Time of Flight Mass Spectrometer (TOF MS)

Time-of-flight mass spectrometers (TOF MS) do exactly what their name suggests: determine an ion’s mass-to-charge ratio (m/z) based on how long it takes for that ion to travel down the instrument’s “flight tube” and reach the detector. Frequently, though not exclusively coupled to matrix-assisted laser desorption ionization (MALDI) sources, TOF MS come in a variety of configurations, including a single-stage time-of-flight mass spectrometer, a multi-stage TOF/TOF, and even a hybrid quadrupole-TOF (Q-TOF) instrument; the latter two enable MS/MS applications. Often, time-of-flight mass spectrometers contain two detectors: a linear detector at the end of the flight tube, and a “reflector” detector, which captures ions that were redirected back towards the source by a “reflectron.” The reflectron serves two purposes: correcting for discrepancies in initial kinetic energy of identically sized molecules (which would cause them to reach the detector at different times and thus, have different apparent m/z values) and lengthening the flight path, improving resolution.

Find, compare, and request a quote for time of flight mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Showing 6 of 6 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
Axima Assurance MALDI Time of Flight Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    MALDI
  • Mass Analyzer:
    TOF
  • Resolution:
    >5000 FWHM
  • Mass Range:
    1 kDa to 500 kDa
Citations:
(88)
Axima Confidence MALDI TOF Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    MALDI
  • Mass Analyzer:
    TOF
  • Resolution:
    5000 FWHM in linear mode; 15000 FWHM in reflectron mode
  • Mass Range:
    1 kDa to 500 kDa
Citations:
(147)
Figures:
(10)
Axima Performance MALDI TOF TOF Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    MALDI
  • Mass Analyzer:
    TOF/TOF
  • Resolution:
    >20,000 FWHM (Reflectron mode)
  • Mass Range:
    1 kDa to 500 kDa
Citations:
(310)
Figures:
(3)
LCMS-9030 Q-TOF Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, DUIS, Micro
  • Mass Analyzer:
    Quadrupole Time-of-Flight (Q-TOF)
  • Resolution:
    30,000 FWHM
  • Mass Range:
    m/z 10 to 40,000
Citations:
(91)
LCMS-9050 Q-TOF Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, DUIS, Micro
  • Mass Analyzer:
    Quadrupole Time-of-Flight (Q-TOF)
  • Resolution:
    Inquire
  • Mass Range:
    Inquire
Citations:
(2)
MegaTOF Megadalton MALDI Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    MALDI
  • Mass Analyzer:
    TOF
  • Resolution:
    180 to 200 kDa
  • Mass Range:
    0.01 to 1.5 Mda
Citations:
(5)
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
Shimadzu
Axima Confidence
5
10 Figures from 147 Publications
Shimadzu
Axima Performance
S8
3 Figures from 310 Publications
Showing 2 of 2 products
  • <<
  • >>
  • JEOL USA, Inc.
  • LECO
  • SCIEX
  • Shimadzu
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!