| Description | Thickness Gauge with the unique swivelling probe / Easy measurements in hard-to-reach areas / For FE and nFE metals / Wireless interface for Windows, iOS and Android
The Thickness Gauge has a globally unique measuring probe that can be swiveled through 90°, allowing you to always carry out Thickness Gauge with the unique swivelling probe / Easy measurements in hard-to-reach areas / For FE and nFE metals / Wireless interface for Windows, iOS and Android
The Thickness Gauge has a globally unique measuring probe that can be swiveled through 90°, allowing you to always carry out precise coating thickness measurements. The Thickness Gauge with the compact, lightweight devices is barely larger than a measuring probe and is therefore ideal for on-site applications in hard-to-reach places. The handy metal housing is splash-proof to IP 64 for interference-free measurements in harsh environments. A coating thickness tester with flowing water protection is also available as an option. For a long service life with frequent measurements on rough surfaces, the measuring probe has a wear-resistant ruby probe pole.
With a single button and the self-explanatory, multilingual menu navigation, the Thickness Gauge is very easy to operate.
A Thickness Gauge is usually used in the quality assurance of coating processes. For example, to determine the paint thickness of a coating, when testing vehicles or steel structures or in fire protection (determining the coating thickness of steel doors). However, it is not only a Thickness Gauge, but can also be used to reliably measure rubber coatings, anodizing and galvanic coatings.
The Thickness Gauge uses a combined probe to measure insulating layers of paint, varnish, plastic, rubber, ceramic and galvanic coatings (excluding nickel) using the magnetic induction measuring method. The device is used on iron and steel substrates. It is also suitable for measuring insulating coatings (paint, plastic, etc.) using the eddy current method on non-ferrous metals such as aluminum, brass, copper, bronze and non-magnetic stainless steels in accordance with ISO 2178 and ISO 2360.
To further process your measurement data, you can connect your Thickness Gauge to mobile Android and iOS devices. Or you can communicate with a Windows PC. Wireless technology makes it possible. With the Lima Connect app, you can manage projects and allocate the measuring points on a photo. The measurement results can be statistically analysed and displayed graphically. The app for Android, iOS and Windows is free of charge.... Read More | The PCE-ATP 1-KIT with 100 swabs included is used to quickly and easily check the cleanliness of surfaces. The Hygiene Tester displays a measurement result on the large LC display after only 10 seconds. The Hygiene Tester's internal memory stores up to 10,000 measured data sets with time and date. The PCE-ATP 1-KIT with 100 swabs included is used to quickly and easily check the cleanliness of surfaces. The Hygiene Tester displays a measurement result on the large LC display after only 10 seconds. The Hygiene Tester's internal memory stores up to 10,000 measured data sets with time and date. The PCE-ATP 1 with the associated PCE-ATP SwapPens, allows a quick detection of food or microbiological residues on all surfaces in contact with the product as an effectiveness test of cleaning and disinfection measures. Quantitative determination of intracellular and extracellular adenosine triphosphate (ATP) is performed in the portable PCE-ATP 1. The measured data from the Hygiene Tester can be stored and further processed after the measurement. The Hygiene Tester is used in the hygiene control in pharmacy, medicine, gastronomy, wholesalers and more.... Read More | The illuminometer has a large measuring range of 0 … 400 lux. The illuminance is measured using an external silicon photodiode with a spectral filter. This means that the illuminometer can be positioned appropriately for every measuring task.
- Measuring range: 0,0 … 400,000 Lux
-
Resolution: 0.1 lux
-
The illuminometer has a large measuring range of 0 … 400 lux. The illuminance is measured using an external silicon photodiode with a spectral filter. This means that the illuminometer can be positioned appropriately for every measuring task.
- Measuring range: 0,0 … 400,000 Lux
-
Resolution: 0.1 lux
-
Lux and footcandle units
-
Micro-USB interface
-
Incl. software
-
Rechargeable battery
-
Data memory: 32,000 sets of readings
... Read More | Magnetometer / Magnetic Field Detector / Combined display / Memory for 10000 values / Wireless and USB-C interface / Incl. calibration standard
The Magnetometer / Magnetic Field Detector can be used to determine the relative magnetic permeability µr of materials and construction parts in the range Magnetometer / Magnetic Field Detector / Combined display / Memory for 10000 values / Wireless and USB-C interface / Incl. calibration standard
The Magnetometer / Magnetic Field Detector can be used to determine the relative magnetic permeability µr of materials and construction parts in the range between 1,000 and 5,000. Magnetic permeability, also known as magnetic conductivity, indicates how strongly a material can be magnetized. This Magnetometer / Magnetic Field Detector is ideal for material testing - especially for ferromagnetic material testing - in order to provide precise data for material testing NDT (non-destructive testing).
Areas of application include quality control of stainless steels, non-destructive material testing of construction parts, material selection for electron and ion physics equipment as well as for nuclear resonance devices, or the detection of material changes in highly stressed parts. The Magnetometer / Magnetic Field Detector has a graphic LCD touch panel with innovative user guidance and a resolution of 320 × 480 pixels.
The Magnetometer / Magnetic Field Detector supports all areas of permeability measurement with a flexible measured value memory, a combined digital and analogue display and peak value measurement. You can transfer the data to a Windows PC as well as to an Android or iOS app via the wireless interface. The Magnetometer / Magnetic Field Detector can be connected to an external power source in continuous operation via the USB interface.
You can check the accuracy of the measurement at any time using the calibration standard supplied with the permeability measuring device. The standard calibration standard has a value of µr ˜ 1.35. Calibration standards with reference values of µr ˜ 1.03 and µr ˜ 1.11 are also available.... Read More | The Voltmeter uses advanced conductance measurement to determine the condition of vehicle batteries quickly and accurately. This Voltmeter is suitable for all common lead-acid batteries, including standard, AGM, gel and EFB batteries, and enables direct detection of faulty batteries without prior The Voltmeter uses advanced conductance measurement to determine the condition of vehicle batteries quickly and accurately. This Voltmeter is suitable for all common lead-acid batteries, including standard, AGM, gel and EFB batteries, and enables direct detection of faulty batteries without prior full charging. In addition to the classic battery test, the Voltmeter offers comprehensive tests of the starter and charging system for 12 V and 24 V applications, including reliable ripple measurement for analyzing charging quality.
The measured results are clearly displayed on a 2.4-inch TFT color display with a resolution of 240 × 320 pixels, making all relevant data easy to read. The Voltmeter has a measuring range of 8V ... 30V DC and 100 ... 2000 A, and supports numerous international battery test standards such as CCA, BCI, CA, MCA, JIS, DIN, IEC, EN, SAE and GB. For efficient documentation, the test results can be transferred via the integrated USB interface and saved as a csv file. The measured value can also be transferred to an Android terminal device via a QR code.
The waveform display enables monitoring of the battery voltage and can also be transferred to the PC software. The Voltmeter is equipped with integrated reverse polarity protection, which ensures safe operation and prevents damage to the device. Designed for professional use in workshops, battery factories and vehicle service, the device operates reliably.... Read More |