LC MS Instrument

LC MS Instrument Comprising two components, a liquid-phase separation system and a mass spectrometer, liquid chromatograph mass spectrometers (LC MS instruments) couple sample fractionation and analysis. The separation can be accomplished via standard liquid chromatography, HPLC, UPLC, or even nano-LC. Any liquid-phase separation will do, so long as its output can be directed into the mass analyzer (for instance, via an electrospray ionization source). The mass spectrometer is similarly flexible, ranging from the simplest single quadrupole to a Fourier transform ion cyclotron resonance instrument. Just remember, in a liquid chromatograph mass spectrometer the column flow is continuous, meaning the mass analyzer must be fast enough to thoroughly analyze one peak before the next one comes off the column. And, unlike with MALDI MS, once a peak is analyzed, it’s gone.

Showing 9 of 9 products
  • <<
  • >>
Select up to 5 products from below to compare or request more information.
Orbitrap Eclipse™ Tribrid™ Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    OTMSn up to 40 Hz ITMSn up to 45 Hz
  • Resolution:
    7500 to 500,000 (FWHM) at m/z 200
Orbitrap Exploris™ 240 Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI and HRAM
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Up to 22 Hz at resolution setting of 15,000 at m/z 200
  • Resolution:
    Up to 240,000 at m/z 200
Orbitrap Exploris™ 480 Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI and HRAM
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Up to 40 Hz at resolution setting of 7500 at m/z 200
  • Resolution:
    480,000 at m/z 195
Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    HESI
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Inquire
  • Resolution:
    7500-500,000 (FWHM) at m/z 200
Citations:
(35)
Orbitrap IQ-X™ Tribrid™ Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Inquire
  • Resolution:
    7500 to 500,000 (FWHM) at m/z 200
Q Exactive™ UHMR Hybrid Quadrupole-Orbitrap™ Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    UHMR Hybrid Quadrupole-Orbitrap™
  • Scanning Speed:
    up to 12 Hz at resolution setting of 12,500 at m/z 400
  • Resolution:
    200,000 at m/z 400
Citations:
(17)
Thermo Scientific™ Tox Explorer™ Collection for Orbitrap™ Exploris™ 120 MS
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Up to 22 Hz
  • Resolution:
    Up to 120,000 (FWHM) at m/z 200, demonstrates outstanding resolving power, according to a product page
Tox Explorer™ Collection for Quantis™ Plus MS
Thermo Fisher Scientific
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
Orbitrap Exploris™ 120 Mass Spectrometer
Thermo Fisher Scientific
  • Ionization Method(s):
    ESI and HRAM
  • Mass Analyzer:
    Orbitrap
  • Scanning Speed:
    Up to 22 Hz at resolution setting of 15,000 at m/z 200
  • Resolution:
    Up to 120,000 at m/z 200
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags

Articles

  • <<
  • >>
  • Gilson Inc
  • JEOL USA, Inc.
  • PerkinElmer
  • SCIEX
  • Shimadzu
  • Thermo Fisher Scientific
  • Waters | Wyatt Technology

Review Laboratory Products

Review the laboratory equipment you use and receive an Amazon gift card!

Submit a Review
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!