MALDI TOF mass spectrometers (matrix-assisted laser desorption/ionization/time-of-flight) are amongst the most popular mass spec instruments in biology. They combine two technologies, the “soft” MALDI ionization source and the TOF mass analyzer. The latter measures an ion’s mass-to-charge ratio (m/z) by measuring the time it takes to reach a detector. The former volatilizes and ionizes those molecules using a laser, a target, and an organic compound called a matrix. In MALDI, a sample (for instance, a collection of tryptic peptides) is mixed with matrix, spotted and dried (crystallized) on the surface of a metal target plate. Upon irradiation with laser light, the matrix absorbs the energy and converts it to heat, which then causes the sample to ionize and explode off the plate into the mass analyzer. MALDI TOF mass spectrometers come in two basic flavors, MALDI TOF MS and MALDI TOF/TOF MS; the latter enables tandem MS (MS/MS) studies.
CompanyShimadzuShimadzuShimadzuShimadzuShimadzu
ItemAxima Performance MALDI TOF TOF Mass SpectrometerAXIMA-iD Plus Microorganism AnalysisiMScope QT Imaging Mass MicroscopeMALDImini-1 Compact MALDI Digital Ion Trap Mass SpectrometerOmegaTOF Benchtop High Mass MALDI-TOF Mass Spectrometer
Citations
(1)
Figures
(3)
Catalog NumberAxima PerformanceAXIMA-iD PlusiMScope QTMALDImini-1OmegaTOF
Price
Ionization Method(s)MALDIMALDIAtmospheric Pressure MALDI (AP-MALDI)MALDI ion sourceMALDI
Mass AnalyzerTOF/TOFMALDI-TOF MSQ-TOFDigital Ion Trap (DIT)Time-of-Flight
Resolution>20,000 FWHM (Reflectron mode)InquireInquireInquire>5000 FWHM – ACTH 18-39 (m/z 2465)
Scanning SpeedInquireInquireInquireInquireInquire
Mass Range1 kDa to 500 kDaVaries based on MALDI-TOF system usedInquireInquirem/z 1,000–1,500,000Da
Description

The AXIMA Performance is one of the most powerful tools in mass spectrometry, delivering information-rich spectra with greater sensitivity and higher confidence in identification. Extremely versatile, this MALDI TOF-TOF mass spectrometer utilizes state-of-the-art high energy MS/MS, delivers

... Read More
Certain microorganisms can cause severe diseases and considerable damage, and need to be identified quickly and reliably. The easy-to-use AXIMA-iDPlus Microbial Identification System is the ideal tool to address these concerns. With AXIMA-iDPlus, cultured microorganisms can be directly applied to ... Read MoreInquireInquireThe OmegaTOF system couples Shimadzu’s benchtop MALDI-TOF instrument platform (MALDI-8020) with established technology for high mass detection from CovalX Instruments Inc. The result is a user-friendly, compact platform that extends benchtop MALDI-TOF analysis to a mass range of 1.5 MegaDalton.

The
... Read More
Get Quote