| Company | Molecular Devices, LLC | Molecular Devices, LLC | Molecular Devices, LLC | Molecular Devices, LLC | Molecular Devices, LLC |
| Item | SpectraMax iD3s and iD5e Multi-Mode Microplate Readers | SpectraMax iD3s and iD5e Multi-Mode Microplate Readers | SpectraMax L Microplate Reader | SpectraMax M Series Multi-Mode Microplate Readers | SpectraMax Paradigm Multi-Mode Microplate Detection System |
| Citations | | | | | |
| Figures | | | | | |
| Catalog Number | | | SpectraMax L | SpectraMax M | Inquire |
| Price | | | | | |
| Description | Inquire | Inquire | Flash and glow luminescence detection in an upgradeable platform.
The SpectraMax® L Microplate Reader measures flash and glow luminescence assays in both 96- and 384-well plates. It is upgradeable to include a barcode reader, programmable injectors, and dual-channel configurations for a 2-fold Flash and glow luminescence detection in an upgradeable platform.
The SpectraMax® L Microplate Reader measures flash and glow luminescence assays in both 96- and 384-well plates. It is upgradeable to include a barcode reader, programmable injectors, and dual-channel configurations for a 2-fold increase for medium throughput. The high sensitivity, low-noise photomultiplier tubes (PMTs), and variable-volume injector configuration make this reader ideal for fast kinetic assays requiring continuous monitoring during injection and measurement.
Reduced noise - Ultra-fast photon counting technology amplifies the PMT signal with a fast pulse amplifier. This reduced noise capability enables a higher signal-to-noise ratio and low crosstalk.
PMT calibration - The automatic PMT calibration method is based on readings of 4 internal LEDs at 395, 470, 527, and 570 nm. The manual PMT calibration method is based on readings of 4 wells from the assay.
Other features and benefits include: - Detect all samples
- Get 2-fold improvement in speed
- Automate injector workflows
... Read More | Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm Dual monochromators increase performance and assay flexibility.
The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. These robust readers have been placed in labs from Antarctica to the International Space Station.
With optimized reagents, validation tools, and industry-leading SoftMax® Pro Software, they provide consistent performance.
Patented optimization - The patented AutoPMT optimization of the SpectraMax M5 reader adjusts the fluorescence detector to each sample well's concentration and normalizes the raw data, extending the dynamic range of assays.
IQ/OQ/PM Services - Qualify Molecular Devices microplate readers in GLP or GMP environments with our IQ/OQ/PM Services to preserve the documentation of services in a compliant format that can be accessed remotely.
Validation tools - Extensive suite of validation tools reduces the cost and time of validation by 50% as compared to using multiple platforms to collect and analyze data.
Compliance software - SoftMax Pro GxP Software extends data acquisition and analysis solution into regulated laboratories working under GMP, GLP, and 21 CFR Part 11 for secure electronic records.
Other features and benefits include: - - Assay flexibility
- Better absorbance accuracy
- Increased throughput
... Read More | Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment - The detection cartridge utilizes an energy intensity optimization technique Z-height focusing is enabled for fast top- and bottom-reads for all read modes. By performing Z-height optimization, a lens is adjusted to address low volumes or varied well geometry.
Eliminate manual gain adjustment - The detection cartridge utilizes an energy intensity optimization technique allowing you to read up to seven logs of sample concentration in a single pass of a plate without manual gain adjustment.
Configuration changes in minutes - Adding new read modes is fast and simple with the detection cartridge system. Order additional detection cartridges as your application needs change, and install them by yourself in under two minutes.
Increased dynamic range and sensitivity - Use predefined reductions, columns, and summary formulas, or create custom calculations. Analyze EC50 and Z-factors to identify assay quality, and graph results with over 21 curve fit options.
Other features and benefits include: - Get automatic Z-height optimization
- Eliminate manual gain adjustment
- Tailor your data analysis
... Read More |
| Optical System | Hybrid filters and monochromator tunable in 1 nm increments | Hybrid filters and monochromator tunable in 1 nm increments | Filter-based | Monochromator | High Powered LED or Flash Lamp |
| Measuring Time | Abs: 28 s, FL: 21 s, Lumi: 21 s, TRF: 25 s, FP: 35 s (96-well) | Abs: 28 s, FL: 21 s, Lumi: 21 s, TRF: 25 s, FP: 35 s (96-well) | Inquire | Absorbance: 17 seconds (96) Fluorescence Intensity: 15 seconds (96) Lumi: 17 seconds (96), TRF: 15 seconds (96), FP:44 seconds (96) | Inquire |
| Wavelength Range | Abs: 230–1000 nm; FL Ex: 250–830 nm, Em: 270–850 nm; Lumi: 300–850 nm; TRF Ex: 350 nm, Em: 450–750 nm; FP: 300–750 nm | Abs: 230–1000 nm; FL Ex: 250–830 nm, Em: 270–850 nm; Lumi: 300–850 nm; TRF Ex: 350 nm, Em: 450–750 nm; FP: 300–750 nm | 380 to 630 nm | 200 - 1000 nm | 230 to 1000 nm |
| Plate Formats | 6 to 384-well plates | 6 to 384-well plates | 96 or 384 Well Plates | 6, 12, 24, 48, 96, 384 Well Plates | 6 to 1536-well |
| Get Quote | | | | | |