Quadrupole Mass Spectrometer (MS) / Quadrupole Mass Analyzer

Quadrupole Mass Spectrometer (MS) / Quadrupole Mass Analyzer Quadrupole mass spectrometers are perhaps the simplest of mass spec instruments. Functioning effectively like a radio, the quadrupole MS – so-named because of its four charged rods, which run parallel to the flight paths of the ions it measures – filter ions by mass-to-charge ratio (m/z) by altering the voltages in the rods. Quadrupole mass spectrometers are available in a variety of formats, including a single quadrupole mass spectrometer, a triple quadrupole MS (three quadrupoles arranged in tandem), and a Q-TOF (a triple quad variant in which the third quadrupole is replaced with a time-of-flight mass analyzer).

Quadrupole mass analyzers are often used for targeted, quantitative applications and can be used either to measure one or a few given ions in a mixture, or to scan across a range of m/z values. Depending on the configuration, they can facilitate both MS and MS/MS applications. For instance, in a triple-quadrupole mass spectrometer, you can select ions for analysis in the first quadrupole, fragment them by collision with a gas in the second quadrupole, and analyze the resulting fragmentation ions in the third quadrupole.

Find, compare, and request a quote for quadrupole mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Showing 9 of 9 products
  • <<
  • >>
Select up to 5 products from below to compare or request more information.
ISQ™ EC Single Quadrupole Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    API, HESI
  • Mass Analyzer:
    Single quadrupole
  • Scanning Speed:
    Up to 20,000 Da/sec.
  • Mass Range:
    10 to 1250 m/z
Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    HESI
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Inquire
  • Mass Range:
    m/z 50–2,000
    m/z 200–4,000
    up to m/z 6,000 without precursor ion selection (OTMS only)
Citations:
(35)
Q Exactive™ UHMR Hybrid Quadrupole-Orbitrap™ Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    UHMR Hybrid Quadrupole-Orbitrap™
  • Scanning Speed:
    up to 12 Hz at resolution setting of 12,500 at m/z 400
  • Mass Range:
    350 to 80,000 m/z
Citations:
(17)
Thermo Scientific™ ISQ™ 7610 Single Quadrupole GC-MS System
Thermo Fisher Scientific
  • Ionization Method(s):
    EI, FS, SIM, FS/SIM, CI, PCI, NCI, depending on model
  • Mass Analyzer:
    Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 µA
  • Scanning Speed:
    Inquire
  • Mass Range:
    1.2–1100 u with Unit Mass Resolution
Thermo Scientific™ ISQ™ EM Single Quadrupole Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Atmospheric pressure ionization (API) source with interchangeable HESI and APCI probes
  • Mass Analyzer:
    Single quadrupole
  • Scanning Speed:
    Up to 20,000 Da/sec.
  • Mass Range:
    10 to 2000 m/z with Unit Mass Resolution
Thermo Scientific™ TSQ™ 9610 Triple Quadrupole GC-MS/MS System
Thermo Fisher Scientific
  • Ionization Method(s):
    Varies by model, AEI, EI, CI
  • Mass Analyzer:
    Triple quadrupole
  • Scanning Speed:
    Inquire
  • Mass Range:
    Inquire
TSQ Altis™ MD Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Triple quadrupole
  • Scanning Speed:
    Inquire
  • Mass Range:
    5 to 3000 m/z
TSQ Quantis™ MD Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Triple quadrupole
  • Scanning Speed:
    Inquire
  • Mass Range:
    5 to 3000 m/z
Orbitrap™ Astral™ Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Adjustable heated electrospray ionization (HESI) probe
  • Mass Analyzer:
    Orbitrap mass analyzer ranging from 7,500 to 480,000 resolution at m/z 200
    Astral mass analyzer is operated at a single resolution setting of 80,000 at m/z 524
  • Scanning Speed:
    Up to 200 Hz
  • Mass Range:
    Maximum Astral mass analyzer resolution up to 80,000 FWHM at m/z 524
    Maximum Orbitrap mass analyzer resolution of up to 480,000 FWHM at m/z 200
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • JEOL USA, Inc.
  • Microtrac Inc.
  • NETZSCH-Gerätebau GmbH
  • PerkinElmer
  • SCIEX
  • Shimadzu
  • TA Instruments – a division of Waters Corporation
  • Thermo Fisher Scientific

Review Laboratory Products

Review the laboratory equipment you use and receive an Amazon gift card!

Submit a Review
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!

Note: Labcompare disclaims any information on this site.