more than 15,000 chemicals used in food packaging and other food contact materials, most of which currently lack the safety data needed to protect consumers. read more
  • Brain Activity Mirrors the Shape of Each Breath

    Each individual breath—not just breathing rate—is closely linked to the pattern of electrical activity in brain regions tied to cognition, emotion and memory, according to a new study that could help explain how breathing disorders turn deadly. read more
  • Body's Organs Age in Distinct, Synchronized Waves

    The human body doesn't age at a single, steady pace. Instead, each organ follows its own timeline, and organs that age quickly tend to have "aging partners" that speed up in sync, according to a new study that mapped structural aging across 40 types of tissue. read more