| Description | Illuminometer with external probe / Sampling rate 4 Hz / Measuring range 0 ... 400 kLux / Micro-USB interface / Units: lux, footcandle. The illuminometer has additional functions so that an analysis of the illuminance can be carried out. With the additional functions of the illuminometer the largestIlluminometer with external probe / Sampling rate 4 Hz / Measuring range 0 ... 400 kLux / Micro-USB interface / Units: lux, footcandle. The illuminometer has additional functions so that an analysis of the illuminance can be carried out. With the additional functions of the illuminometer the largest and smallest measured value can be output using the "MIN" and "MAX" buttons. In addition, the displayed measured value can be set in relation to a reference using the "REL" button. With the "PEAK" function, the illuminometer records peak values. The illuminometer has a sampling rate of 10 µs. The PCE-LMD 10 also has a data memory of 32,000 measured values. The measured values ??from the illuminometer can be read out and analyzed on the PC after a measurement. A live measurement on the PC with the illuminometer is also possible. The data from the illuminometer can be exported in CSV format for further processing.... Read More | Our robust socket square inserts are specially designed for use with impact wrenches and are ideal for demanding bolting applications. The range covers thread sizes from M16 to M48 and offers the right wrench sizes for a wide variety of applications.
These high-quality socket square inserts impress Our robust socket square inserts are specially designed for use with impact wrenches and are ideal for demanding bolting applications. The range covers thread sizes from M16 to M48 and offers the right wrench sizes for a wide variety of applications.
These high-quality socket square inserts impress with their high load-bearing capacity, precise fit, and long service life – perfect for professional use in industry and assembly.... Read More | The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting The illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting conditions.
Measuring ranges:
- 40 / 400 / 4000 / 40000 / 400000 lux
-
Measuring units: Lux or footcandles
-
Measuring accuracy: ± 3 %
-
Accuracy geared towards LED white light especially for LEDs
-
MIN- / MAX- / AVG-HOLD
-
2.5 measurements per second
-
Internal memory: 99 measured values
... Read More | The Oxygen Meter is a reliable measuring instrument for monitoring the oxygen concentration in ambient air. With a measuring range of 0 to 30% vol. oxygen and a resolution of 0.1% vol., the Oxygen Meter delivers precise readings for a wide range of applications in industry, laboratories, storage, The Oxygen Meter is a reliable measuring instrument for monitoring the oxygen concentration in ambient air. With a measuring range of 0 to 30% vol. oxygen and a resolution of 0.1% vol., the Oxygen Meter delivers precise readings for a wide range of applications in industry, laboratories, storage, and occupational safety.
In addition to oxygen measurement, the device also records temperature and humidity. The integrated oxygen, temperature, and humidity sensor enables comprehensive monitoring of ambient conditions. Oxygen measurement is performed with an accuracy of ±0.3% of reading, while temperature values in the range of -9 to 55°C and humidity values from 0 to 100% RH are displayed.
For easy evaluation, the Oxygen Meter features a graphical trend display. This makes it possible to track changes in measured values directly on the device. In addition, up to 100,000 data sets can be stored, allowing even longer measurement series to be documented reliably.
An adjustable alarm warns the user when oxygen values become critical. This makes the Oxygen Meter ideal for continuous monitoring of areas where a safe oxygen concentration is important. The built-in 3000 mA lithium battery ensures flexible mobile use and operation independently of a fixed power supply.
This Oxygen Meter is ideal for applications in industry, laboratories, warehousing, occupational safety, and building services. Wherever oxygen concentration needs to be monitored reliably, the Oxygen Meter supports control of room air and helps to identify critical oxygen values at an early stage.... Read More | The Sound Sensor is ideal for all applications where ambient noise or noise levels need to be monitored precisely. Whether in urban noise measurement stations, on factory floors, in schools or in research projects - this Sound Sensor provides reliable measured values to fulfil safety and comfort The Sound Sensor is ideal for all applications where ambient noise or noise levels need to be monitored precisely. Whether in urban noise measurement stations, on factory floors, in schools or in research projects - this Sound Sensor provides reliable measured values to fulfil safety and comfort requirements. The sensor covers a measuring range of 30 ... 120 dBA and operates in the frequency range from 20 ... 12500 Hz. The resolution is typically 1 dB, which is sufficient for most practical applications, while the accuracy is ±2% of the measuring range plus ±0.5 dB, based on the reference tone of 94 dB at 1 kHz. The Sound Sensor therefore provides a precise and reliable basis for all acoustic measurements.
The specific technical features include a digital interface via RS-485 with Modbus RTU, which enables easy integration into existing systems. The sensor utilizes a high-quality condenser microphone with A-weighting, which takes into account the human sense of hearing. The response time is a maximum of 2 seconds. The Sound Sensor is suitable for wall mounting and has a weatherproof housing that is also designed for outdoor use. The device is particularly interesting for companies, authorities or research institutions that require continuous monitoring of noise sources, for example in production facilities, traffic controls or urban noise projects.... Read More |