| Description | The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting conditions.
Measuring ranges:
- 40 / 400 / 4000 / 40000 / 400000 lux
-
Measuring units: Lux or footcandles
-
Measuring accuracy: ± 3 %
-
Accuracy geared towards LED white light especially for LEDs
-
MIN- / MAX- / AVG-HOLD
-
2.5 measurements per second
-
Internal memory: 99 measured values
... Read More | This state-of-the-art video Condition Monitoring is the essential tool for all professional visual inspections and detailed inspections in hard-to-reach places. It combines an extremely slim design with advanced recording functions to guarantee you maximum precision.
The centerpiece of the inspectionThis state-of-the-art video Condition Monitoring is the essential tool for all professional visual inspections and detailed inspections in hard-to-reach places. It combines an extremely slim design with advanced recording functions to guarantee you maximum precision.
The centerpiece of the inspection system is the camera probe, which is only 6.2 mm / 0.24 in in size and has flexible 2-way articulation. This swiveling function enables precise control of the tip of the Condition Monitoring in two directions to inspect hidden angles and side walls with ease. To ensure an excellent view, six bright LEDs are integrated into the camera probe, the brightness of which can be individually adjusted to optimally adapt the illumination to the respective environment.
For documentation purposes, the Condition Monitoring provides sharp image and video recordings in a maximum resolution of 1920 x 1080 (Full HD). All recordings are conveniently stored on the 32 GB micro SD card supplied. Flexibility is increased by the robust, 1 meter long camera cable, which allows easy insertion into narrow cavities and pipes. For detailed analysis, the device offers a 4x digital zoom and an image rotation function to perfectly adjust the orientation of the image to the inspection situation. This powerful Condition Monitoring is supplied with a practical carrying case for safe and convenient storage.... Read More | Our Decibel Meter is specially designed to precisely detect and measure short, pulse-like noises such as explosions, blows or bangs. The Decibel Meter records sound levels within a range from 20 to 130 dB, with three manual measurement ranges available. Our Decibel Meter offers various measurement Our Decibel Meter is specially designed to precisely detect and measure short, pulse-like noises such as explosions, blows or bangs. The Decibel Meter records sound levels within a range from 20 to 130 dB, with three manual measurement ranges available. Our Decibel Meter offers various measurement functions such as Hold, Max and Leq in order to visualise the sound level in the best possible way.
For an accurate time weighting, the Decibel Meter supports the settings Fast, Slow and Pulse as well as the A, C and Z frequency weightings. This allows sound within the frequency range from 20 to 8000 Hz to be recorded in a filtered manner. Equipped with an integrated 1/2-inch condenser microphone and an RS-232 interface, the device offers a wide range of applications. Its short response time makes it possible to reliably register sudden sound pressure peaks.
The internal memory function allows the storage of up to 800 individual measurements as well as regular measurements over a period of up to 6 days, which can be saved automatically. The Decibel Meter fulfils several standards: IEC 61672-1, GB/T3785.2-2010 and JJG 188-2017, all in class II - making it the ideal choice for standard-compliant measurements. It can accurately capture the rapid fluctuations in sound levels and is therefore important for noise control measurements, peak sound level assessment and industrial and environmental compliance. ... Read More | Radiation Detector / measurement of gamma, beta and X-rays / adjustable alarm values / numerical and graphical display / min, max and average values
Our Radiation Detector is mainly used to measure gamma, beta and X-rays and uses a Geiger-Müller counter to measure the intensity of ionising Radiation Detector / measurement of gamma, beta and X-rays / adjustable alarm values / numerical and graphical display / min, max and average values
Our Radiation Detector is mainly used to measure gamma, beta and X-rays and uses a Geiger-Müller counter to measure the intensity of ionising radiation. The measuring range extends from 0 ... 10 mSv/h. The cumulative dose, average and maximum dose are shown on the larg 2.3 inch multifunctional display, while the real-time measurements are also shown graphically.
The device has two alarm modes: the radiation alarm (0 ... 100 µSv/h) and the cumulative radiation alarm (0 ... 100 mSv). Both alarms are equipped with different settings for visual, audible and vibrating warning signals. The energy range of the device is between 48 and 1500 keV. The radiation measuring device is equipped with a micro USB interface and a rechargeable lithium battery.
The Radiation Detector also displays the current battery level so that the user is always informed. The brightness of the display can be adjusted as required so that it is easier to read even in different lighting conditions. The date and time are also shown on the display.
This Radiation Detector is ideal for applications in research, medicine, industry and environmental protection. It can be used in nuclear power stations, hospitals, laboratories, radiation monitoring and emergency scenarios. Furthermore, it is also useful for construction companies that are working with radioactive materials and in environmental monitoring to ensure that radiation exposure remains within safe limits.... Read More | A Thermometer is an indispensable device for monitoring indoor air quality. It can be used in various areas, such as homes, offices, workshops, schools or public facilities. The Thermometer reliably measures the ozone content in the air and helps to recognize dangerous concentrations at an early A Thermometer is an indispensable device for monitoring indoor air quality. It can be used in various areas, such as homes, offices, workshops, schools or public facilities. The Thermometer reliably measures the ozone content in the air and helps to recognize dangerous concentrations at an early stage and react accordingly.
The device records ozone values in the range of 0.00 ... 50.0 ppm with a high resolution of 0.01 ppm. In addition, the detector measures the relative humidity between 20 ... 85% (resolution: 1%) as well as the temperature in the range of -10 ... 50°C / 14 ... 122°F, whereby the temperature display can also be switched to Fahrenheit. All measured values are shown on an easy-to-read 2-inch LCD display with backlighting.
For even more convenience, the Thermometer has a standby mode that can be activated manually. If no input is made within 60 seconds, the display switches off automatically - but the device remains active. In the event of increased ozone values, the detector warns with a visual and acoustic alarm. This is supported by a traffic light function: green for 0.00 ... 0.10 ppm, orange for 0.11 ... 0.20 ppm and red for 0.21 ... 50.0 ppm. As soon as the limit value of 0.10 ppm is exceeded, an additional acoustic warning signal sounds to indicate a possible hazard.
Equipped with an integrated rechargeable lithium battery that can be conveniently charged via USB-C, the detector is particularly flexible to use. An integrated rubber strap makes it easy to transport and allows the device to be conveniently carried or hung up. A Thermometer is suitable for private individuals as well as for professionals in schools, care facilities, offices or industrial environments - wherever a safe indoor climate is important.... Read More |