Time-of-flight mass spectrometers (TOF MS) do exactly what their name suggests: determine an ion’s mass-to-charge ratio (m/z) based on how long it takes for that ion to travel down the instrument’s “flight tube” and reach the detector. Frequently, though not exclusively coupled to matrix-assisted laser desorption ionization (MALDI) sources, TOF MS come in a variety of configurations, including a single-stage time-of-flight mass spectrometer, a multi-stage TOF/TOF, and even a hybrid quadrupole-TOF (Q-TOF) instrument; the latter two enable MS/MS applications. Often, time-of-flight mass spectrometers contain two detectors: a linear detector at the end of the flight tube, and a “reflector” detector, which captures ions that were redirected back towards the source by a “reflectron.” The reflectron serves two purposes: correcting for discrepancies in initial kinetic energy of identically sized molecules (which would cause them to reach the detector at different times and thus, have different apparent m/z values) and lengthening the flight path, improving resolution.
Find, compare, and request a quote for time of flight mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |
| Company | SCIEX | SCIEX |
| Item | ZenoTOF 7600 system | X500R QTOF system |
| Citations | | |
| Catalog Number | ZenoTOF 7600 | X500R QTOF |
| Price | | |
| Ionization Method(s) | APCI and ESI modes | Turbo V ion source with twin sprayer ESI probe and twin sprayer APCI probe |
| Mass Analyzer | TOF | QTOF |
| Resolution | Equal to or greater than 42,000 (FWHM) measured on the [M+6H]6+ charge isotope cluster for bovine insulin at m/z 956 | Equal to or greater than 42,000 (FWHM) measured on the (M+6H)6+ charge isotope cluster for bovine insulin at m/z 956 |
| Scanning Speed | up to 25 Hz (25 spectra per second) | Up to 25 Hz (25 spectra per second) |
| Mass Range | TOF: 40 kDa
Precursor Ion Selection: 5–2250 m/z | TOF: 40 kDa
Precursor Ion Selection: 5–2250 m/z |
| Description | A powerful leap in proprietary innovation, this high-resolution accurate mass system combines the power of Zeno trap pulsing with EAD fragmentation technology (electron activated dissociation) to uncover structural information, previously inaccessible, and drive the limits of quantification A powerful leap in proprietary innovation, this high-resolution accurate mass system combines the power of Zeno trap pulsing with EAD fragmentation technology (electron activated dissociation) to uncover structural information, previously inaccessible, and drive the limits of quantification achievable with accurate mass.... Read More | Engineered for standard biotherapeutic characterization analyses, the X500B QTOF system is a true benchtop instrument, with streamlined processing to get to a consistent, accurate view of your biologic. It is optimized for intact mass analysis, subunit analysis as well as high-quality peptide Engineered for standard biotherapeutic characterization analyses, the X500B QTOF system is a true benchtop instrument, with streamlined processing to get to a consistent, accurate view of your biologic. It is optimized for intact mass analysis, subunit analysis as well as high-quality peptide mapping workflows.... Read More |
| Quantity | EA | EA |
| Get Quote | | |
Articles
- Expensive to Maintain, but Performs Great
- LECO and CDS Analytical Announce Relationship to Deliver Pyrolysis and High Performance GC-TOFMS
- Analysis of Wastewater Effluent Samples to Identify Toxic Chemicals Using the High-Resolution Agilent 7250 GC/Q-TOF
- Massbox® Mass Spectrometer
- Waters Combines Best-in-Class Performance, Versatility and Usability Technologies in New Xevo G2 Tof Benchtop System
- Waters Combines Best-in-Class Performance, Versatility and Usability Technologies in New Xevo G2 Tof Benchtop System
- Visit LECO at ASMS—Booth #125
- LECO Pittcon 2011 Posters Now Available
- ALMSCO International Highlights Its BenchTOF-dx for Improved Sensitivity at ASMS 2011
- PerkinElmer Launches AxION™ Mass Spectrometry Platform
- LECO Corporation to Host Free Webinar on Environmental Forensic Investigation
- LECO and ACD/Labs Collaborate for Software Support on New High Resolution TOFMS Systems
- Leco Corporation to Host Free Webinar On Identifying Ergogenic Aids and Metabolites in Urine
- LECO, Florida State University Partnership Benefits Future Fuels Research
- LECO and ACD/Labs Collaborate for Software Support on New High Resolution TOFMS Systems
