Like conventional microplate readers, multimode microplate readers detect reaction signals from microtiter plates in order to perform assays such as ELISA, protein detection, and drug screening assays. Unlike conventional plate readers, multimode microplate readers are able to perform two or more forms of detection allowing a single piece of equipment to perform a wider range of assays. This can increase throughput and efficiency, thus saving time and space in the lab. Important things to consider when purchasing a multimode microplate reader are the particular combinations of assays desired, ease of use, ability to add or remove functionality, and the unit price.
Find, compare, and request a quote for multimode microplate readers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |
| Company | Molecular Devices, LLC | Molecular Devices, LLC |
| Item | FlexStation 3 Benchtop Multi-Mode Microplate Reader | SpectraMax i3x Multi-Mode Microplate Reader |
| Citations | | |
| Figures | | |
| Catalog Number | FlexStation 3 | i3x |
| Price | | |
| Description | Automated pipetting ensures consistent performance over multiple assay conditions on a microplate.
The FlexStation® 3 Multi-Mode Microplate Reader measures absorbance, fluorescence intensity, fluorescence polarization, luminescence, and time-resolved fluorescence. Programmable liquid handling Automated pipetting ensures consistent performance over multiple assay conditions on a microplate.
The FlexStation® 3 Multi-Mode Microplate Reader measures absorbance, fluorescence intensity, fluorescence polarization, luminescence, and time-resolved fluorescence. Programmable liquid handling allows for perfectly timed, automated biochemical and cell-based assays. The reader adds up to three transfers of assay reagents from a 96- or 384-well source plate to enhance assay design using integrated fluidics.
Onboard pipettor - Integrated 8-channel or 16-channel pipettor increases assay flexibility by transferring reagents from 96 or 384 distinct wells in a source plate to the read plate.
Optimal assay excitation - Dual monochromators allow users to target the optimal assay excitation and emission wavelengths and eliminate the need to change expensive band pass filters between experiments.
Low volume applications - SpectraDrop™ Micro-Volume Microplate offers a high-throughput solution for low volume measurement, accelerating sample preparation time and increased productivity in DNA, RNA and protein research.
Robot integration - The FlexStation 3 reader can be integrated with all leading partner robots and with our out-of-the-box automation solution for savings on up-front integration time and resources.
Other features and benefits include: - - Enable more assay conditions
- Automate pipetting
- Validate your reader
... Read More | Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus Unlimited breadth of user-upgradeable application modules expands research capabilities.
The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes.
With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user-configurable detection modules, the reader provides you with the ability to explore cellular pathways and protein expression on one microplate reader.
User-configurable applications - User-configurable detection modules expand the reader’s detection capabilities to include AlphaScreen, Time-Resolved Fluorescence, HTRF, fast kinetics with injectors, western blot detection, and more.
No-stain cell analysis - The StainFree™ Cell Detection Algorithm for brightfield cell segmentation enables cell counting and confluency measurement without destructive stains, simplifying the cell counting workflow.
Multi-channel functionality - Two fluorescence detection channels on the MiniMax cytometer enable the analysis of cell viability or cell toxicity assays, including ratiometric assays like live-dead and transfection efficiency.
Cellular pathway analysis - Cell confluence and cell viability imaging, western blot analysis, and quantitation of nucleic acids and protein, can be captured on one reader.
Other features and benefits include: - Capture flash assays with ease
- Reduce background noise
- Increase fluorescence performance
... Read More |
| Reading Modes | Absorbance Photometric, Fluorescence Intensity, Fluorescence Polarization, Time-resolved Fluorescence, Luminescence | Absorbance, Fluorescence (top/bottom read), Luminescence (top read), Time-Resolved Fluorescence (top read), Fluorescence Polarization (top read), HTRF (top read), AlphaScreen (top read) |
| Optical System | Dual Monochromator | Spectral Fusion Illumination |
| Wavelength Range | 200 to 1000 nm (depending on mode) | 230 to 1000 nm |
| Plate Formats | 6 to 384 Well Platess | 6 to 1536 wells |
| Temperature Control | [RT + 2C] to 45C | 4°C above ambient to 45°C |
| Get Quote | | |