Fingerprint development chambers are commonly used in the forensic sciences to accelerate the processing of latent finger-prints. Typically, these chambers use development chemicals such as Diazafluoren (DFO) or Ninhydrin for print processing, which are the most effective for detecting latent prints on paper and similar porous surfaces, however other chemicals can be used. Chambers can either be benchtop or floorstanding for higher throughput.
|  |  |  |  |
| Company | Mystaire | Mystaire | Mystaire | Mystaire |
| Item | Ninhydrin Fingerprinting Humidified Incubators | Advance Forensic Workstation | Advanced Cyanoacrylate Fuming Chambers | High Capacity Fuming Chambers |
| Catalog Number | MY-5000 / MY-8000 | FE-36 | CA-3000 / CA-6000 / CA-9000 | CA-9000 |
| Price | | | | |
| Description | Improve fingerprint development on paper and porous items with heat and humidity offered by the MY-8000 Incubator.
Humidified incubators offer warm temperatures with controlled additive humidity. Across the temperature range of 20-50°C, ±1°C at the sensor, these chambers can control relative Improve fingerprint development on paper and porous items with heat and humidity offered by the MY-8000 Incubator.
Humidified incubators offer warm temperatures with controlled additive humidity. Across the temperature range of 20-50°C, ±1°C at the sensor, these chambers can control relative humidity from setpoints of 50% through 80%.
Incubators have stainless steel interiors, exteriors and hinged glass doors, digital display of temperature/RH conditions and setpoints, temperature failsafes, four levels of epoxy coated wire shelves, fluorescent lamps, and casters.
... Read More | The new forensic workstation is the first system designed specifically for the development of latent fingerprints with both powders and Ninhydrin. Worker safety is our number one priority and this system is highly effective at reducing the potential for exposure to these common forensic chemicals.
The new forensic workstation is the first system designed specifically for the development of latent fingerprints with both powders and Ninhydrin. Worker safety is our number one priority and this system is highly effective at reducing the potential for exposure to these common forensic chemicals.
Internal fans draw a constant flow of air into the system. A combination of filters work together to contain powders and vapors before returning clean air to the lab. The workstation is built from steel and protected with a glossy, easy-to-clean finish. The sides and front panels are acrylic which allows you to clearly see your evidence. Misonix stands behind each unit with a 2-year warranty.
Features - 100 fpm face velocity
- Low airflow alarm
- Clear acrylic top, front and side panels
- Fiberglass spill tray (removable)
- Sparkless internal blower
- Steel chassis construction
- Electrostatic particle filter
- Carbon or HEPA filters; included
- (1) stainless steel hanging rod
... Read More | Mystaire CA Series Cyanoacrylate fuming chambers are the standard by which automated latent print development chambers are measured. The patented* recirculation filtration system with precise process controls for time, temperature and humidity put Mystaire CA chambers in a class of their own. TheMystaire CA Series Cyanoacrylate fuming chambers are the standard by which automated latent print development chambers are measured. The patented* recirculation filtration system with precise process controls for time, temperature and humidity put Mystaire CA chambers in a class of their own. The CA Series is constructed from powder coated aluminum with an automatically locking safety glass viewing door. Microprocessor control allows the operator to set fuming cycle time and relative humidity levels between 50-80%. Using the CA Series is simple; position the non-porous evidence inside the chamber, add cyanoacrylate to the heating element and push the start button to begin fuming.
Features
Microprocessor Controller - Fully automated, user programmable development system
- LCD display of fuming options and development and system parameters
- Accurate, user-programmable control of relative humidity from 50-80%
- User-definable fuming cycle length
- Internal circulation fan is user programmable - promotes even cyanoacrylate vapor distribution within chamber
- 110V and 220V AC configuations
Best In Class Safety - Patented, recirculatory filtration design (US Patent # 6,660,054)
- Specialized blended gas phase filtration media for cyanoacrylate
- Door automatically locks during development and purge cycles
- Constant filter life monitoring of pre-filtration and gas phase filtration
- Filtrak™ positive sealing system - eliminates bypass of potential harmful cyanoacrylate fumes
CA-3000 and CA-6000 Construction - Powder coated aluminum chamber
- Automatic locking safety glass viewing door
- Vapor-proof fluorescent lightning
CA-9000 Construction - Powder coated aluminum and steel chamber for strength and integrity
- Automatic locking safety glass viewing door
- Vapor-proof fluorescent lighting
- Removable epoxy resin floor is structurally reinforced for heavier evidentiary items
... Read More | Our Fuming Chambers are fully automated fingerprinting systems.
The CA-9000 is a high volume, stand alone fingerprinting chamber. Designed to a government agency's standards, this model is for departments that must process large amounts of evidence on a regular basis. Large items such as doors, tiresOur Fuming Chambers are fully automated fingerprinting systems.
The CA-9000 is a high volume, stand alone fingerprinting chamber. Designed to a government agency's standards, this model is for departments that must process large amounts of evidence on a regular basis. Large items such as doors, tires, bicycles and tents are regularly processed in this unit.
This models offers the same functionality as our smaller, table-top versions except for one feature - the CA-9000 can be either ductless or ducted to the outside. We are able to customize the dimensions of this model to meet the needs of your particular laboratory.
Features
- Programmable Controls - Obtain quality latent prints and reproducible results by controlling humidity, fume circulation and processing times.
- Full automation of fuming process
- Fuming and filtering intervals customized to user preference
- Monitors number of fume cycles to track filter life
- Safety Features - Workers are protected from hazardous fumes by a solenoid lock that prevents access to the chamber until the fumes are evacuated.
- Prevents exposure to CA fumes
- Completely sealed unit
- Multi-layered carbon filter
- Ductless Design - Bench-top size, no ductwork and no installation costs.
- Easy to clean safety glass
- Constructed of aluminum and steel
- Portable
... Read More |
| Temperature Range | 20°C to 50°C | Inquire | Up to 160°C | Up to 160°C |
| Exterior Dimensions | (WxDxH) 33 x 31 x 78.5 in (casters add an additional 3 in) | (WxDxH) 36 x 28 x 28 in | Varies by model | (WxDxH) 72 x 48 x 94 in |
| Interior Dimensions | (WxDxH) 29 x 27 x 55 in | (WxDxH) 35 x 19.5 x 27.25 in | Varies by model | (WxDxH) 70 x 46 x 76 in |
| Humidity Range | 50 to 80% | Inquire | up to 80% | up to 80% |
| Get Quote | | | | |