| Description | The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting conditions.
Measuring ranges:
- 40 / 400 / 4000 / 40000 / 400000 lux
-
Measuring units: Lux or footcandles
-
Measuring accuracy: ± 3 %
-
Accuracy geared towards LED white light especially for LEDs
-
MIN- / MAX- / AVG-HOLD
-
2.5 measurements per second
-
Internal memory: 99 measured values
... Read More | The Condition Monitoring is certified in accordance with IEC 61672-1:2013, Class 1 and is ideally suited for professional use in noise monitoring. With a wide frequency range from 10 Hz to 20 kHz and extensive filter options, the device enables precise measurements in almost all areas of applicationThe Condition Monitoring is certified in accordance with IEC 61672-1:2013, Class 1 and is ideally suited for professional use in noise monitoring. With a wide frequency range from 10 Hz to 20 kHz and extensive filter options, the device enables precise measurements in almost all areas of application. The frequency weightings A, C and Z as well as the time weightings S (Slow), F (Fast) and I (Impulse) are supported in order to always ensure application-appropriate measurement behaviour.
The Condition Monitoring also impresses with its comprehensive connectivity: Ethernet, WiFi and USB Type-C enable flexible and uncomplicated data transfer. The internal 8 GB memory and optional SD cards with up to 64 GB provide sufficient storage capacity for extensive measurement campaigns. The high-resolution 4-inch TFT touch display ensures intuitive and convenient operation. Measured variables such as Lp, Lmax, Lmin, Leq, Lpeak, LN(1-99) and numerous other useful functions are displayed clearly and in detail, enabling professional detailed evaluation of the measurement results with this Condition Monitoring.
Its wide range of applications makes the Condition Monitoring the ideal solution for environmental noise monitoring, traffic noise analysis, noise exposure assessment, occupational health and safety monitoring and airport noise monitoring.
The software included in the scope of delivery extends the functionality considerably: it enables live data reception via Ethernet or WiFi, access to stored measurement data and the export of results as a PDF report or CSV file. In addition, the display of the measurement parameters can be freely configured within the software, allowing customisation to specific analysis requirements.... Read More | Laboratory for liquids up to 5 litres / Stirring speed up to 1600 rpm / 1 stirring position / Stirring plate - acrylic glass / Compact
The Laboratory is a compact and powerful laboratory device for the efficient mixing of liquids. With an adjustable stirring speed of 200 to 1600 rpm, it is ideal Laboratory for liquids up to 5 litres / Stirring speed up to 1600 rpm / 1 stirring position / Stirring plate - acrylic glass / Compact
The Laboratory is a compact and powerful laboratory device for the efficient mixing of liquids. With an adjustable stirring speed of 200 to 1600 rpm, it is ideal for volumes of up to 5 liters. The robust stirring plate made of acrylic glass with dimensions of 173 × 180 mm provides a stable work surface.
The Laboratory is driven by a brushless motor, which guarantees particularly quiet and low-maintenance operation. The stirring rod supplied measures 8 mm in diameter and is 30 mm long - ideal for a wide range of everyday laboratory applications. With a power consumption of just 10 watts, the Laboratory is also extremely energy-efficient. Power is supplied flexibly via 100 to 240V AC at 50/60 Hz.
Typical areas of application are chemical and biological laboratories, research facilities and industrial processes where reliable and uniform mixing is required.... Read More | Illuminometer with external probe / Sampling rate 4 Hz / Measuring range 0 ... 400 kLux / Micro-USB interface / Units: lux, footcandle. The illuminometer has additional functions so that an analysis of the illuminance can be carried out. With the additional functions of the illuminometer the largestIlluminometer with external probe / Sampling rate 4 Hz / Measuring range 0 ... 400 kLux / Micro-USB interface / Units: lux, footcandle. The illuminometer has additional functions so that an analysis of the illuminance can be carried out. With the additional functions of the illuminometer the largest and smallest measured value can be output using the "MIN" and "MAX" buttons. In addition, the displayed measured value can be set in relation to a reference using the "REL" button. With the "PEAK" function, the illuminometer records peak values. The illuminometer has a sampling rate of 10 µs. The PCE-LMD 10 also has a data memory of 32,000 measured values. The measured values ??from the illuminometer can be read out and analyzed on the PC after a measurement. A live measurement on the PC with the illuminometer is also possible. The data from the illuminometer can be exported in CSV format for further processing.... Read More | This modern Oscilloscope impresses with a real-time sampling rate of up to 1 GSa/s and an analogue bandwidth of 100 MHz per channel. It is ideal for the precise acquisition of both periodic analogue and aperiodic digital signals. Thanks to the 7-inch colour TFT LCD touchscreen with a resolution of This modern Oscilloscope impresses with a real-time sampling rate of up to 1 GSa/s and an analogue bandwidth of 100 MHz per channel. It is ideal for the precise acquisition of both periodic analogue and aperiodic digital signals. Thanks to the 7-inch colour TFT LCD touchscreen with a resolution of 800 × 480 pixels, the Oscilloscope can be operated intuitively. The slim and lightweight design makes it particularly mobile and flexible to use.
The Oscilloscope offers complete trigger functions (single/normal/automatic) and a practical one-button auto-setup function to quickly adjust signals. An integrated high-voltage protection module ensures safe measurements by tolerating continuous voltages of up to 400 V. The powerful waveform image manager also enables functions such as thumbnail view, detailed view, page turning, zooming and panning. A Lissajous graphic display for amplitude, frequency and phase analysis and an FFT view for analysing harmonics are also available, while a high-performance lithium battery with 6,000 mAh capacity enables up to four hours of continuous operation. This makes the Oscilloscope ideal for mobile use. With an internal 1 GB memory, up to 1000 screenshots and as many sets of waveform data can be saved. The data can be transferred to a computer as a file via the USB-C interface.
The scope of delivery includes two 100 MHz probes and accessories as well as a power supply unit with data cable. This makes the Oscilloscope perfect for analysing and diagnosing signal interference in circuits, power supply units or control units as well as in the development of electronic components.... Read More |