Thermogravimetric Analyzer (TGA Analyzer)

Thermogravimetric Analyzer (TGA Analyzer) Thermogravimetric analyzers measure changes in mass or weight in response to increases in temperature or time. These kinds of measurements can give valuable information about a material's thermal stability, response to oxidation, composition, decomposition kinetics, moisture content, and more. Thermogravimetric analyzers thus have applications for many types of studies such as materials science research, studies of reaction kinetics, and determining the durability of materials used to make space craft. Some things to consider when purchasing a thermogravimetric analyzer include the type of samples the machine is optimized for, sample weight, temperature range, ease of calibration, and analysis and cool down times.

Find, compare, and request a quote for thermogravimetric analyzers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Showing 24 of 24 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
TGA-FTIR Coupling
Bruker Optics
  • Temperature Range:
    Inquire
  • Weight Range:
    Inquire
  • Weight Resolution:
    Inquire
Citations:
(2)
TGA801 Thermogravimetric Analyzer
LECO
  • Temperature Range:
    up to 1000 °C
  • Weight Range:
    Inquire
  • Weight Resolution:
    Inquire
Citations:
(6)
TGM800 Thermogravimetric Moisture
LECO
  • Temperature Range:
    Inquire
  • Weight Range:
    Inquire
  • Weight Resolution:
    Inquire
Citations:
(2)
Discovery High Pressure HP TGA
TA Instruments – a division of Waters Corporation
  • Temperature Range:
    RT – 1100 °C
  • Weight Range:
    500 mg
  • Weight Resolution:
    0.1 µg
DynTHERM High Pressure TGA
TA Instruments – a division of Waters Corporation
  • Temperature Range:
    RT to 1100 °C
  • Weight Range:
    20 g
  • Weight Resolution:
    10 µg
Thermogravimetric TGA 55
TA Instruments – a division of Waters Corporation
  • Temperature Range:
    Ambient to 1000 °C
  • Weight Range:
    Dynamic Weighing Range 1000 mg
  • Weight Resolution:
    0.1 µg
Citations:
(90)
Thermogravimetric TGA 550
TA Instruments – a division of Waters Corporation
  • Temperature Range:
    Ambient to 1000 °C
  • Weight Range:
    Dynamic Weighing Range 1000 mg
  • Weight Resolution:
    0.1 µg
Citations:
(144)
Thermogravimetric TGA 5500
TA Instruments – a division of Waters Corporation
  • Temperature Range:
    Ambient to 1200 °C
  • Weight Range:
    Dynamic Weighing Range 1000 mg
  • Weight Resolution:
    <0.1 µg="">
Citations:
(119)
STA 509 Jupiter Classic Simultaneous Thermal Analyzer
NETZSCH-Gerätebau GmbH
  • Temperature Range:
    RT to 1600°C
  • Weight Range:
    35 g
  • Weight Resolution:
    0.1 µg
STA 509 Jupiter Select Simultaneous Thermal Analyzer
NETZSCH-Gerätebau GmbH
  • Temperature Range:
    -150°C to 2400°C
  • Weight Range:
    35 g
  • Weight Resolution:
    0.1 µg
STA 509 Jupiter Supreme Simultaneous Thermal Analyzer
NETZSCH-Gerätebau GmbH
  • Temperature Range:
    -150°C to 2400°C
  • Weight Range:
    5 g
  • Weight Resolution:
    0.025 µg
TG 309 Libra Classic Thermogravimetric Analyzer
NETZSCH-Gerätebau GmbH
  • Temperature Range:
    RT (10°C) to 1025°C
  • Weight Range:
    2000 mg
  • Weight Resolution:
    50 ng
TG 309 Libra Select Thermogravimetric Analyzer
NETZSCH-Gerätebau GmbH
  • Temperature Range:
    RT (10°C) to 1025°C / 1100°C
  • Weight Range:
