An HPLC detector is used to analyze the components of the eluted mixture that is collected after being run through an HPLC column. Differences in detector type are based on what is being detected. Detection can be done by measuring absorbance, changes in reflex indices, molecular weight, and fluorescence among others. When selecting a detector, it is important to consider the sample type being analyzed. Some sample types will not work or will have lower sensitivity on particular detectors. Also of consideration is the type of information that is being sought by the analysis and what method will be used when running the column, for example, some detectors will work with the gradient method while others will not.
Find, compare, and request a quote for HPLC detectors across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |
| Company | Waters | Wyatt Technology | Waters | Wyatt Technology | Waters | Wyatt Technology |
| Item | Optilab™ Refractive Index Detector for HPLC/GPC | miniDAWN™ Multi-Angle Light Scattering (MALS) Detector for SEC-MALS | omniDAWN™ Multi-angle Light Scattering (MALS) Instrument |
| Citations | | | |
| Catalog Number | Optilab | miniDAWN | omniDAWN |
| Price | | | |
| Type | Refractive Index Detector | MALS and optional DLS | Multi-Angle Light Scattering (MALS) photometer |
| Detector(s) | Differential Refractive Index (dRI) | High-gain, high-dynamic range photodiodes at 3 detection angles for MALS. Optional avalanche photodiode for simultaneous dynamic light scattering measurements. | Inquire |
| Applications | GPC/SEC analysis of macromolecules by SEC-MALS | With SEC/GPC: determination of distributions of absolute molar mass, size, conformation, conjugate ratio. With Calypso CG-MALS: characterization of biomolecular interactions. | With standard SEC/GPC or EclipseTM (FFF system): determination of distributions of molar mass, size, conformation, conjugation ratio, and particle concentration. With the Calypso composition-gradient system: label-free characterization of biomolecular interactions, including self- and hetero-association as well as non-specific interactions. |
| Description | The Optilab™ is a unique dRI detector for standard HPLC/GPC with 256 times the detection power and 50 times the dynamic range over alternative RI detectors for chromatography. This detector measures the solvent's absolute refractive index, a requirement for MALS calculations, at the same The Optilab™ is a unique dRI detector for standard HPLC/GPC with 256 times the detection power and 50 times the dynamic range over alternative RI detectors for chromatography. This detector measures the solvent's absolute refractive index, a requirement for MALS calculations, at the same wavelength as the MALS detector, for maximum accuracy. With an operating window from 4°C - 65°C it is appropriate for both protein and polymer samples. Key benefits include its extraordinary range: -0.0047 to +0.0047 RIU (comparable to 25 mg/mL protein in PBS); the high-concentration version extends the range by 7x. Its sensitivity is ± 7.5 x 10-10 RIU across the entire measurement range. It also includes a high-resolution, touch-screen front panel that displays data graphs and diagnostics.... Read More | Couple the miniDAWN™ to your favorite HPLC or FPLC to determine the absolute molar masses and sizes of macromolecules and nanoparticles in solution from hundreds to millions of Daltons—without the need for column calibration standards. This sensitive unit requires as little as 25 ng injected Couple the miniDAWN™ to your favorite HPLC or FPLC to determine the absolute molar masses and sizes of macromolecules and nanoparticles in solution from hundreds to millions of Daltons—without the need for column calibration standards. This sensitive unit requires as little as 25 ng injected sample, 100 kDa polystyrene in THF (varies for other samples and solvents). The miniDAWN is engineered with self-contained modules that are easily replaced making it field serviceable. The system-ready monitors soise levels in real-time and an all-green status indicator lets you know when your system is ready for data collection. The optional DLS module uses the WyattQELS™ module, which fits inside the miniDAWN to providing on-line dynamic light scattering for determining radii down to 0.5 nm. All light scattering cells are subject to contamination by particles and to combat this issue the instrument has a self-cleaning, embedded COMET™ ultrasonic module. For maximum reliability and uptime, program the miniDAWN to automatically clean the cell after every run. The units may also be combined with a Calypso™ composition-gradient system to characterize biomolecular interactions.... Read More | Delivering up to 4× faster runs with half the sample, the omniDAWN™ multi-angle static light scattering (MALS) photometer is purpose-built for UPLC™ and UHPLC systems for non-destructive absolute molar mass and size characterization of macromolecules and nanoparticles in solution. It provides Delivering up to 4× faster runs with half the sample, the omniDAWN™ multi-angle static light scattering (MALS) photometer is purpose-built for UPLC™ and UHPLC systems for non-destructive absolute molar mass and size characterization of macromolecules and nanoparticles in solution. It provides exceptional sensitivity across a broad range of molecular weights, sizes, and concentrations, supported by advanced analysis modules, practical implementation guides, and intelligent system health monitoring to ensure reliable performance and streamlined workflows.... Read More |
| Wavelength Range | Inquire | Inquire | Inquire |
| Get Quote | | | |