A lab water system (or laboratory water purification system) provides a consistent, pure, and adjustable source of water essential for many laboratory experiments. There are a variety of laboratory water systems, including deionized water systems, high flow lab water systems, reagent grade water systems, reverse osmosis water purification systems, and ultrapure water systems. A high and low flow (and ultra-pure) water system regulates a continuous water flow of up to 12L/minute, purifying the water with ion exchange systems and reverse osmosis to achieve up to 18.2 megOhms of resistance; equipped with 0.22-0.2 micron ultra filters to remove pyrogen, endotoxin, RNase and DNase. Laboratory water purification systems can also employ UV radiation to eliminate microorganisms. A laboratory water system can either draw water directly from the tap or from an accompanying reservoir. Lab water systems can be customizable, and meet NCCLS, ASTM, and cap specifications for Type 1 water.
Find, compare, and request a quote for lab water systems across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |
| Company | RephiLe Bioscience Ltd. | RephiLe Bioscience Ltd. |
| Item | Q Direct Pure water system | C Series Large Genie Water Systems |
| Catalog Number | RS0Q00000K / RS0Q0000TK / RS0QP0000K | RG0C04000 / RG0C08000 |
| Price | | |
| Description | Direct Pure Water System, Q generates ultrapure water from pure water, producing up to 2 liters of ultrapure water per minute. The upgraded Direct Pure water system offers greater convenience in every aspect of use. If a system with a remote dispenser is required, the Q Extended set is available.
Direct Pure Water System, Q generates ultrapure water from pure water, producing up to 2 liters of ultrapure water per minute. The upgraded Direct Pure water system offers greater convenience in every aspect of use. If a system with a remote dispenser is required, the Q Extended set is available.
Reliable Water Quality - Hourly automatic ultrapure water recirculation.
- Optimized flow path design ensures water purity, stability, and enhanced purification resin efficiency.
Designed for Simplicity - 2.4-inch touch screen with 8-language menu for real-time monitoring, manual/volumetric dispensing, and alerts.
- Tool-free plug-and-play installation and magnetic front panel for rapid consumable replacement.
- Leak-triggered shutdown and predictive consumable tracking ensure uninterrupted, risk-minimized operation.
Environmentally friendly&Low running cost - 2-year data traceability with LAN/USB export.
- Paperless data management and manufactured using green energy reduce carbon footprint.
- High-efficiency cartridges and compact, energy-saving design minimize operational costs and space requirements.
... Read More | Large Genie C benchtop high-output clinical water system produces up to 80 liters per hour of clinical laboratory reagent water. This mini high-output water purification system integrates proven water purification technologies with advanced control and monitoring functions to consistently supply Large Genie C benchtop high-output clinical water system produces up to 80 liters per hour of clinical laboratory reagent water. This mini high-output water purification system integrates proven water purification technologies with advanced control and monitoring functions to consistently supply reliable clinical-grade pure water from tap water. Product water can be directly fed to clinical analyzers or used via a remote water dispenser.
Reliable system performance for uninterrupted pure water supply: - Optimized work flow sequence. Comprehensive quality monitoring management
- Effective bacterial contamination prevention step prior to analyzer inlet
- Easy data traceability with automatic performance data backup for up to 2 years
- Mercury-free germicidal UVC LED lamps - online & Tank sanitization module. Environmentally friendly
Easy-to-use: - “1+N mode” - one water system can drive N units of dispenser (Up to 10 now and can be upgraded further more).
- Simple installation and maintenance with options to meet specific requirements of different analyzers
- RFID tracking of consumables, RO membranes and accessories to ensure optimal system performance and provide users with real-time operational intelligence
- Easy replacement of consumables- direct access from the front cover & quick-fit connections
Easy-to-control: - Equipped with multiple touch screens which are highly responsive, water-proof, latex glove friendly, and perfect for wet labs.
- Intuitive display with comprehensive data views
- The ability to export and print data and log-in requirements are built into the system
... Read More |
| Method | Double ion-exchange purification cartridges, final filter | RO, double ion-exchange cartridges, mercury-free UVC LED lamp, in-line filter |
| Output | Up to 2 L/min | Up to 2 L/min |
| Resistivity | 18.2 MΩ·cm @25°C | >10 MΩ.cm (Typically >16 MΩ.cm) @25°C |
| Dimensions | (WxDxH) 414 x 310 x 624 mm (16.3 x 12.2 x 24.5 in) | (WxDxH) 57 x 46 x 67 cm (22.5 x 18.2 x 26.4 in) |
| Get Quote | | |