Class II biological safety cabinets fall into four types (A1, A2, B1, B2), all of which protect the specimen, the user, and the environment from contamination. This is especially crucial for applications that require aseptic or particulate free conditions such as tissue culture experiments, and in toxicology work involving fumes and gases. All types of Class II biological safety cabinet have HEPA (high-efficiency particulate air) filters at their air supply and exhaust points.
For Type A1 and A2 Class II biological safety cabinets (A2 has a higher air velocity for greater protection), 70% of the airflow is recirculated within the cabinet while 30% of the air is exhausted (usually through the top). These cabinets do not protect against vapors and gases and, therefore, are best used for applications requiring sterile conditions without the need to work with volatile chemicals. However, when a Type A2 Class II biological safety cabinet is connected to a building’s exhaust system (through an optional canopy), trace amounts of volatile chemicals and radionuclides may be used.
For Type B1 and B2 Class II biological safety cabinets, more air is exhausted out of the cabinet (70% for B1, 100% for B2). These cabinets are best used for applications that require larger quantities of volatile chemicals and/or radionuclides (although limit restrictions may still apply). Type B Class II biological safety cabinets must be connected to the building’s exhaust system to protect the user from vapors and gases.
|  |  |  |
| Company | TopAir Sytems Inc. | TopAir Sytems Inc. | TopAir Sytems Inc. |
| Item | EN Biosafety Class II, Type A2 – Metal Version | Ecoline Biosafety Cabinet Class II, Type A2 | Polypropylene Biosafety Cabinet Class II Type A2 with IPMS |
| Catalog Number | BO-090 / 120 / 150 / 180-ME | ECO-BO-080-PP | BO-090 / 120 / 150 / 180-PP |
| Price | | | |
| Size(s) | Inquire | 3, 4, 5, and 6-foot | Inquire |
| Recirculated/Exhausted Air | Inquire | 70 % / 30 % | Inquire |
| Description | TopAir’s Class II, Type A2 Biological Safety Cabinet protects lab staff, the environment and sensitive work processes in which biological agents are applied. The cabinet offers a high level of contamination protection, based on two advanced HEPA H14 99.9995% @ 0.3 µm filters and features an airflow TopAir’s Class II, Type A2 Biological Safety Cabinet protects lab staff, the environment and sensitive work processes in which biological agents are applied. The cabinet offers a high level of contamination protection, based on two advanced HEPA H14 99.9995% @ 0.3 µm filters and features an airflow pattern of 70% downflow and 30% exhaust.
The cabinet is made of robust, epoxy coated metal structure with SS304 internals. The cabinet is operated using an elegant 10.1” intuitive touch screen control system that provides all of the device’s status information and alerts for unsafe critical conditions and
periodic maintenance reminders. Certification: all sizes are CE certified and BS EN 12469:2000 – 120 cm.
Structure:
Metal is epoxy coated
Internal lining is SS304, including the retractable one piece
worktop with spill tray
Front window of 6 mm triplex safety glass with manual
counterweight system... Read More | TopAir’s Class II, Type A2 Biological Safety Cabinet protects lab staff, the environment and sensitive work processes in which biological agents are applied. The cabinet offers a high level of contamination protection, based on two advanced HEPA H14 99.9995% @ 0.3 µm filters and features an airflow TopAir’s Class II, Type A2 Biological Safety Cabinet protects lab staff, the environment and sensitive work processes in which biological agents are applied. The cabinet offers a high level of contamination protection, based on two advanced HEPA H14 99.9995% @ 0.3 µm filters and features an airflow pattern of 70% downflow and 30% exhaust. The cabinet is made of robust, epoxy coated metal structure or polypropylene with SS304 internals.
The cabinet is CE certified and complies with EN 12469. Optional IPMS System: TopAir provides the world’s first Integrated Particle Monitoring system that includes a contamination alarm for ISO 5 clean verification.... Read More | TopAir’s Class II, Type A2 Biological Safety Cabinet protects lab
staff, the environment and sensitive work processes in which
biological agents are applied. The cabinet offers a high level of
contamination protection, based on two advanced ULPA U15
99.9995% @ 0.1 µm filters.
The cabinet is made of TopAir’s Class II, Type A2 Biological Safety Cabinet protects lab
staff, the environment and sensitive work processes in which
biological agents are applied. The cabinet offers a high level of
contamination protection, based on two advanced ULPA U15
99.9995% @ 0.1 µm filters.
The cabinet is made of robust, easily-cleaned anti-corrosive
polypropylene, an optimal material for clean rooms with its high
resistance to acids and other chemicals. Built in IPMS system:
TopAir provides the world’s first Integrated Particle Monitoring
system that includes a contamination alarm for ISO 5 clean
verification.
Structure:
8 mm welded polypropylene with high chemical resistance
Stainless Steel 304 worktop (SS316 optional)
Front window of 6 mm triplex safety glass with electric lift system
Side windows for better visibility... Read More |
| Get Quote | | | |