| Description | The LCMS-8065XE introduces innovative technologies that deliver exceptional performance with evolved, efficient and exact capabilities.
The instrument incorporates Shimadzu’s complete Ultra Fast Mass Spectrometry (UFMS) technology suite:
- World-class 5 msec positive/negative ion switching with
The LCMS-8065XE introduces innovative technologies that deliver exceptional performance with evolved, efficient and exact capabilities.
The instrument incorporates Shimadzu’s complete Ultra Fast Mass Spectrometry (UFMS) technology suite:
- World-class 5 msec positive/negative ion switching with zero signal loss
- Ultra-fast MRM acquisition up to 555 channels/sec
- Scanning up to 30,000 u/sec with maximum ion transmittance
- Advanced UF-Qarray™II & UF-Lens™ II ion guides for maximum transmission efficiency
New advancements include:
- StreamFocus Ionization Technology – The LCMS-8065XE features a low-dispersion nebulizer nozzle that dramatically reduces liquid droplet dispersion while maximizing ion intake efficiency. This breakthrough reduces nebulizer gas consumption by up to 7-fold compared to conventional ESI sources and achieves exceptional sensitivity improvements, particularly in negative mode.
- Enhanced IonFocus Performance – The evolved IonFocus unit utilizes a focusing electrode to selectively guide ions into the intake port while excluding neutral matrix components. This ensures sensitivity even when the ion spray is positioned further from the intake port, delivering superior robustness for long-term analysis.
- UFsweeper™ IV Collision Cell – The next-generation collision cell features a larger inlet lens diameter and an increased number of lenses for improved ion throughput, enhanced ion transmission, and dramatically improved sensitivity and quantitative precision.
- Performance Concierge – Automatically monitors system performance, provides proactive maintenance alerts, and reduces instrument downtime through predictive diagnostics. Peakintelligence for LCMS delivers revolutionary AI-driven peak detection with up to 67% reduction in manual review time and superior reproducibility across complex analyses.
The LCMS-8065XE excels across environmental monitoring, food safety, pharmaceutical analysis, clinical research, and industrial quality control applications.
It particularly excels for analysis of PFAS.
The LCMS-8065XE demonstrates remarkable capabilities with sub-ng/L detection limits for PFAS compounds in drinking water using direct injection.
The system delivers 3–48 fold sensitivity enhancement compared to previous generation instruments while maintaining exceptional stability – over 85% of initial response retained after more than 10,000 consecutive injections of complex wastewater samples (RSD <7%)
LabSolutions LCMS workstation software offers total operator support, from analysis to data processing.
The LabSolutions Connect/LabSolutions Insight platform supports the entire analysis workflow:
- Project file management
- Optimization of MRM and interface parameters
- Efficient verification of quantitative results
- Simple method and batch creation
- Verification of quantitative results
... Read More | Adopting a proprietary multi-function ion source and a new large-capacity turbomolecular pump with heightened exhaust efficiency for all carrier gases including nitrogen, the rugged, high-sensitivity GCMS-QP2020 NX elevates GCMS performance to a new level. New Quick-CI and Smart SIM functionality Adopting a proprietary multi-function ion source and a new large-capacity turbomolecular pump with heightened exhaust efficiency for all carrier gases including nitrogen, the rugged, high-sensitivity GCMS-QP2020 NX elevates GCMS performance to a new level. New Quick-CI and Smart SIM functionality reduces analysis times and running costs while front access to the ion source enables easier routine maintenance.
Features: - Smart SIM creation function – automatically creates a program that enables a staggered SIM of multiple components, resulting in higher SIM sensitivity
- Quick-CI function – allows users to introduce reagent gas while using the EI source to look for the molecular ion
- Advanced Scanning Speed Protocol – allows for the ability to scan up to 20,000 u/sec
- New turbomolecular pump achieves optimal performance with all carrier gases
- Front access to the ion source for easier, faster routine maintenance
- Simultaneous Scan/SIM for qualitative and quantitative data in a single run
- Twin-Line MS System – allows the GCMS-QP2020 NX to accept two narrow-bore capillary columns into the MS simultaneously, enabling users to switch applications without physically modifying the column installation
- Specialized databases with additional retention indices support more accurate qualitative analysis, convenient quantitative method development, and screening analysis.
Other features of the GCMS-QP2020 NX include a high-capacity differential vacuum system; high-sensitivity ion source; high-performance quadrupole mass filter; and easy sTop, which enables users to perform maintenance on the injection port without venting the MS, for drastic reduction of maintenance time. GCMSsolution software provides intuitive control of the GCMS-QP2020 NX. Also available is LabSolutions Insight. This data review software enables faster quantitative analysis and higher productivity when analyzing pesticides, forensic toxicological substances, environmental pollutants, and many other substances. In addition, each system can be configured with a variety of sample introduction devices to address specific application requirements.... Read More | Incorporating Shimadzu’s proprietary ultrafast technologies (UF Technologies), the triple quadrupole LCMS-8050RX offers outstanding measurement speeds and quantitative performance.
Specific and highly sensitive Multiple Reaction Monitoring (MRM) multi-component analysis is improved with a heated Incorporating Shimadzu’s proprietary ultrafast technologies (UF Technologies), the triple quadrupole LCMS-8050RX offers outstanding measurement speeds and quantitative performance.
