| Description | The LCMS-8065XE introduces innovative technologies that deliver exceptional performance with evolved, efficient and exact capabilities.
The instrument incorporates Shimadzu’s complete Ultra Fast Mass Spectrometry (UFMS) technology suite:
- World-class 5 msec positive/negative ion switching with
The LCMS-8065XE introduces innovative technologies that deliver exceptional performance with evolved, efficient and exact capabilities.
The instrument incorporates Shimadzu’s complete Ultra Fast Mass Spectrometry (UFMS) technology suite:
- World-class 5 msec positive/negative ion switching with zero signal loss
- Ultra-fast MRM acquisition up to 555 channels/sec
- Scanning up to 30,000 u/sec with maximum ion transmittance
- Advanced UF-Qarray™II & UF-Lens™ II ion guides for maximum transmission efficiency
New advancements include:
- StreamFocus Ionization Technology – The LCMS-8065XE features a low-dispersion nebulizer nozzle that dramatically reduces liquid droplet dispersion while maximizing ion intake efficiency. This breakthrough reduces nebulizer gas consumption by up to 7-fold compared to conventional ESI sources and achieves exceptional sensitivity improvements, particularly in negative mode.
- Enhanced IonFocus Performance – The evolved IonFocus unit utilizes a focusing electrode to selectively guide ions into the intake port while excluding neutral matrix components. This ensures sensitivity even when the ion spray is positioned further from the intake port, delivering superior robustness for long-term analysis.
- UFsweeper™ IV Collision Cell – The next-generation collision cell features a larger inlet lens diameter and an increased number of lenses for improved ion throughput, enhanced ion transmission, and dramatically improved sensitivity and quantitative precision.
- Performance Concierge – Automatically monitors system performance, provides proactive maintenance alerts, and reduces instrument downtime through predictive diagnostics. Peakintelligence for LCMS delivers revolutionary AI-driven peak detection with up to 67% reduction in manual review time and superior reproducibility across complex analyses.
The LCMS-8065XE excels across environmental monitoring, food safety, pharmaceutical analysis, clinical research, and industrial quality control applications.
It particularly excels for analysis of PFAS.
The LCMS-8065XE demonstrates remarkable capabilities with sub-ng/L detection limits for PFAS compounds in drinking water using direct injection.
The system delivers 3–48 fold sensitivity enhancement compared to previous generation instruments while maintaining exceptional stability – over 85% of initial response retained after more than 10,000 consecutive injections of complex wastewater samples (RSD <7%)
LabSolutions LCMS workstation software offers total operator support, from analysis to data processing.
The LabSolutions Connect/LabSolutions Insight platform supports the entire analysis workflow:
- Project file management
- Optimization of MRM and interface parameters
- Efficient verification of quantitative results
- Simple method and batch creation
- Verification of quantitative results
... Read More | Utilizing patented ultrafast (UF) technology, the LCMS-2020 mass spectrometer offers fast measurements and outstanding detection sensitivity for quicker and more accurate detection of trace impurities in a variety of applications.
Features - Ultrafast scanning speed of 15,000 u/sec, without
Utilizing patented ultrafast (UF) technology, the LCMS-2020 mass spectrometer offers fast measurements and outstanding detection sensitivity for quicker and more accurate detection of trace impurities in a variety of applications.
Features - Ultrafast scanning speed of 15,000 u/sec, without sacrificing sensitivity or resolution
- Unsurpassed 15 msec polarity switching speed, for the most data without peak deterioration in a single injection
- Multiple Ionization options – ESI, APCI, and DUIS
- Dual Ion Source – truly enables simultaneous ESI and APCI analysis
- Easy system maintenance – enables greater uptime and usability
- Innovative ion optics—provide greater sensitivity than any other single quadrupole analyzer
- Backwards compatible – no need to upgrade your HPLC
The ESI method typically used for LCMS can be replaced with APCI, which is suitable for neutral compounds, or with a dual ionization source (DUIS) for simultaneous operation of both ionization modes, quickly and without tools. Selection of the DUIS ionization mode (ESI or APCI) can be performed via the computer. In addition, the desolvation line, where the ions enter the MS unit, can be replaced without breaking vacuum.... Read More | Incorporating Shimadzu’s proprietary ultrafast technologies (UF Technologies), the triple quadrupole LCMS-8050RX offers outstanding measurement speeds and quantitative performance.
