Ultra high-performance liquid chromatography, UHPLC, uses columns packed with porous sub-2-µm particles (usually 1.8 µm) to vastly increase throughput and resolving power compared to conventional 5-µm columns. Pressures can surpass 19,000 psi. Limited solvent consumption, the ability to work under a broader pressure range, and lower band broadening are further enhancements. UHPLC’s 10× reduction in analysis time strengthens its popularity in areas including the pharmaceutical industry, food safety, and the clinical field.
The choice of detectors for use with UHPLC is wide-ranging, including UV-VIS, fluorescence, photodiode array, ELSD, quadrupole, and most recently, refractive index. For flexibility, many instruments offer the ability to run both conventional and UHPLC on one instrument. A final tip: When making the switch from HPLC to UHPLC, resist the temptation to overload the smaller columns.
Discover and compare Ultra High Performance Liquid Chromatographs:
Get Quote for All
Select up to 5 products from below to compare or request more information.
Agilent Technologies
- UV, FLD, RID
- 0.2–10 mL/min
- 600 bar (8700 psi)
Agilent Technologies
- DAD HS, DAD WR, VWD, MWD, FLD, FLD Spectra, RID, ELSD, MS
- 0.001–10 mL/min
- 600 bar (8702 psi)
Agilent Technologies
- DAD, VWD, FLD, RID, ELSD, MS
- up to 5 mL/min
- 800 bar
Agilent Technologies
- DAD, VWD, FLD, RID, ELSD, MS
- up to 5 mL/min
- 800 bar (11603 psi)
Agilent Technologies
- DAD, FLD, RID, MSD
- 0.05–5 mL/min
- 1300 bar
Hitachi High-Tech America, Inc.
- Diode array detector (DAD), UV-VIS detector
- 0.5–0.71 mL/min
- 140 MPa
SCIEX
- UV-VIS and photodiode array detectors
- 0.0001 to 3.0000 mL/min (145 to 15,200 PSI)
3.0001 to 5.0000 mL/min (145 to 11,600 PSI)
5.0001 to 10.0000 mL/min (145 to 3190 PSI) - 15,200 PSI (1048 bar)
SCIEX
- PDA, high-sensitivity PDA, MWD
- 0.001–5 mL/min
- 860–1240 bar
Shimadzu
- UV, PDA, ELSD, Fluorescence, RID, Conductivity
- 0.0001 – 3 mL/min (1.0 – 130 MPa); 3 – 5 mL/min (1.0 – 80 MPa); 5 – 10 mL/min (1.0 – 22 MPa)
- 130 Mpa
Shimadzu
- Photodiode array detector (PDA)
- 0.0001–2.0 mL/min
- 130 MPa
Shimadzu
- UV, PDA, ELSD, Fluorescence, RID, Conductivity
- 0.0001 – 3 mL/min (1.0 – 70 MPa); 3 – 5 mL/min (1.0 – 44 MPa); 5 – 10 mL/min (1.0 – 22 MPa)
- 70 Mpa
Shimadzu
- UV, PDA, ELSD, Fluorescence
- 0.0001 – 3.0000 mL/min (1.0 – 105 MPa); 3.0001 – 5.0000 mL/min (1.0 – 80 MPa); 5.0001 – 10.0000 mL/min (1.0 – 22 MPa)
- 105 Mpa
Shimadzu
- UV, PDA, ELSD, Fluorescence, RID, Conductivity
- 0.0001 – 3 mL/min (1.0 – 105 MPa); 3 – 5 mL/min (1.0 – 80 MPa); 5 – 10 mL/min (1.0 – 22 MPa)
- 105 Mpa
Thermo Fisher Scientific
- Charged Aerosol Detector (CAD), Diode Array Detector (DAD), Fluorescence Detector (FLD), Multiple Wavelength Detector (MWD), Variable Wavelength Detector (VWD), Refractive Index Detector (RI), Mass Spectrometer
- 0–10 mL/min
- 700 bar
Thermo Fisher Scientific
- Charged Aerosol Detector (CAD), Diode Array Detector (DAD), Fluorescence Detector (FLD), Multiple Wavelength Detector (MWD), Variable Wavelength Detector (VWD), Refractive Index Detector (RI), Mass Spectrometer
- 0–5, 0–8, or 0–10 mL/min (depends on pumps selected)
- 700–1500 bar (depends on configuration)
Thermo Fisher Scientific
- Charged Aerosol Detector (CAD), Diode Array Detector (DAD), Fluorescence Detector (FLD), Multiple Wavelength Detector (MWD), Variable Wavelength Detector (VWD), Refractive Index Detector (RI), Mass Spectrometer
- 0–5 or 0–8 mL/min (depends on pumps selected)
- 1000 or 1500 bar (depends on configuration)
Thermo Fisher Scientific
- Charged Aerosol Detector (CAD), Diode Array Detector (DAD), Fluorescence Detector (FLD), Multiple Wavelength Detector (MWD), Variable Wavelength Detector (VWD), Refractive Index Detector (RI), Mass Spectrometer
- 0–5, 0–8, or 0–10 mL/min (depends on pumps selected)
- 700, 1000, or 1500 bar (depends on configuration)
Thermo Fisher Scientific
- Charged Aerosol Detector (CAD), Diode Array Detector (DAD), Fluorescence Detector (FLD), Multiple Wavelength Detector (MWD), Variable Wavelength Detector (VWD), Refractive Index Detector (RI), Mass Spectrometer
- 0–5 or 0–8 mL/min (depends on pumps selected)
- 1500 bar
Thermo Fisher Scientific
- Inquire
- 8 mL/min
- up to 1000 bar (15,000psi)
Thermo Fisher Scientific
- Inquire
- 8 mL/min
- up to 1000 bar (15,000psi)
Thermo Fisher Scientific
- Inquire
- 8 mL/min
- Up to 1500 bar (22,000 psi)
Thermo Fisher Scientific
- Diode Array
- 8 mL/min
- up to 1000 bar (15,000psi)
Waters | Wyatt Technology
Waters | Wyatt Technology
KNAUER
- DAD, UV, MWD, RID, FLD, ELSD, MS
- up to 5 mL/min
- 1240 bar
KNAUER
- DAD, UV, MWD, RID, FLD, ELSD, MS
- 0.001-5 mL/min
- 1240 bar
Select up to 5 products from above to compare or request more information.