| Description | Our robust socket square inserts are specially designed for use with impact wrenches and are ideal for demanding bolting applications. The range covers thread sizes from M16 to M48 and offers the right wrench sizes for a wide variety of applications.
These high-quality socket square inserts impress Our robust socket square inserts are specially designed for use with impact wrenches and are ideal for demanding bolting applications. The range covers thread sizes from M16 to M48 and offers the right wrench sizes for a wide variety of applications.
These high-quality socket square inserts impress with their high load-bearing capacity, precise fit, and long service life – perfect for professional use in industry and assembly.... Read More | The PM2.5 particulate matter monitor PCE-RCM 05 is used to continuously measure the particulate matter content at the workplace. The PCE-RCM 05 PM2.5 monitor displays PM2.5 particulate matter as well as temperature and humidity on the display. The measuring range of the PCE-RCM 05 monitor ranges The PM2.5 particulate matter monitor PCE-RCM 05 is used to continuously measure the particulate matter content at the workplace. The PCE-RCM 05 PM2.5 monitor displays PM2.5 particulate matter as well as temperature and humidity on the display. The measuring range of the PCE-RCM 05 monitor ranges from 0 ... 500 µg / m³ PM2.5. This makes the PM2.5 meter an optimal test instrument to constantly have an overview of the fine dust content. Below the large measured value display of the PM2.5 content, the PM2.5 monitor provides quick information about the air quality with the aid of pictograms.
The PCE-RCM 05 fine dust monitor is powered by a rechargeable battery. The LC display is illuminated and easy to read from any angle, for example when the meter is on a desk. In addition to the standard white lighting, the PM2.5 monitor switches the lighting to red in the event of an alarm.... Read More | An Environmental Meter is used to monitor the ozone concentration in the air and to measure temperature and humidity. The Environmental Meter detects ozone in the range of 0 ... 9.9 ppm with an accuracy of ±15% of the measured value. The temperature is measured between 0 ... 50°C / 32 ... An Environmental Meter is used to monitor the ozone concentration in the air and to measure temperature and humidity. The Environmental Meter detects ozone in the range of 0 ... 9.9 ppm with an accuracy of ±15% of the measured value. The temperature is measured between 0 ... 50°C / 32 ... 122°F with ±1°C / 1.8°F accuracy, the humidity in the range of 5 ... 95% with ±5% accuracy. The device has an audible alarm when the preset alarm value of 3 ppm is exceeded and displays all values on a 0.9 inch LCD display. Other features include standby mode, rechargeable lithium battery via USB-C, compact size and a wrist strap for mobile use.
The Environmental Meter is suitable for mobile use in homes, offices, workshops, small production areas or private applications where ozone pollution needs to be monitored. With its compact design, measurements can be taken directly on site, making the Environmental Meter a practical instrument for reliable monitoring of ozone, temperature and humidity. By combining the three measuring functions, the Environmental Meter provides all relevant information for fast and standardized environmental monitoring. ... Read More | The Sound Sensor is ideal for all applications where ambient noise or noise levels need to be monitored precisely. Whether in urban noise measurement stations, on factory floors, in schools or in research projects - this Sound Sensor provides reliable measured values to fulfil safety and comfort The Sound Sensor is ideal for all applications where ambient noise or noise levels need to be monitored precisely. Whether in urban noise measurement stations, on factory floors, in schools or in research projects - this Sound Sensor provides reliable measured values to fulfil safety and comfort requirements. The sensor covers a measuring range of 30 ... 120 dBA and operates in the frequency range from 20 ... 12500 Hz. The resolution is typically 1 dB, which is sufficient for most practical applications, while the accuracy is ±2% of the measuring range plus ±0.5 dB, based on the reference tone of 94 dB at 1 kHz. The Sound Sensor therefore provides a precise and reliable basis for all acoustic measurements.
The specific technical features include a digital interface via RS-485 with Modbus RTU, which enables easy integration into existing systems. The sensor utilizes a high-quality condenser microphone with A-weighting, which takes into account the human sense of hearing. The response time is a maximum of 2 seconds. The Sound Sensor is suitable for wall mounting and has a weatherproof housing that is also designed for outdoor use. The device is particularly interesting for companies, authorities or research institutions that require continuous monitoring of noise sources, for example in production facilities, traffic controls or urban noise projects.... Read More | A Thermometer is an indispensable safety device for detecting dangerous carbon monoxide concentrations indoors. It is used wherever CO can occur - for example in homes with gas boilers or fireplaces, in workshops with running engines and in boats, motorhomes or other enclosed spaces with combustion A Thermometer is an indispensable safety device for detecting dangerous carbon monoxide concentrations indoors. It is used wherever CO can occur - for example in homes with gas boilers or fireplaces, in workshops with running engines and in boats, motorhomes or other enclosed spaces with combustion appliances.
The Thermometer records CO values in the range from 0 ... 500 ppm with a high resolution of 1 ppm. The Thermometer also measures relative humidity and temperature, whereby the temperature display can also be switched to Fahrenheit. All measured values are shown on an easy-to-read 2-inch LC display with backlighting.
For even more convenience, the Thermometer has a standby mode that can be activated manually. If no input is made within 60 seconds, the display switches off automatically - but the device remains active. In the event of increased CO values, the Thermometer warns with a visual and acoustic alarm. This is supported by a traffic light function: green for 0 ... 100 ppm, orange for 101 ... 200 ppm and red for 201 ... 500 ppm. As soon as the limit value of 100 ppm is exceeded, an additional acoustic warning signal sounds to indicate a possible hazard. Thanks to the integrated lithium battery, which is conveniently charged via USB-C, the detector is particularly flexible to use.... Read More |