Specific and highly sensitive Multiple Reaction Monitoring (MRM) multi-component analysis is improved with a heated Incorporating Shimadzu’s proprietary ultrafast technologies (UF Technologies), the triple quadrupole LCMS-8050RX offers outstanding measurement speeds and quantitative performance.
Specific and highly sensitive Multiple Reaction Monitoring (MRM) multi-component analysis is improved with a heated electrospray source and ultra-efficient collision cell.
Combine with Shimadzu’s world-leading UHPLC systems for an unmatched level of performance.
Features:
- Ultrafast polarity switching (5 msec) – maintains constant quality and sensitivity with no loss of quantitative accuracy
- Ultra-high-speed scan rate of 30,000 u/sec – obtains high-quality mass spectra, even during high-speed analysis
- Ultrafast MRM transition speeds, up to 555 MRMs per second
- Heated ESI probe – promotes the ionization of wide range of targeted compounds
- CoreSpray™ gas delivery system – enhances reliability by increasing gas flow and improving nebulizer coaxiality
- High-efficiency CID cell – maintains signal intensity and suppresses crosstalk, even for high-speed or simultaneous multicomponent analysis
- Performance Concierge – Automatically monitors system performance, provides proactive maintenance alerts, and reduces instrument downtime through predictive diagnostics
- Easy maintenance – Changing the ESI capillary and the desolvation line (DL) can be quickly replaced without breaking vacuum
Intuitive LabSolutions software allows for simplified instrument control, diverse data handling, and integration with regulatory compliance requirements.
Optional LabSolutions Insight data review software, supporting review-by-exception, dramatically improves the speed and efficiency of multi-analyte data analysis.
In addition, LabSolutions MRM Connect automates MRM optimization to create high sensitivity quantitative LC-MS/MS methods. ... Read More | The LCMS-9050 quadrupole time-of-flight mass spectrometer inherits the world-class mass accuracy and stability of the LCMS-9030 while incorporating newly developed UFstabilization technology for simultaneous positive ion/negative ion analysis with high mass accuracy at even higher speeds. Ease of The LCMS-9050 quadrupole time-of-flight mass spectrometer inherits the world-class mass accuracy and stability of the LCMS-9030 while incorporating newly developed UFstabilization technology for simultaneous positive ion/negative ion analysis with high mass accuracy at even higher speeds. Ease of use is evident throughout the system from mass calibration to maintenance, allowing the LCMS-9050 to be used easily in any scenario that requires accurate mass spectrometry.
Key features/benefits: - Stable long-term mass accuracy with a high-precision temperature control system that inhibits even tiny mass variations caused by external factors
- Achieves consistent mass accuracy values, even when samples are analyzed successively in both positive and negative ion modes; this significantly reduces the time required for stabilization and analysis for improved analytical throughput
- Fast, stable polarity switching through incorporation of proprietary high-precision electrical circuitry and the UFstabilization™ algorithm (patent pending)
- Ultrafast data acquisition rates
- Requires only a small sample size for identification of unknowns
- Auto-tuning function that uses a standard sample to automatically correct mass accuracy, resolution, sensitivity, and other parameters
- Easy maintenance; the desolvation line and the ESI capillary can be replaced quickly and easily without breaking vacuum, minimizing downtime
LabSolutions Insight Explore™ software manages and processes data on the LCMS-9050 system. It enables library searching, structural analysis, composition estimation, multivalent ion analysis, and quantitative analysis of target compounds. The software organizes and presents analysis results clearly in one easy-to-read screen.... Read More |