Time-of-flight mass spectrometers (TOF MS) do exactly what their name suggests: determine an ion’s mass-to-charge ratio (m/z) based on how long it takes for that ion to travel down the instrument’s “flight tube” and reach the detector. Frequently, though not exclusively coupled to matrix-assisted laser desorption ionization (MALDI) sources, TOF MS come in a variety of configurations, including a single-stage time-of-flight mass spectrometer, a multi-stage TOF/TOF, and even a hybrid quadrupole-TOF (Q-TOF) instrument; the latter two enable MS/MS applications. Often, time-of-flight mass spectrometers contain two detectors: a linear detector at the end of the flight tube, and a “reflector” detector, which captures ions that were redirected back towards the source by a “reflectron.” The reflectron serves two purposes: correcting for discrepancies in initial kinetic energy of identically sized molecules (which would cause them to reach the detector at different times and thus, have different apparent m/z values) and lengthening the flight path, improving resolution.
Find, compare, and request a quote for time of flight mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |
| Company | Shimadzu | Shimadzu |
| Item | LCMS-9050 Q-TOF Mass Spectrometer | MegaTOF Megadalton MALDI Mass Spectrometer |
| Citations | | |
| Catalog Number | LCMS-9050 | MegaTOF |
| Price | | |
| Ionization Method(s) | ESI, APCI, DUIS, Micro | MALDI |
| Mass Analyzer | Quadrupole Time-of-Flight (Q-TOF) | TOF |
| Resolution | Inquire | 180 to 200 kDa |
| Scanning Speed | Inquire | 15 sec/position |
| Mass Range | Inquire | 0.01 to 1.5 Mda |
| Description | The LCMS-9050 quadrupole time-of-flight mass spectrometer inherits the world-class mass accuracy and stability of the LCMS-9030 while incorporating newly developed UFstabilization technology for simultaneous positive ion/negative ion analysis with high mass accuracy at even higher speeds. Ease of The LCMS-9050 quadrupole time-of-flight mass spectrometer inherits the world-class mass accuracy and stability of the LCMS-9030 while incorporating newly developed UFstabilization technology for simultaneous positive ion/negative ion analysis with high mass accuracy at even higher speeds. Ease of use is evident throughout the system from mass calibration to maintenance, allowing the LCMS-9050 to be used easily in any scenario that requires accurate mass spectrometry.
Key features/benefits: - Stable long-term mass accuracy with a high-precision temperature control system that inhibits even tiny mass variations caused by external factors
- Achieves consistent mass accuracy values, even when samples are analyzed successively in both positive and negative ion modes; this significantly reduces the time required for stabilization and analysis for improved analytical throughput
- Fast, stable polarity switching through incorporation of proprietary high-precision electrical circuitry and the UFstabilization™ algorithm (patent pending)
- Ultrafast data acquisition rates
- Requires only a small sample size for identification of unknowns
- Auto-tuning function that uses a standard sample to automatically correct mass accuracy, resolution, sensitivity, and other parameters
- Easy maintenance; the desolvation line and the ESI capillary can be replaced quickly and easily without breaking vacuum, minimizing downtime
LabSolutions Insight Explore™ software manages and processes data on the LCMS-9050 system. It enables library searching, structural analysis, composition estimation, multivalent ion analysis, and quantitative analysis of target compounds. The software organizes and presents analysis results clearly in one easy-to-read screen.... Read More | The MegaTOF has been developed by optimizing the integration of a high-performance Shimadzu linear MALDI TOF mass spectrometer with a CovalX high-mass system, allowing outstanding detection of macromolecules up to 1,500 kDa.
Features - Ultrahigh sensitivity
- Detects macromolecules up to 1,500,000 Da
The MegaTOF has been developed by optimizing the integration of a high-performance Shimadzu linear MALDI TOF mass spectrometer with a CovalX high-mass system, allowing outstanding detection of macromolecules up to 1,500 kDa.