- ThoMSon Mass Spectrometry Laboratory at Brazil’s University of Campinas Selected as Waters Center of Innovation
- IONICON celebrates 200 sold PTR-MS instruments
- Markes and ALMSCO International to jointly showcase high-sensitivity technology for trace-level aroma and fragrance profiling at Analytica 2012
- PerkinElmer Presents Latest Analytical Innovations at Analytica 2012
- AB SCIEX Announces Biologics Initiative
- Technical Presentations from Recent Shows Available from LECO
- LECO and Genedata Collaborate on Mass Spectrometry Data Analysis for High Resolution TOFMS Systems
- Online Training Now Available for LECO Separation Science Instrumentation
- LECO Corporation to Host Webinar on Dioxin Analysis
- Maintaining High Mass Resolution for Tissue Imaging with the JEOL SpiralTOF™
- New GC/TOF-Related Website Offers Analytical Chemists a Wealth of Information
- Business as Usual for Markes International as Schauenburg International Acquires a Majority Share
- LECO to Host Webinar on High Resolution GC-MS for Metabolomics Applications
- Chemical Ionization (HR-CI) Source Introduced by LECO for Pegasus® GC-HRT
- Pivot Park and Spinnovation Analytical join forces to provide analytical solutions at Pivot Park Life Sciences Community, Oss
- Agilent Technologies to Host Webinars on Food Safety and Quality
- Enhanced Analysis and Imaging Capabilities on Display at JEOL Pittcon Booth #2224
- AB SCIEX and LECO Partner to Offer Combined Solutions for GC/MS and LC/MS to Metabolomics Researchers
- New Chemical Ionization Application Notes from LECO
- LECO Announces Special Events at ASMS
- JEOL and Zoex Partnership Combines Comprehensive Two-Dimensional Gas Chromatography with High Sensitivity Mass Spectrometer
- Pegasus® HT GC-TOFMS
- Pegasus® 4D GCxGC-TOFMS: Comprehensive Two-Dimensional Gas Chromatography
- Chemical Ionization Source for Pegasus® GC-HRT
- Pegasus® GC-HRT (High Resolution TOFMS)
- Shimadzu's New MALDI-7090 TOF-TOF Mass Spectrometer Combines High Throughput, High Resolution and High Energy for the Ultimate in Tandem MS Capabilities
- AB SCIEX, Genedata & LECO Announce Partnership for New Cross-Platform Metabolomics Data Analysis Solution
- IONICON: The Leading PTR-MS Company Celebrates its 15th Anniversary
- LECO GCxGC Technology Used in Award-Winning Paper
- LECO to Host Webinar on GC-TOFMS Flavor Analysis
- Agalimmune Ltd Founded to Develop Immunotherapeutics for Cancer
- Forensic Mass Spectrometry
- Food Mass Spectrometry
- Cannabis Mass Spectrometry
- Analyzing Unknowns
- Next-Generation Software for Food and Forensic Laboratories
- Integrating GC/TOF Exposome Profiling and Genetic Disease Screening to Provide a Holistic Perspective on Honey Bee Health
- UCMR4, Microcystins Analysis, and High-Resolution Mass Spectrometry for Confidence in Identity Confirmation
- MALDI-TOF/TOF System Exceeds Your Expectations
- High quality and very accurate
- Buyers’ Guide: Best Buys for Mass Spectroscopy
- IONICON Launches the New Super-fast PTR-TOF 1000 Trace Gas Analyzer
- Pittcon Announces Highlights of Waters Symposium
- Researchers Discover That “Green” Household Cleaners Emit Just as Many Harmful Chemicals
- ‘Omics Research Dominates ASMS 2023
- ‘Hidden’ Pesticide Byproducts Found in Wild Birds of Prey
- Comprehensive Profiling of Environmental Contaminants in Surface Water Using High-Resolution GC/Q-TOF
- Contaminants Screening Using High-Resolution GC/Q-TOF and an Expanded Accurate Mass Library of Pesticides and Environmental Pollutants
- Short Chain Chlorinated Paraffins (SCCP) Analysis Using Negative Chemical Ionization (CI) and Low Energy EI by High-Resolution 7250 GC/Q-TOF
- Agilent to Present Food Science Data at AOAC: Pesticide Analysis, Gluten, Food Allergens, Whiskey
- Cerno Bioscience Announces Most Significant Upgrade of MassWorks™ Software Product
- Bruker Announces FDA Clearance to Market the MALDI Biotyper CA System
- More Data, Fewer Instruments: Simplifying the Battery Research Workflow
- Pre-screening Novel Psychoactive Substances to Speed Detection
- Pittcon Announces 2014 Editors' Awards: Journalists Select Gold, Silver and Bronze
- The Challenge of Tumor Heterogeneity in Personalized Medicine
- Child COVID-19 Breath Test Study IDs Potential Biomarkers
- Personal Products Comparable to Fossil Fuels in Urban Air Pollution
- Determination of Pain-Management Drugs in Human Urine Using “Flip-Flop” Chromatography and Time-of-Flight Mass Spectrometry
- Perspectives from ASMS 69: Part I