A Karl Fischer titrator, also known as a KF titrator, is used to determine the amount of water in a sample. Because the presence of water can affect many characteristics of a product, including reactivity, stability, and quality, KF titration is important to and is used in many industries. Food, oil, pharmaceutical, and semiconductor industries all use Karl Fischer titrators to maintain the quality of their products. There are two methods that can be used in Karl Fischer titration: volumetry, in which the amount of reagent that has been used determines the amount of water, and coulometry, in which an electrolysis reaction occurs and the amount of electricity used tells us the amount of water in the sample. Volumetry is appropriate to detect water amounts from 1 to 100 milligrams, while coulometry is the better choice for very small amounts of water, from 10 micrograms to 10 milligrams. When choosing the right Karl Fischer titrator, several factors should be considered, including sample size needed, if volumetric or coulometric titration is needed, time the titration will take, and how much of the process is automated and how much needs to be done by hand.
Find, compare, and request a quote for Karl Fischer titrators across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |  |  |
| Company | Metrohm USA | Metrohm USA | Metrohm USA | Metrohm USA | Metrohm USA |
| Item | Metrohm OMNIS KF Titrator | Metrohm Eco KF Titrator | Metrohm Karl Fischer Gas Analyzer | Metrohm KF Ti-Touch Mid-Range Titrator | Metrohm OMNIS Coulometer and Robot Oven |
| Reviews | | | | | |
| Catalog Number | 2.1001.4220 | 2.1027.0010 | 2.875.9020 / 2.875.9050 | 916 KF Ti-Touch | 210301020 |
| Price | | | | | |
| Description | OMNIS KF is a fully integrated solution for water content determination with volumetric Karl Fischer titration. Determining water in samples has never been more convenient, safer, and easier.
- Safe: All chemicals handled in a closed system, no contact with reagents.
- Easy: The water content
OMNIS KF is a fully integrated solution for water content determination with volumetric Karl Fischer titration. Determining water in samples has never been more convenient, safer, and easier.
- Safe: All chemicals handled in a closed system, no contact with reagents.
- Easy: The water content determination starts automatically with the sample injection.
- Convenient: the Karl Fischer reagent is supplied and removed automatically.
- Fast: easy and quick sample preparation with the OMNIS Karl Fischer instrument.
... Read More | The Eco KF Titrator with integrated magnetic stirrer und touch-sensitive display is ideal for routine water content determination. Predefined methods enable a smooth and easy instrument start-up. In addition to GLP-compliant printouts on paper or as PDFs, the Eco KF Titrator also offers the option The Eco KF Titrator with integrated magnetic stirrer und touch-sensitive display is ideal for routine water content determination. Predefined methods enable a smooth and easy instrument start-up. In addition to GLP-compliant printouts on paper or as PDFs, the Eco KF Titrator also offers the option of connecting balances or of sending the determination data to a PC via PC / LIMS reports.
Key features
- Simple and intuitive operation
- Accurate and precise results
- Safe handling of reagents
- GLP-compliant reporting and documentation
- Global on-site service and support
... Read More | Key features of Metrohm’s easy-to-use KF Gas Analyzer are its robust construction and the strict separation of gas-carrying system and electronic area. The 875 is equipped with an integral evaporator for liquefied gases, an inlet filter to separate out particles and an oil filter. A mass flow Key features of Metrohm’s easy-to-use KF Gas Analyzer are its robust construction and the strict separation of gas-carrying system and electronic area. The 875 is equipped with an integral evaporator for liquefied gases, an inlet filter to separate out particles and an oil filter. A mass flow controller provides precise gas flow measurement while magnetic valves ensure a fully automated measuring procedure.... Read More | «Reduce to the max» - this is the 915 KF Ti-Touch's concept. Metrohm's new compact Karl Fischer titrator offers the maximum in the class of stand-alone systems for routine analysis.
Features- Buret, stirrer, dosing system, membrane pump & Touch Control in a single unit
- Contact-free reagent
«Reduce to the max» - this is the 915 KF Ti-Touch's concept. Metrohm's new compact Karl Fischer titrator offers the maximum in the class of stand-alone systems for routine analysis.
Features- Buret, stirrer, dosing system, membrane pump & Touch Control in a single unit
- Contact-free reagent exchange
- Connect to intranet or LIMS − without PC!
- Paperless PDF reports − without PC!
- USB port: memory stick, printer,barcode reader, etc.
- One-touch titration
... Read More | The OMNIS Coulometer with OMNIS Sample Robot Oven (OSRO) is a fully automated Karl Fischer solution for trace-level moisture determination in pharmaceutical applications. Combining precise coulometric titration with automated oven-based gas extraction, the system enables accurate, reproducible The OMNIS Coulometer with OMNIS Sample Robot Oven (OSRO) is a fully automated Karl Fischer solution for trace-level moisture determination in pharmaceutical applications. Combining precise coulometric titration with automated oven-based gas extraction, the system enables accurate, reproducible analysis of solids and other challenging samples while minimizing manual handling. Designed for high sample throughput and data integrity, it supports unattended operation and integrates seamlessly into regulated laboratory workflows... Read More |
| Type | Karl Fischer Titrator | Karl Fischer Titrator | Coulometric | Volumetric | Inquire |
| Measuring Range | −2400 mV to +2400 mV | Inquire | Inquire | 0.05 to 100% | Inquire |
| Get Quote | | | | | |