HPLC Detector

An HPLC detector is used to analyze the components of the eluted mixture that is collected after being run through an HPLC column. Differences in detector type are based on what is being detected. Detection can be done by measuring absorbance, changes in reflex indices, molecular weight, and fluorescence among others. When selecting a detector, it is important to consider the sample type being analyzed. Some sample types will not work or will have lower sensitivity on particular detectors. Also of consideration is the type of information that is being sought by the analysis and what method will be used when running the column, for example, some detectors will work with the gradient method while others will not.

Find, compare, and request a quote for HPLC detectors across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyWaters | Wyatt TechnologyWaters | Wyatt TechnologyWaters | Wyatt Technology
ItemmicroDAWN™ Multi-Angle Light Scattering Instrument for UHP-SEC-MALSminiDAWN™ Multi-Angle Light Scattering (MALS) Detector for SEC-MALSomniDAWN™ Multi-angle Light Scattering (MALS) Instrument
Citations
(1)
Catalog NumbermicroDAWNminiDAWNomniDAWN
Price
TypeMALS and optional DLSMALS and optional DLSMulti-Angle Light Scattering (MALS) photometer
Detector(s)High-gain, high dynamic range, static light scattering detectors at 3 anglesHigh-gain, high-dynamic range photodiodes at 3 detection angles for MALS. Optional avalanche photodiode for simultaneous dynamic light scattering measurements.Inquire
ApplicationsWith SEC/GPC: determination of distributions of absolute molar mass, size, conformation, conjugate ratio.With SEC/GPC: determination of distributions of absolute molar mass, size, conformation, conjugate ratio. With Calypso CG-MALS: characterization of biomolecular interactions.With standard SEC/GPC or EclipseTM (FFF system): determination of distributions of molar mass, size, conformation, conjugation ratio, and particle concentration. With the Calypso composition-gradient system: label-free characterization of biomolecular interactions, including self- and hetero-association as well as non-specific interactions.
DescriptionThe microDAWN™ MALS detector performs absolute characterization of macromolecules eluting from UHPLC (or UPLC), determining molar mass and size independently of retention time and molecular reference standards. This instrument offers superb sensitivity over a wide range of molar mass, size and... Read MoreCouple the miniDAWN™ to your favorite HPLC or FPLC to determine the absolute molar masses and sizes of macromolecules and nanoparticles in solution from hundreds to millions of Daltons—without the need for column calibration standards. This sensitive unit requires as little as 25 ng injected ... Read MoreDelivering up to 4× faster runs with half the sample, the omniDAWN™ multi-angle static light scattering (MALS) photometer is purpose-built for UPLC™ and UHPLC systems for non-destructive absolute molar mass and size characterization of macromolecules and nanoparticles in solution. It provides ... Read More
Wavelength RangeInquireInquireInquire