A moisture balance, also called a moisture analyzer, measures the amount of moisture in a substance. This is particularly helpful in food processing labs as the amount of moisture can be an indicator of freshness and quality for some foods. These analyzers are also commonly used in environmental, pharmaceutical, and materials science labs. There are several techniques that may be used to measure moisture. Some techniques used include measuring water vapor released following combustion of the sample, measuring the difference in weight after removal of moisture from the sample, and measuring the equilibrium of water vapor of the sample in a closed system. Some things to take into consideration when purchasing a moisture balance include capacity, precision, speed, method of measurement, software, and whether the samples to be measured come in solid or liquid form.
Find, compare, and request a quote for moisture balances across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |  |  |
| Company | PCE Americas Inc. | PCE Americas Inc. | PCE Americas Inc. | PCE Americas Inc. | PCE Americas Inc. |
| Item | Analytical Balance PCE-MA 110-ICA Incl. ISO Calibration Certificate | Material Tester PCE-GMM 15 | Moisture Analyser / Moisture Analyzer PCE-UX 3011HQD | Moisture Analyzing Balance PCE-MA 110 | PCE-UX 3081WQ Moisture Analyzer |
| Catalog Number | PCE-IT 110-ICA | PCE-GMM 15 | PCE-UX 3011HQD | PCE-MA 110 | PCE-UX 3081WQ |
| Price | | | | | |
| Description | PCE-MA 110 is an analytical balance or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying PCE-MA 110 is an analytical balance or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. The moisture analyzer's halogen-heated drying chamber is suitable for the testing and analysis of samples of materials such as wood, pellets, biomass, granules, feed, food products and pastes.
Thanks to an impressive resolution or readability of 0.01 g / 10 mg, the moisture analyzer can determine the smallest weight differences. The moisture analyzer also covers the full moisture content range, from 0 ... 100%, with a moisture content resolution or readability of 0.1%. Measurement values are displayed clearly on the large, easy-to-read LCD screen.
The moisture analyzer features an adjustable drying time (1 ... 99 minutes) and an adjustable drying temperature (+40 ... +199 °C). Up to 16 different drying profiles or programs can be stored to the memory of the moisture analyzer, ensuring a controlled, repeatable testing process for accurate results time after time. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight. ... Read More | Our portable Material Tester was developed to determine the moisture content of 25 different types of seed quickly, easily and precisely. The measuring range is typically between 3% and 80% moisture, depending on the type of grain, with a resolution of 0.1% and an accuracy of ±0.5%. The Our portable Material Tester was developed to determine the moisture content of 25 different types of seed quickly, easily and precisely. The measuring range is typically between 3% and 80% moisture, depending on the type of grain, with a resolution of 0.1% and an accuracy of ±0.5%. The required sample quantity is approx. 90 ml, which allows quick and uncomplicated use directly on site. The Material Tester works on a capacitive basis and utilizes the compression of the sample caused by filling and sealing to increase the measuring accuracy.
The device has an alarm function for individually adjustable upper and lower limits, a display of minimum and maximum values and a function for calculating the average value. It also offers a data storage function for up to 240 measured values, a user-friendly keypad and automatic temperature compensation.
Thanks to the described compression, the Material Tester provides reliable measured values for checking storage and processing maturity. The grain moisture analyzer is suitable for professional applications where accurate moisture determination of grain is required.... Read More | Moisture Analyser / Moisture Analyzer for high temperatures up to max. 600°C / weighing range 200 g / adjustable heating temperature / 4-inch LC display / GLP-compliant printout of all data / software (optional)
Our Moisture Analyser / Moisture Analyzer for temperature-insensitive materials is Moisture Analyser / Moisture Analyzer for high temperatures up to max. 600°C / weighing range 200 g / adjustable heating temperature / 4-inch LC display / GLP-compliant printout of all data / software (optional)
Our Moisture Analyser / Moisture Analyzer for temperature-insensitive materials is suitable for various applications in raw material extraction, production, processing, research and recycling. With a maximum sample weight of 200 g and a high measuring resolution of 0.001 g, the Moisture Analyser / Moisture Analyzer enables precise moisture measurement.
The balance works on the principle of drying with simultaneous weighing. During drying, the weight loss is continuously recorded and displayed as a percentage of the total mass. With a heater output of 375 W and an adjustable heating temperature of 105 °C to 600 °C, the Moisture Analyser / Moisture Analyzer ensures quick and flexible drying of the samples. For measurement evaluation, the device offers various parameters such as % moisture, % dry mass, % moisture bd as well as g residual weight / kg and residual weight, which enable the sample to be analysed.
The functions include an automatic power-off function which stops the drying process when the constant weight is reached. The automatic power-off can be set to three criteria: start of sampling, sampling interval and weight loss per sampling interval. This allows a high degree of flexibility in controlling the drying process. There is also a timer that can be set from 1 to 180 minutes.
Our device is also equipped with a menu lock that prevents accidental adjustment of the parameters. The menu can be locked using a PIN whereas the CAL menu item remains available.
The balance also has a programme memory with up to 9 memory locations to store and quickly call up different drying profiles.
The moisture analyser balance offers GLP-compliant output of all data via Data Bridge. Intermediate values can be printed at individually adjustable intervals, if required. In addition, all data is transmitted via the serial RS-232 interface and USB. The printer can be deactivated, if required. Data can be transferred to a PC via a software which must be purchased separately.
The balance also has a 4-digit device ID for unique identification of the device, which enables precise allocation of the measurement data.
Our Moisture Analyser / Moisture Analyzer is suitable for temperature-insensitive materials and can be used in various areas. These include building materials such as cement, concrete and gravel, the chemical industry with powders, granulates and pastes as well as sewage treatment plants for analysing sewage sludge.... Read More | PCE-MA 110 is a halogen moisture balance that functions on the gravimetric or loss on drying (LOD) principle. The moisture balance uses the halogen method to dry the material sample. The moisture balance determines moisture content based on the weight difference before and after the drying procedurePCE-MA 110 is a halogen moisture balance that functions on the gravimetric or loss on drying (LOD) principle. The moisture balance uses the halogen method to dry the material sample. The moisture balance determines moisture content based on the weight difference before and after the drying procedure. Calibration of the moisture balance can be performed at any time using the automatic calibration function and the included 100 g weight.
Features:- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
-
Weighing resolution or readability: 0.1 g / 10 mg
-
Moisture content measuring range: 0 ... 100%
-
Moisture content resolution or readability: 0.1%
-
Adjustable drying time and temperature
-
Memory stores up to 15 drying profiles
... Read More | Inquire |
| Method | Inquire | Inquire | Inquire | Loss on drying | Inquire |
| Measuring Range | Inquire | Inquire | Inquire | 0 to 100% humidity, 0.01 to 100 g | Up to 400 g |
| Temperature Range | Inquire | Inquire | Inquire | 40 to 199°C, 104 to 390°F, adjustable | 105 to 360 °C |
| Minimum Display | Inquire | Inquire | Inquire | Inquire | 20 g |
| Get Quote | | | | | |