    2000 mg
  • Weight Resolution:
    20 ng
TG 309 Libra Supreme Thermogravimetric Analyzer
NETZSCH-Gerätebau GmbH
  • Temperature Range:
    RT (10°C) to 1100°C
  • Weight Range:
    2000 mg
  • Weight Resolution:
    10 ng
Pyris STA 9 Simultaneous Thermal Analyzer
PerkinElmer
  • Temperature Range:
    20 to 1100°C
  • Weight Range:
    1500 mg
  • Weight Resolution:
    Inquire
Inquire
Pyris TGA 9 Thermogravimetric Analyzer
PerkinElmer
  • Temperature Range:
    15 to 1100°C
  • Weight Range:
    1500 mg
  • Weight Resolution:
    0.1 µg
Inquire
STAvesta Simultaneous TG-DSC Thermal Analyzer
Rigaku Corporation
  • Temperature Range:
    RT to 1,100°C (Standard/Sample observation); RT to 1,500°C (High temperature/Indirect heated); RT to 1,400°C (HUM); -40 to 700°C (Refrigerated cooling)
  • Weight Range:
    ±500 mg
  • Weight Resolution:
    <10 µg (up to 1,000°C); <20 µg (up to 1,400°C)
LABSYS evo STA
Setaram Instrumentation
  • Temperature Range:
    Room temperature to 1150°C or Room temperature to 1600°C (two furnace versions)
  • Weight Range:
    +/-1000 mg (large range); +/-200 mg (small range)
  • Weight Resolution:
    0.2 µg (large range); 0.02 µg (small range)
Sensys EVO TG-DSC
Setaram Instrumentation
  • Temperature Range:
    Ambient to 830°C; with liquid nitrogen accessory: -120 to 200°C
  • Weight Range:
    +/-200 mg
  • Weight Resolution:
    0.02 µg (standard); 0.002 µg (high resolution)
SETLINE TGA
Setaram Instrumentation
  • Temperature Range:
    RT to 1100°C (max 900°C under helium)
  • Weight Range:
    +/-20 mg (small range); +/-200 mg (large range)
  • Weight Resolution:
    Inquire
SETSYS Evolution TGA
Setaram Instrumentation
  • Temperature Range:
    -150 to 2400°C (5 furnace versions: Cryo -150 to 400°C, 12: ambient to 1200°C, 16: ambient to 1600°C, 18: ambient to 1750°C, 24: ambient to 2400°C)
  • Weight Range:
    +/-200 mg (35 g balance); +/-2 g (100 g balance)
  • Weight Resolution:
    0.03 µg (35 g balance); 0.3 µg (100 g balance)
SETSYS Evolution TGA-DTA/DSC
Setaram Instrumentation
  • Temperature Range:
    -150 to 2400°C (5 furnace versions; DSC up to 1600°C, DTA up to 2400°C)
  • Weight Range:
    +/-200 mg (35 g balance); +/-2 g (100 g balance)
  • Weight Resolution:
    0.03 µg (35 g balance); 0.3 µg (100 g balance)
THEMYS
Setaram Instrumentation
  • Temperature Range:
    Ambient to 2400°C (TGA/DTA/TG-DTA/TMA); Ambient to 1600°C (DSC/TG-DSC)
  • Weight Range:
    +/-5 to +/-3000 mg (depending on balance option)
  • Weight Resolution:
    0.00059 µg (High Sensitivity), 0.023 µg (High Versatility), 0.03 µg (High Capacity)
NEXTA STA Simultaneous Thermogravimetric Analyzer
Hitachi High-Tech Corporation
  • Temperature Range:
    Ambient to 1,500°C (STA300); Ambient to 1,100°C (STA200); Ambient to 1,000°C (STA200RV)
  • Weight Range:
    Inquire
  • Weight Resolution:
    Inquire
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • <<
  • >>
  • Bruker Optics
  • Hitachi High-Tech Corporation
  • LECO
  • NETZSCH-Gerätebau GmbH
  • PerkinElmer
  • Rigaku Corporation
  • Setaram Instrumentation
  • TA Instruments – a division of Waters Corporation

Review Laboratory Products

Review the laboratory equipment you use and receive an Amazon gift card!

Submit a Review
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!

Note: Labcompare disclaims any information on this site.