Specific and highly sensitive Multiple Reaction Monitoring (MRM) multi-component analysis is improved with a heated electrospray source and ultra-efficient collision cell.
Combine with Shimadzu’s world-leading UHPLC systems for an unmatched level of performance.
Features:
- Ultrafast polarity switching (5 msec) – maintains constant quality and sensitivity with no loss of quantitative accuracy
- Ultra-high-speed scan rate of 30,000 u/sec – obtains high-quality mass spectra, even during high-speed analysis
- Ultrafast MRM transition speeds, up to 555 MRMs per second
- Heated ESI probe – promotes the ionization of wide range of targeted compounds
- CoreSpray™ gas delivery system – enhances reliability by increasing gas flow and improving nebulizer coaxiality
- High-efficiency CID cell – maintains signal intensity and suppresses crosstalk, even for high-speed or simultaneous multicomponent analysis
- Performance Concierge – Automatically monitors system performance, provides proactive maintenance alerts, and reduces instrument downtime through predictive diagnostics
- Easy maintenance – Changing the ESI capillary and the desolvation line (DL) can be quickly replaced without breaking vacuum
Intuitive LabSolutions software allows for simplified instrument control, diverse data handling, and integration with regulatory compliance requirements.
Optional LabSolutions Insight data review software, supporting review-by-exception, dramatically improves the speed and efficiency of multi-analyte data analysis.
In addition, LabSolutions MRM Connect automates MRM optimization to create high sensitivity quantitative LC-MS/MS methods. ... Read More | The triple quad LCMS-8060RX utilizes proprietary technologies and more efficient ion transfer to achieve outstanding speed and sensitivity.
A heat-assisted electrospray ionization probe delivers a highly efficient desolvation process that promotes the ionization of a wide range of target compounds The triple quad LCMS-8060RX utilizes proprietary technologies and more efficient ion transfer to achieve outstanding speed and sensitivity.
A heat-assisted electrospray ionization probe delivers a highly efficient desolvation process that promotes the ionization of a wide range of target compounds while the systems unique IonFocus™ electrode efficiently delivers ions into the mass spectrometer, resulting in lower noise levels, superior data quality and reduced maintenance needs.
Additional features include:
- CoreSpray™ gas delivery system – enhances reliability by increasing gas flow and improving nebulizer coaxiality.
- Ultrafast high-voltage power supply – enables sensitive and stable signal detection
- UFsweeper Collision Cell – delivers fast and accurate MRM quantitation; high-speed and high-efficiency CID occurs as ions are accelerated through the cell, enabling multi-component analysis with little signal degradation or crosstalk
- Scan speed of 30,000 u/s
- 5 ms polarity switching time
- Ultra-fast MRM measurements up to 555 ch/sec
- IonFocus™ electrode – effectively removes matrix contaminants, resulting in lower noise levels, superior data quality and reduced maintenance needs
- Easy maintenance – Consumable parts like the ESI spray needle and the inlet desolvation line (DL) can be changed quickly and easily without breaking vacuum.
- Performance Concierge – Automatically monitors system performance, provides proactive maintenance alerts, and reduces instrument downtime through predictive diagnostics.
LabSolutions LCMS workstation software offers total operator support, from analysis to data processing.
The LabSolutions Connect/LabSolutions Insight platform supports the entire analysis workflow, including:
- Project file management
- Optimization of MRM and interface parameters
- Efficient verification of quantitative results
- Simple method and batch creation
- Verification of quantitative results
... Read More | The LCMS-9050 quadrupole time-of-flight mass spectrometer inherits the world-class mass accuracy and stability of the LCMS-9030 while incorporating newly developed UFstabilization technology for simultaneous positive ion/negative ion analysis with high mass accuracy at even higher speeds. Ease of The LCMS-9050 quadrupole time-of-flight mass spectrometer inherits the world-class mass accuracy and stability of the LCMS-9030 while incorporating newly developed UFstabilization technology for simultaneous positive ion/negative ion analysis with high mass accuracy at even higher speeds. Ease of use is evident throughout the system from mass calibration to maintenance, allowing the LCMS-9050 to be used easily in any scenario that requires accurate mass spectrometry.
Key features/benefits: - Stable long-term mass accuracy with a high-precision temperature control system that inhibits even tiny mass variations caused by external factors
- Achieves consistent mass accuracy values, even when samples are analyzed successively in both positive and negative ion modes; this significantly reduces the time required for stabilization and analysis for improved analytical throughput
- Fast, stable polarity switching through incorporation of proprietary high-precision electrical circuitry and the UFstabilization™ algorithm (patent pending)
- Ultrafast data acquisition rates
- Requires only a small sample size for identification of unknowns
- Auto-tuning function that uses a standard sample to automatically correct mass accuracy, resolution, sensitivity, and other parameters
- Easy maintenance; the desolvation line and the ESI capillary can be replaced quickly and easily without breaking vacuum, minimizing downtime
LabSolutions Insight Explore™ software manages and processes data on the LCMS-9050 system. It enables library searching, structural analysis, composition estimation, multivalent ion analysis, and quantitative analysis of target compounds. The software organizes and presents analysis results clearly in one easy-to-read screen.... Read More |