Features - Ultrahigh sensitivity
- Detects macromolecules up to 1,500,000 Da
- Stabilization of molecule using crosslinking reagent kits
- Fast, specific stabilization of protein interactions
- Also applicable for low mass applications
- Apple iPod Touch control
Applications - Antibody characterization
- Protein complexes characterization
- Therapeutic protein aggregates
- High mass MALDI imaging
- Inhibitors of protein-protein interactions
This product is only available in the United States.... Read More |
| Quantity | EA | EA |
| Get Quote | | |
Articles
- Expensive to Maintain, but Performs Great
- LECO and CDS Analytical Announce Relationship to Deliver Pyrolysis and High Performance GC-TOFMS
- Analysis of Wastewater Effluent Samples to Identify Toxic Chemicals Using the High-Resolution Agilent 7250 GC/Q-TOF
- Massbox® Mass Spectrometer
- Waters Combines Best-in-Class Performance, Versatility and Usability Technologies in New Xevo G2 Tof Benchtop System
- Waters Combines Best-in-Class Performance, Versatility and Usability Technologies in New Xevo G2 Tof Benchtop System
- Visit LECO at ASMS—Booth #125
- LECO Pittcon 2011 Posters Now Available
- ALMSCO International Highlights Its BenchTOF-dx for Improved Sensitivity at ASMS 2011
- PerkinElmer Launches AxION™ Mass Spectrometry Platform
- LECO Corporation to Host Free Webinar on Environmental Forensic Investigation
- LECO and ACD/Labs Collaborate for Software Support on New High Resolution TOFMS Systems
- Leco Corporation to Host Free Webinar On Identifying Ergogenic Aids and Metabolites in Urine
- LECO, Florida State University Partnership Benefits Future Fuels Research
- LECO and ACD/Labs Collaborate for Software Support on New High Resolution TOFMS Systems
- ThoMSon Mass Spectrometry Laboratory at Brazil’s University of Campinas Selected as Waters Center of Innovation
- IONICON celebrates 200 sold PTR-MS instruments
- Markes and ALMSCO International to jointly showcase high-sensitivity technology for trace-level aroma and fragrance profiling at Analytica 2012
- PerkinElmer Presents Latest Analytical Innovations at Analytica 2012
- AB SCIEX Announces Biologics Initiative
- Technical Presentations from Recent Shows Available from LECO
- LECO and Genedata Collaborate on Mass Spectrometry Data Analysis for High Resolution TOFMS Systems
- Online Training Now Available for LECO Separation Science Instrumentation
- LECO Corporation to Host Webinar on Dioxin Analysis
- Maintaining High Mass Resolution for Tissue Imaging with the JEOL SpiralTOF™
- New GC/TOF-Related Website Offers Analytical Chemists a Wealth of Information
- Business as Usual for Markes International as Schauenburg International Acquires a Majority Share
- LECO to Host Webinar on High Resolution GC-MS for Metabolomics Applications
- Chemical Ionization (HR-CI) Source Introduced by LECO for Pegasus® GC-HRT
- Pivot Park and Spinnovation Analytical join forces to provide analytical solutions at Pivot Park Life Sciences Community, Oss
- Agilent Technologies to Host Webinars on Food Safety and Quality
- Enhanced Analysis and Imaging Capabilities on Display at JEOL Pittcon Booth #2224
- AB SCIEX and LECO Partner to Offer Combined Solutions for GC/MS and LC/MS to Metabolomics Researchers
- New Chemical Ionization Application Notes from LECO
- LECO Announces Special Events at ASMS
- JEOL and Zoex Partnership Combines Comprehensive Two-Dimensional Gas Chromatography with High Sensitivity Mass Spectrometer
- Pegasus® HT GC-TOFMS
- Pegasus® 4D GCxGC-TOFMS: Comprehensive Two-Dimensional Gas Chromatography
- Chemical Ionization Source for Pegasus® GC-HRT
- Pegasus® GC-HRT (High Resolution TOFMS)
- Shimadzu's New MALDI-7090 TOF-TOF Mass Spectrometer Combines High Throughput, High Resolution and High Energy for the Ultimate in Tandem MS Capabilities
- AB SCIEX, Genedata & LECO Announce Partnership for New Cross-Platform Metabolomics Data Analysis Solution
- IONICON: The Leading PTR-MS Company Celebrates its 15th Anniversary
- LECO GCxGC Technology Used in Award-Winning Paper
- LECO to Host Webinar on GC-TOFMS Flavor Analysis
- Agalimmune Ltd Founded to Develop Immunotherapeutics for Cancer
- Forensic Mass Spectrometry
- Food Mass Spectrometry
- Cannabis Mass Spectrometry
- Analyzing Unknowns
- Next-Generation Software for Food and Forensic Laboratories
- Integrating GC/TOF Exposome Profiling and Genetic Disease Screening to Provide a Holistic Perspective on Honey Bee Health
- UCMR4, Microcystins Analysis, and High-Resolution Mass Spectrometry for Confidence in Identity Confirmation
- MALDI-TOF/TOF System Exceeds Your Expectations
- High quality and very accurate
- Buyers’ Guide: Best Buys for Mass Spectroscopy
- IONICON Launches the New Super-fast PTR-TOF 1000 Trace Gas Analyzer
- Pittcon Announces Highlights of Waters Symposium
- Researchers Discover That “Green” Household Cleaners Emit Just as Many Harmful Chemicals
- ‘Omics Research Dominates ASMS 2023
- ‘Hidden’ Pesticide Byproducts Found in Wild Birds of Prey
- Comprehensive Profiling of Environmental Contaminants in Surface Water Using High-Resolution GC/Q-TOF
- Contaminants Screening Using High-Resolution GC/Q-TOF and an Expanded Accurate Mass Library of Pesticides and Environmental Pollutants
- Short Chain Chlorinated Paraffins (SCCP) Analysis Using Negative Chemical Ionization (CI) and Low Energy EI by High-Resolution 7250 GC/Q-TOF
- Agilent to Present Food Science Data at AOAC: Pesticide Analysis, Gluten, Food Allergens, Whiskey
- Cerno Bioscience Announces Most Significant Upgrade of MassWorks™ Software Product
- Bruker Announces FDA Clearance to Market the MALDI Biotyper CA System
- More Data, Fewer Instruments: Simplifying the Battery Research Workflow
- Pre-screening Novel Psychoactive Substances to Speed Detection
- Pittcon Announces 2014 Editors' Awards: Journalists Select Gold, Silver and Bronze
- The Challenge of Tumor Heterogeneity in Personalized Medicine
- Child COVID-19 Breath Test Study IDs Potential Biomarkers
- Personal Products Comparable to Fossil Fuels in Urban Air Pollution
- Determination of Pain-Management Drugs in Human Urine Using “Flip-Flop” Chromatography and Time-of-Flight Mass Spectrometry
- Perspectives from ASMS 69: Part I