A chemical fume hood protects lab workers by venting solvent fumes and other harmful gases out of the laboratory and the indoor room air. Air flows into the cabinet beneath a movable sash at the front, and carries fumes up and out through the vent. Bypass fume hoods have an additional air intake above the sash which minimizes disruption of air flow in the work area due to movements in and out of the hood. Options in chemical fume cabinets now include energy efficient low flow fume hoods and hoods with an outdoor air intake (also known as auxiliary fume hoods) to avoid venting conditioned room air. Chemical fume hoods designed for specialized uses such as working with radioisotopes or perchloric acid are also available.
Click here for
Ductless Fume Hoods
|  |  |  |  |
| Company | TopAir Sytems Inc. | TopAir Sytems Inc. | TopAir Sytems Inc. | TopAir Sytems Inc. |
| Item | Educational Polypropylene Fume Cupboard with Full Transparency | Hybrid – Laminar Airflow Fume Hoods | Metal Fume Cupboard | Opioid Evidence Handling Workstation Kit |
| Catalog Number | FH-120-250-PP-CB | FH-120-HCV / FH-150-HVC / FH-180-HVC / FH-200-HVC / FH-250-HVC | FH-090/FH-120 / FH-150 / FH-180/FH-200 AND ANY SIZE PER REQIRE | CF-060-OP / CF-090-OP / CF-120-OP / CF-150-OP / CF-180-OP |
| Price | | | | |
| Size(s) | Inquire | Varies with model | Inquire | Inquire |
| Type | Inquire | Fume Cupboard | Fume Cupboard | Inquire |
| Exterior Dimensions | Inquire | (WxDxH) 1200 x 850 x 2320 mm to 2500 x 850 x 2320 mm (47.3 x 33.4 x 91.3 in. to 98.4 x 33.4 x 91.3 in.) | Varies with model | Varies with model |
| Interior Dimensions | Inquire | Inquire | Varies with model | Inquire |
| Depth | Inquire | 23.6 to 24.8 in. | 31.5 in. | Inquire |
| Description | Topair’s Educational Fume Hood has transparent sides and a transparent back for 360° visibility, serving educational sessions.
Topair’s Polypropylene Fume Cupboards are made of high-quality non-corrosive polypropylene with excellent chemical resistance. Polypropylene increases the product’s tensile Topair’s Educational Fume Hood has transparent sides and a transparent back for 360° visibility, serving educational sessions.
Topair’s Polypropylene Fume Cupboards are made of high-quality non-corrosive polypropylene with excellent chemical resistance. Polypropylene increases the product’s tensile strength and improves its thermal characteristics.
The Polypropylene Fume Cupboards protect laboratory staff from noxious fumes released by acids, dangerous gas and organic solutions – materials and acids which regular steel hoods may not withstand.
Harmful and unpleasant chemical fumes are removed from the controlled environment to facilitate a safe and pleasant work environment. The Fume Cupboard channels chemical vapors out of the building using an external fan installed on the roof or on an external wall.
The cupboards are designed for work with heavy chemicals, and have been independently tested to meet the requirements of EN-14175, ASHRAE 110-1995 standards.... Read More | TopAir’s Laminar Airflow Fume Hoods offer clean bench functionality. They are made of high-quality non-corrosive polypropylene with excellent chemical resistance.
The product is equipped with a dual airflow system: - Supply system with a pre-filter, HEPA filter and a fan that creates laminar down-
TopAir’s Laminar Airflow Fume Hoods offer clean bench functionality. They are made of high-quality non-corrosive polypropylene with excellent chemical resistance.
The product is equipped with a dual airflow system: - Supply system with a pre-filter, HEPA filter and a fan that creates laminar down-flow towards the working area.
- Exhaust system that needs to be connected to a ducting system with an outdoor fan. Both inflow and downflow (100% of the air) are channeled to the exhaust system.
Structure: - 8 mm welded polypropylene with high chemical resistance
- Polypropylene worktop – stainless steel optional.
- 5 mm front safety glass window with counterweight system
- Lower vented base cabinet made of polypropylene
- Air ventilation areas include perforations on the front and side area of the worktop and the grille at the rear.
Features: - 10.1” color touchscreen display
- VAV with air flow alarm and display
- Automatic laminar air velocity
- inflow is affected by the lab extracting system.
- automatic shutdown system for the down-flow when inflow system fails
- Clean bench functionality
- Cleanliness level – Class 100/ISO 5
- 800 lux LED lighting separated from the work area
- Includes polypropylene lower base cabinet
- Optional: sink/water tap/gas tap/ vacuum tap/electric sockets
- CE certified
... Read More | TopAir’s Metal Fume Hoods protect laboratory staff from noxious fumes when working with dangerous gases, organic solvents, etc. The fume hood channels chemical vapors out of the building using an outdoor fan installed on the roof or on an external wall. The hoods are EN-14175 / CE / ASHRAE 110-TopAir’s Metal Fume Hoods protect laboratory staff from noxious fumes when working with dangerous gases, organic solvents, etc. The fume hood channels chemical vapors out of the building using an outdoor fan installed on the roof or on an external wall. The hoods are EN-14175 / CE / ASHRAE 110-1995 certified.
Structure: - Metal epoxy-coated paint
- The internal lining is made of 5 mm HPL
- Ceramic worktop is included – optional materials include stainless steel, polypropylene, epoxy, and HPL
- 5 mm front safety glass window with counterweight system
- Lower vented base cabinet made of epoxy-painted metal
- Air ventilation from both the top and rear panels
FEATURES - Basic control system is a 7” color touch screen controlling lighting and power outlets
- Optional upgrades to control systems:
- AFA system – includes a 7” screen with air velocity display and alarm
- VAV system includes a 10.1” screen with automatic air velocity control (installed and included VFD), temp & humidity display
- Active system has a 10.1” screen with an energy saver that includes automatic sash motion with the proximity sensing system
*An active system dramatically reduces energy costs - 800 lux LED lighting separated from the work area (option for explosion-proof light)
- Optional accessories such as taps, sinks, sockets, scaffolding, and an outdoor fan
- EN-14175, ASHRAE 110-1995, CE certified
... Read More | TopAir’s Opioid Evidence Handling Workstation offer dual functionality by providing both fume containment and precise weighing capabilities. The stable cabinets are designed for accurate measurements of powders and chemicals by delivering a weight precision up to four decimal places. TopAir’s Opioid Evidence Handling Workstation offer dual functionality by providing both fume containment and precise weighing capabilities. The stable cabinets are designed for accurate measurements of powders and chemicals by delivering a weight precision up to four decimal places.
- Dual ULPA filter The ULPA filter includes a main filter and a secondary back up filter. It removes powders and particles with an efficiency of 99.9995 @ 0.3µm and provides reassurance to the to the lab staff.
- Vacuum system for efficient residue collection The vacuum system is an excellent instrument to collect residues of powders from the working surface and channel them to the ULPA filter.
- Filter integrity test after production (D.O.P) This test provides reassurance to lab staff about air quality and contamination control in the laboratory environment
... Read More |
| Quantity | EA | EA | EA | EA |
| Get Quote | | | | |