A chemical fume hood protects lab workers by venting solvent fumes and other harmful gases out of the laboratory and the indoor room air. Air flows into the cabinet beneath a movable sash at the front, and carries fumes up and out through the vent. Bypass fume hoods have an additional air intake above the sash which minimizes disruption of air flow in the work area due to movements in and out of the hood. Options in chemical fume cabinets now include energy efficient low flow fume hoods and hoods with an outdoor air intake (also known as auxiliary fume hoods) to avoid venting conditioned room air. Chemical fume hoods designed for specialized uses such as working with radioisotopes or perchloric acid are also available.
Click here for
Ductless Fume Hoods
|  |  |  |  |
| Company | AirClean Systems | AirClean Systems | AirClean Systems | AirClean Systems |
| Item | AC600 Series Ductless Chemical Fume Hoods | 200 Series Ductless Rotary Evaporator Enclosures | AirMax® Fume Hood with Wet Fume Scrubber | AirMax® Total Exhaust Polypropylene Fume Hood |
| Catalog Number | AC632A / AC632TA / AC632TAS / AC648A / AC648TA / AC648TAS | AC23824A | AC3030TE / AC4030TE / AC5030TE / AC6030TE / AC8030TE | AC3030TE / AC4030TE / AC5030TE / AC6030TE / AC8030TE |
| Price | | | | |
| Size(s) | 32 and 48 in | 38 in. | 36, 48, 60, 72 and 96 in. | 36, 48, 60, 72 and 96 in |
| Type | Ductless | Ductless, Application-Specific | Polypropylene/ Polycarbonate | Polypropylene |
| Exterior Dimensions | varies with model | (WxDxH) 38 x 24 x 48 in. | varies with model | varies with model |
| Interior Dimensions | varies with model | (WxDxH) 37 x 21 x 38 in. | varies with model | varies with model |
| Depth | 25 in. | 24 in. | Inquire | Inquire |
| Description | Designed to provide a low cost chemical hood solution for protection of the operator and environment from toxic vapors, gases, fumes, and particulate. The AC600 Series ductless chemical workstation features the use of molded thermoplastics configured for a variety of common applications. Smaller in Designed to provide a low cost chemical hood solution for protection of the operator and environment from toxic vapors, gases, fumes, and particulate. The AC600 Series ductless chemical workstation features the use of molded thermoplastics configured for a variety of common applications. Smaller in size, it makes an excellent portable fume hood for the classroom or laboratory.
Standard Features - AirSafe™ automatic safety controller
- Integral base with deep spill lip
- No ducting required
- Minimal installation - plugs directly into a standard 110V or 220V electrical outlet Extremely quiet operation < 49db="" />
- All thermoplastic construction with application specific sash, base and enclosure material
- Available in “low-profile” or tall version 32” or 48” widths with nominal 24” depth
- UL, CSA and CE listed
Safety Features - The chemical fume hood filter and electronics are located above the work area, eliminating the chance of a chemical spill entering these sensitive areas.
- The brushless, sparkless motor is post-filter.
- The deep base effectively contains accidental spills.
- The low airflow alarm warns user both visually and audibly.
- Filter safety lockout to ensure correct filter replacement.
... Read More | Operator exposure to chemical fumes and vapors has long been a concern when using the rotary evaporator. Many laboratories simply place the rotary evaporator into a standard exhaust hood, which takes up valuable space, that could be used for other critical laboratory manipulations.
The AirClean® Operator exposure to chemical fumes and vapors has long been a concern when using the rotary evaporator. Many laboratories simply place the rotary evaporator into a standard exhaust hood, which takes up valuable space, that could be used for other critical laboratory manipulations.
The AirClean® Systems 200 Series Rotary Evaporator Enclosure is designed for use with Heidolph* and Büchi* Rotary Evaporator models.
Features - Microprocessor controller — constantly monitors airflow
- Gas detector monitors and alerts when filter change is necessary
- Integral base with deep spill lip
- Application specific construction materials
- Extremely quiet operation <49 dB
- Horizontal sliding access doors for easy operation of rotary evaporator
- No ducting required
- Space-saving design (38”W x 24”D)
- Safely encloses rotary evaporator, vacuum pump and waste bottle
- Simple bonded carbon filter replacement — no dust!
... Read More | AirMax, with wet fume scrubber, is a total solution for minimizing personnel, ductwork and environmental exposure to caustic acid gases. Contaminated air passes through the scrubber’s water-washed contact media before being exhausted. The water used during the scrubbing process is captured in the AirMax, with wet fume scrubber, is a total solution for minimizing personnel, ductwork and environmental exposure to caustic acid gases. Contaminated air passes through the scrubber’s water-washed contact media before being exhausted. The water used during the scrubbing process is captured in the holding tank and recirculated. An optional pH dosing system can be added to neutralize acids captured during the scrubbing process.... Read More | AirClean® Systems AirMax™ total exhaust polypropylene fume hoods are manufactured from all-white, structural polypropylene. Polypropylene offers excellent chemical resistance. AirMax™ has a seamless design and allows for NO MORE RUST!
AirClean® Systems AirMax™ total exhaust polypropylene AirClean® Systems AirMax™ total exhaust polypropylene fume hoods are manufactured from all-white, structural polypropylene. Polypropylene offers excellent chemical resistance. AirMax™ has a seamless design and allows for NO MORE RUST!
AirClean® Systems AirMax™ total exhaust polypropylene fume hoods are standard bypass design. The standard bypass AirMax™ exhausts a constant volume of air, regardless of sash position.
A microprocessor controller monitors face velocity and displays the real-time airflow on the LCD screen in linear feet per minute.
Features - Flame-retardant polypropylene seamless interior
- Vertical sliding safety glass sash
- Variety of base cabinets available to compliment each AirMax™
- AirMax™ microprocessor controller
- Built-in vapor-proof fluorescent light
- Easy-access utilities panel for operation and maintenance
- All contact surfaces are constructed of polypropylene - “NO MORE RUST”!
- Flame-retardant polypropylene interior - higher temperature working range than fiberglass
- Non-hydroscopic - won’t absorb moisture
- Large volume spill basin with solid work surface
Safety Features - AirMax™ fume hoods have an advanced airfoil design that is important to the overall safety and performance of the fume hood. The rolled entry design incorporated into each AirMax™ hood prevents reverse flow and eddy currents from escaping the fume hood.
- AirMax™ exhaust hoods have a double sidewall construction which allows mounting of services and outlets on the posts.
- Containment of spills and heavy gases are easy with the AirMax™ total exhaust fume hood. A removable work surface exposes a spill basin that may be fitted with a drain for disposal of any spills.
- The rear baffle extends below the work surface to effectively remove any heavy gases or evaporation from a spill.
... Read More |
| Quantity | EA | Inquire | EA | EA |
| Get Quote | | | | |