Quadrupole Mass Spectrometer (MS) / Quadrupole Mass Analyzer

Quadrupole mass spectrometers are perhaps the simplest of mass spec instruments. Functioning effectively like a radio, the quadrupole MS – so-named because of its four charged rods, which run parallel to the flight paths of the ions it measures – filter ions by mass-to-charge ratio (m/z) by altering the voltages in the rods. Quadrupole mass spectrometers are available in a variety of formats, including a single quadrupole mass spectrometer, a triple quadrupole MS (three quadrupoles arranged in tandem), and a Q-TOF (a triple quad variant in which the third quadrupole is replaced with a time-of-flight mass analyzer).

Quadrupole mass analyzers are often used for targeted, quantitative applications and can be used either to measure one or a few given ions in a mixture, or to scan across a range of m/z values. Depending on the configuration, they can facilitate both MS and MS/MS applications. For instance, in a triple-quadrupole mass spectrometer, you can select ions for analysis in the first quadrupole, fragment them by collision with a gas in the second quadrupole, and analyze the resulting fragmentation ions in the third quadrupole.

Find, compare, and request a quote for quadrupole mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher Scientific
ItemQ Exactive™ UHMR Hybrid Quadrupole-Orbitrap™ Mass SpectrometerOrbitrap™ Astral™ Mass SpectrometerThermo Scientific™ ISQ™ 7610 Single Quadrupole GC-MS SystemThermo Scientific™ TSQ™ 9610 Triple Quadrupole GC-MS/MS SystemTSQ Altis™ MD Mass Spectrometer
Citations
Catalog NumberIQLAAEGAAPFALGMAZRIQLAAEGAAPFARYMBOBIQLAAAGAAJFALOMBNAIQLAAAGABNFARPMBNBIQLAAEGAAXFAQSMBLC
Price
Ionization Method(s)InquireAdjustable heated electrospray ionization (HESI) probeEI, FS, SIM, FS/SIM, CI, PCI, NCI, depending on modelVaries by model, AEI, EI, CIInquire
Mass AnalyzerUHMR Hybrid Quadrupole-Orbitrap™Orbitrap mass analyzer ranging from 7,500 to 480,000 resolution at m/z 200
Astral mass analyzer is operated at a single resolution setting of 80,000 at m/z 524
Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 µATriple quadrupoleTriple quadrupole
Scanning Speedup to 12 Hz at resolution setting of 12,500 at m/z 400Up to 200 HzInquireInquireInquire
Mass Range350 to 80,000 m/zMaximum Astral mass analyzer resolution up to 80,000 FWHM at m/z 524
Maximum Orbitrap mass analyzer resolution of up to 480,000 FWHM at m/z 200
1.2–1100 u with Unit Mass ResolutionInquire5 to 3000 m/z
DescriptionThe Thermo Scientific™ Q Exactive™ UHMR Hybrid Quadrupole-Orbitrap™ mass spectrometer is the first to provide the unique combination of unprecedented ultra-high mass range resolution, highest sensitivity, and MS2 and pseudo-MS3 capabilities needed to go beyond what’s possible with today’s native MS ... Read MoreInquireDeveloped to enhance user experience in their workflows, the ISQ 7610 GC-MS system is streamlined to ensure great data consistency over time while offering automated instrument control tools.The TSQ 9610 GC-MS/MS system is designed to revolutionize laboratory productivity by delivering unprecedented levels of performance and reduce cost per sample for the high-throughput environment.Achieve the sensitivity to perform routine quantitative analyses with remarkable speed and robustness. The Thermo Scientific™ TSQ Quantis™ MD Series mass spectrometer can be used by clinical diagnostic laboratories to meet their routine requirements for laboratory developed tests (LDTs). With Active... Read More