Ultra pure water is water nearly or completely devoid of contaminants. Ultrapure water systems are an important component for laboratories across markets including manufacturing and the semi-conductor industry. These ultra pure water systems remove chemical contaminants through de-ionization (DI) and reverse osmosis. An ultra pure water system eliminates bacteria with UV radiation. These laboratory water purification systems can achieve up to 18.2 MOhm-cm in resistivity (high resistivity indicating low levels of anionic contamination) and can reduce organic carbon to less than 50 ppb. An ultrapure water system is equipped with ultra filters to remove endotoxins, DNase and Rnase left over from bacteria destroyed by UV, resulting in extremely low total organic carbon (TOC). Additional carbon filters in these laboratory water purification systems reduces the need for pre-treatment, permitting tap water as a source.
Find, compare, and request a quote for ultrapure water systems across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |
| Company | Stakpure GmbH | Stakpure GmbH | Stakpure GmbH |
| Item | OmniaTap xstouch | OmniaLabDS | OmniaLabED+ |
| Price | | | |
| Description | The OmniaTap xstouch (Blueline series) is an intelligent compact water purification system with intuitive touchscreen operation that simultaneously produces Type I ultrapure water and Type II pure water from a single unit connected directly to tap water. It combines RO, ion exchange, UV, TOC The OmniaTap xstouch (Blueline series) is an intelligent compact water purification system with intuitive touchscreen operation that simultaneously produces Type I ultrapure water and Type II pure water from a single unit connected directly to tap water. It combines RO, ion exchange, UV, TOC monitoring, and optional ultrafiltration. Available in two models: OmniaTap xstouch 8 UV-TOC and OmniaTap xstouch 8 UV-TOC/UF.... Read More | The OmniaLabDS is a CLRW/CLSI-grade pure water system designed for feeding clinical analyzers, steam sterilizers, and washer-disinfectors. Available in 20, 40, and 60 l/h output models, it features a 100 L pressurized tank with quality recirculation, regenerative polishing cartridges, a 0.2 µm The OmniaLabDS is a CLRW/CLSI-grade pure water system designed for feeding clinical analyzers, steam sterilizers, and washer-disinfectors. Available in 20, 40, and 60 l/h output models, it features a 100 L pressurized tank with quality recirculation, regenerative polishing cartridges, a 0.2 µm sterile filter, UV disinfection, and an optional emergency supply. Complies with DIN EN 285 and EN ISO 15883 international water standards.... Read More | The OmniaLabED+ is a large all-round ultrapure and pure water system designed for high-demand laboratories requiring both Type I ultrapure water and Type II pure water. Features continuously self-regenerating electro-deionization (EDI), a 100-liter recirculating storage tank with pressurized outlet,The OmniaLabED+ is a large all-round ultrapure and pure water system designed for high-demand laboratories requiring both Type I ultrapure water and Type II pure water. Features continuously self-regenerating electro-deionization (EDI), a 100-liter recirculating storage tank with pressurized outlet, and complies with ASTM, ISO 3696, and CLSI (CLRW) standards. Available in 20 L/h and 40 L/h variants with optional UV-TOC monitoring.... Read More |
| Method | Reverse osmosis (RO) + ion exchange + UV irradiation + TOC monitoring; UV-TOC/UF model additionally includes ultrafiltration (UF) for endotoxin, RNase, DNase, and protease removal | RO cartridge ? stainless steel regenerative polishing cartridge ? 0.2 µm sterile filter capsule ? UV disinfection; sterile overflow and sterile vent filter + CO2 absorber included; optional UV tank disinfection and emergency supply | Reverse Osmosis (RO) + Electro-Deionization (EDI) + UV |
| Output | 8 L/h (Type II pure water at 15°C); up to 2 L/min dispensing (Type I ultrapure water) | 20 l/h (OmniaLabDS20), 40 l/h (OmniaLabDS40), 60 l/h (OmniaLabDS60) at 15°C | 20 L/h or 40 L/h (Type II pure water); up to 2 L/min dispenser (Type I ultrapure water); 100 L/h at 2 bar pressurized tank outlet |
| Resistivity | 18.2 MO·cm at 25°C (Type I ultrapure water); 10–15 MO·cm at 25°C (Type II pure water) | 10 up to 1 MO·cm | 18.2 MO·cm (Type I); 10 MO·cm down to 1 MO·cm (Type II conductivity 0.1–1 µS/cm) |
| Dimensions | Without tank (with OptiFill touch dispenser): 240 x 530 x 435 mm (W x H x D); With 7 L docking tank: 253 x 530 x 520 mm; Production unit without tank (under-table): 240 x 415 x 310 mm; OptiFill touch wall dispenser: 90 x 482 x 337 mm; OptiFill touch bench dispenser: 250 x 650 (750 with extension) x 380 mm | Tower: 511 x 1520 x 575 mm (W x H x D); Base cabinet (tank): 511 x 800 x 575 mm (W x H x D) | Tower: 511 x 1520 x 575 mm (W x H x D); Base cabinet (tank): 511 x 800 x 575 mm (W x H x D) |
| Total Organic Carbon (TOC) | < 5 ppb (Type I ultrapure water, both models); real-time TOC monitoring included | < 2 ppm (feed water requirement) | < 10 ppb (standard models); < 5 ppb (UV-TOC monitoring models) |