| Description | The Condition Monitoring is certified in accordance with IEC 61672-1:2013, Class 1 and is ideally suited for professional use in noise monitoring. With a wide frequency range from 10 Hz to 20 kHz and extensive filter options, the device enables precise measurements in almost all areas of applicationThe Condition Monitoring is certified in accordance with IEC 61672-1:2013, Class 1 and is ideally suited for professional use in noise monitoring. With a wide frequency range from 10 Hz to 20 kHz and extensive filter options, the device enables precise measurements in almost all areas of application. The frequency weightings A, C and Z as well as the time weightings S (Slow), F (Fast) and I (Impulse) are supported in order to always ensure application-appropriate measurement behaviour.
The Condition Monitoring also impresses with its comprehensive connectivity: Ethernet, WiFi and USB Type-C enable flexible and uncomplicated data transfer. The internal 8 GB memory and optional SD cards with up to 64 GB provide sufficient storage capacity for extensive measurement campaigns. The high-resolution 4-inch TFT touch display ensures intuitive and convenient operation. Measured variables such as Lp, Lmax, Lmin, Leq, Lpeak, LN(1-99) and numerous other useful functions are displayed clearly and in detail, enabling professional detailed evaluation of the measurement results with this Condition Monitoring.
Its wide range of applications makes the Condition Monitoring the ideal solution for environmental noise monitoring, traffic noise analysis, noise exposure assessment, occupational health and safety monitoring and airport noise monitoring.
The software included in the scope of delivery extends the functionality considerably: it enables live data reception via Ethernet or WiFi, access to stored measurement data and the export of results as a PDF report or CSV file. In addition, the display of the measurement parameters can be freely configured within the software, allowing customisation to specific analysis requirements.... Read More | CO2 analyser with data memory for 5000 measuring points / Temperature, humidity / Export of the saved measurement data in CSV format / Battery and mains operation /
1/4 inch tripod mount / Measuring range (CO²) 0 ... 9999 ppm, (CO) 0 ... 1000 ppm
The CO2 analyser has a measuring range of 0 ... 9999CO2 analyser with data memory for 5000 measuring points / Temperature, humidity / Export of the saved measurement data in CSV format / Battery and mains operation /
1/4 inch tripod mount / Measuring range (CO²) 0 ... 9999 ppm, (CO) 0 ... 1000 ppm
The CO2 analyser has a measuring range of 0 ... 9999 ppm. In addition to the carbon dioxide measurement, the air quality detector also has a carbon monoxide (CO) sensor with a measuring range of 0 ... 1000 ppm and a temperature and humidity sensor. The air quality detector already covers a large range of measuring tasks. The air quality detector is therefore used, for example, in occupational safety to check the climatic conditions in office workplaces.... Read More | The Environmental Meter offers a reliable and precise solution for measuring liquid levels in a wide variety of applications. With a measuring range of 0 to 8 m / 0 … 26.2 ft H?O, the level gauge is ideally suited for use in deep wells, rivers, lakes, canals, reservoirs, and coastal monitoringThe Environmental Meter offers a reliable and precise solution for measuring liquid levels in a wide variety of applications. With a measuring range of 0 to 8 m / 0 … 26.2 ft H?O, the level gauge is ideally suited for use in deep wells, rivers, lakes, canals, reservoirs, and coastal monitoring applications up to a water depth of 8 m / 26.2 ft. The high accuracy of ±0.5% FS ensures precise measurement results even under demanding conditions. Thanks to its robust design with a stainless steel housing and durable cable material, the Environmental Meter is resistant to abrasion, oil, acids, and alkalis.
The flexible submersible installation allows for use in both static and flowing media. The long-term stability of ±0.2% FS per year ensures consistently reliable measurement results. The display is operated with a supply voltage of 24 V DC and is designed for connection to sensors with a 4–20 mA output signal. It also features a 4–20 mA analogue output, which enables easy processing of the measured values in higher-level control systems.
Four alarm relays (ALL, AL, AH, AHH) are available for monitoring limit values, allowing individual switching points to be set for different liquid levels. All settings can be conveniently adjusted directly via the control buttons on the display, ensuring quick and easy commissioning. The Environmental Meter is ideally suited for applications in water management, wastewater treatment, irrigation, water diversion, and industrial liquid monitoring.... Read More | The portable Health & Safety - Surface Resistance Meter on the principle of a two-point pin probe and enables simple and reliable measurement of the surface resistivity of materials - without the need for a megohmmeter, electrometer or other high-voltage measuring devices.
Thanks to its slim and The portable Health & Safety - Surface Resistance Meter on the principle of a two-point pin probe and enables simple and reliable measurement of the surface resistivity of materials - without the need for a megohmmeter, electrometer or other high-voltage measuring devices.
Thanks to its slim and handy design, the device can be conveniently operated with one hand and is ideal for on-site testing or mobile use in production and laboratories. Despite its compact size, it delivers precise results for quickly assessing whether a material is insulating, dissipative or conductive.
The Health & Safety - Surface Resistance Meter uses gold-plated, spring-loaded electrodes that ensure excellent contact with a wide variety of surfaces and minimize contact resistance. All electrodes are replaceable ATE quality pogo pin probes, made from beryllium copper with a hard gold plating of at least 60 microinches - robust, durable and precise.
The two-point probe head is directly connected to an integrated surface resistance measuring device, which measures the surface resistance at a test voltage of approx. 9 volts. The measurement results are shown on a colored LED display. This allows the ESD properties of a material to be clearly recognized at a glance.
With its combination of precise technology, easy handling, compact design and clear LED display, this Health & Safety is the perfect solution for quick on-site testing, quality control and ESD compliance tests in production, laboratories and development.... Read More | The rain and snow Temperature Sensor is used for reliable detection of precipitation and is used to monitor weather conditions in environmental stations, for irrigation control systems or in industrial plants. The rain and snow Temperature Sensor enables a quick and reliable response to rain or snowThe rain and snow Temperature Sensor is used for reliable detection of precipitation and is used to monitor weather conditions in environmental stations, for irrigation control systems or in industrial plants. The rain and snow Temperature Sensor enables a quick and reliable response to rain or snow. The Temperature Sensor qualitatively detects the presence of precipitation via conductivity and condensation properties and provides the information digitally via RS-485 Modbus RTU and via a potential-free relay output, which can be used to directly switch external devices or controls.
The integrated relay output is designed as a normally open contact and provides galvanic isolation between the Temperature Sensor voltage and the switched circuit. This allows both low-voltage and mains voltage applications to be implemented. The maximum switching capacity of the relay is 250V AC at 1 A or 30V DC at 1 A, making the Temperature Sensor suitable for direct control of controllers, actuators or relays.
The supply voltage of the rain and snow Temperature Sensor is 24 to 30V DC. The compact, corrosion-resistant housing is IP65-rated and designed for surface mounting. An automatic heating function activates at lower temperatures below 0°C / 32°F ambient temperature and heats the Temperature Sensor surface to approximately 40°C / 104°F to prevent ice formation. This ensures that the rain and snow Temperature Sensor works reliably even in frosty conditions. It is mainly used by weather station operators, environmental researchers, in irrigation systems and in industrial applications where precipitation needs to be reliably detected and automated responses implemented. ... Read More |