Gravimetric sorption is a popular analytical method utilized for the determination of the rate of interaction between a gas and an either solid or liquid material. The gravimetric sorption technique works with a sample’s weight being continuously measured on a microbalance as gas pressure is modulated under a constant temperature. Sorption update is established based on the measured changes of weight.
|  |  |  |  |  |
| Company | Hiden Isochema | Hiden Isochema | Hiden Isochema | Hiden Isochema | Hiden Isochema |
| Item | IGA-001 Gravimetric Gas Sorption Analyzer | IMI-FLOW Manometric Gas Sorption Analyzer | IMI-HTP Hydrogen Storage Analyzer | XEMIS-003 Gravimetric Sorption Analyzer | XEMIS-100 Gravimetric Sorption Analyzer |
| Citations | | | | | |
| Reviews | | | | | |
| Catalog Number | IGA-001 | IMI-FLOW | IMI-HT | XEMIS-003 | XEMIS-100 |
| Price | | | | | |
| Temperature Range | 77 K to 1000 °C | 77 K to 773 K | 77 K to 500 °C | 77 K to 500 °C | 77 K to 500 °C |
| Pressure Range | 10 bar (standard) 20 bar (optional) | 100 bar (standard) 200 bar (optional) | 100 bar (standard) 200 bar (optional) | 170 bar (standard) 200 bar (optional) | 170 bar (standard) 200 bar (optional) |
| Description | The IGA-001 is a dedicated single component gas sorption analyzer for the study of gas interactions with both solids and liquids. Incorporating an ultra-sensitive microbalance, the IGA-001 measures changes in sample mass as a function of temperature and pressure. The unique IGA method analyzes real The IGA-001 is a dedicated single component gas sorption analyzer for the study of gas interactions with both solids and liquids. Incorporating an ultra-sensitive microbalance, the IGA-001 measures changes in sample mass as a function of temperature and pressure. The unique IGA method analyzes real time gravimetric data to determine kinetic parameters and simultaneously predict sorption equilibrium.
Features:
- Versatile and suitable for use with a wide range of gases, materials and methods
- Active pressure regulation from submillibar to 20 bar
- Fully programmable for advanced method development
- Unrivalled long term stability and continuous weight measurement
- Sample temperatures from 77 K to 1000 °C
- Fully upgradeable for dynamic and vapor sorption capability
... Read More | The IMI-FLOW combines the manometric gas sorption capabilities of all IMI analyzers with flowing mode operation and integrated mass spectrometry. Manometric mode offers high accuracy isotherm determination to 200 bar, while the flowing mode provides complete control of pressure, composition and flowThe IMI-FLOW combines the manometric gas sorption capabilities of all IMI analyzers with flowing mode operation and integrated mass spectrometry. Manometric mode offers high accuracy isotherm determination to 200 bar, while the flowing mode provides complete control of pressure, composition and flow rate. Integrated mass spectrometry allows downstream gas analysis for TPD and advanced methods.
Features:
- Sub-micromole gas sorption resolution
- High pressure operation from 77 K to 773 K
- Automatic switching between manometric and flowing mode operation
- Versatile control from standard methods to complete user-defined experiments
- Full integration of mass spectrometers from Hiden’s quadrupole range
... Read More | The IMI-HTP is designed to characterize hydrogen storage materials using Sieverts method up to pressures of 200 bar. High accuracy is ensured by a minimized dead volume, all-metal construction, high thermal stability and accurate pressure measurement. Every IMI-HTP is specified to meet the The IMI-HTP is designed to characterize hydrogen storage materials using Sieverts method up to pressures of 200 bar. High accuracy is ensured by a minimized dead volume, all-metal construction, high thermal stability and accurate pressure measurement. Every IMI-HTP is specified to meet the challenging demands of high pressure H2 operation, with permanent overpressure protection to satisfy the most rigorous safety requirements.
Features:
- Sub-microgram hydrogen sorption resolution
- High pressure operation from ambient temperature to 773 K
- Liquid N2 coolant options for low temperature physisorption
- Fully upgradable modular design
- Versatile instrument control, with fully programmable software
- Also operates with a range of other gases (N2, CH4, CO2, O2,…)
... Read More | The XEMIS series are high accuracy gravimetric sorption analyzers operating to 200 bar. Changes in sample mass are measured as a function of applied temperature and pressure to determine isotherms, isobars and sorption kinetics. Designed for operation with a full range of gas and vapor species The XEMIS series are high accuracy gravimetric sorption analyzers operating to 200 bar. Changes in sample mass are measured as a function of applied temperature and pressure to determine isotherms, isobars and sorption kinetics. Designed for operation with a full range of gas and vapor species including corrosives and flammables, the XEMIS series features active pressure regulation from 10-2 mbar: a controllable pressure range covering 7 orders of magnitude.
Features:
- Isotherm, isobar and high pressure TGA measurements in a single automated analyzer
- Compatible with flammable, corrosive and toxic gases and vapors
- Symmetric geometry, with ultra-low total system buoyancy for high accuracy measurements at high pressures
- Measurements at temperatures from 77 K to 500 °C
- Fast and accurate analysis of equilibria and kinetics using the IGA method
- Full automation and advanced programmability
... Read More | The XEMIS series are high accuracy gravimetric sorption analyzers operating to 200 bar. Changes in sample mass are measured as a function of applied temperature and pressure to determine isotherms, isobars and sorption kinetics. Designed for operation with a full range of gas and vapor species The XEMIS series are high accuracy gravimetric sorption analyzers operating to 200 bar. Changes in sample mass are measured as a function of applied temperature and pressure to determine isotherms, isobars and sorption kinetics. Designed for operation with a full range of gas and vapor species including corrosives and flammables, the XEMIS series features active pressure regulation from 10-2 mbar: a controllable pressure range covering 7 orders of magnitude.
Features:
- Isotherm, isobar and high pressure TGA measurements in a single automated analyzer
- Compatible with flammable, corrosive and toxic gases and vapors
- Symmetric geometry, with ultra-low total system buoyancy for high accuracy measurements at high pressures
- Measurements at temperatures from 77 K to 500 °C
- Fast and accurate analysis of equilibria and kinetics using the IGA method
- Full automation and advanced programmability
... Read More |
| Applications | Energy storage, Gas solubility, Gas adsorption capacity determination, Thermodynamic and kinetic studies, Specific surface area (BET) determination | Gas storage, Gas separation and purification, Thermodynamic and kinetic studies, Nanoporous materials (carbons, zeolites, MOFs and polymers) | Hydrogen storage capacity determination, Pressure-Composition-Temperature (PCT) measurements, Thermodynamic and kinetic studies, Metal hydrides and nanoporous materials (carbons, zeolites, MOFs and polymers) | High pressure catalysis, Flue gas desulfurization, Gas-solid reaction kinetics | Energy gas storage, High pressure TGA, Polymer membrane characterization |
| Get Quote | | | | | |