LC MS Instrument

Comprising two components, a liquid-phase separation system and a mass spectrometer, liquid chromatograph mass spectrometers (LC MS instruments) couple sample fractionation and analysis. The separation can be accomplished via standard liquid chromatography, HPLC, UPLC, or even nano-LC. Any liquid-phase separation will do, so long as its output can be directed into the mass analyzer (for instance, via an electrospray ionization source). The mass spectrometer is similarly flexible, ranging from the simplest single quadrupole to a Fourier transform ion cyclotron resonance instrument. Just remember, in a liquid chromatograph mass spectrometer the column flow is continuous, meaning the mass analyzer must be fast enough to thoroughly analyze one peak before the next one comes off the column. And, unlike with MALDI MS, once a peak is analyzed, it’s gone.

Showing 7 of 7 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
LCMS-2020 Single Quadrupole Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization
  • Mass Analyzer:
    Single Quadrupole
  • Scanning Speed:
    15,000 u/sec
  • Resolution:
    R = 2 M
Citations:
(918)
Figures:
(1)
LCMS-2050 Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization
  • Mass Analyzer:
    Single Quadrupole
  • Scanning Speed:
    15,000 u/sec
  • Resolution:
    Inquire
LCMS-8050 Triple Quadrupole LC/MS/MS Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    30,000 u/sec
  • Resolution:
    R < 0.7 u FWHM
Citations:
(597)
Figures:
(2)
LCMS-8060 NX Triple Quadrupole LC/MS/MS Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI probe with focus electrodes
  • Mass Analyzer:
    Triple quadrupole
  • Scanning Speed:
    Max. 30,000 u/sec (in all scan modes)
    (0.1 u step: 300,000 data points/sec)
  • Resolution:
    R < 0.7 u FWHM and adjustable to 0.5 u
Citations:
(15)
LCMS-8060 Triple Quadrupole LC/MS/MS Mass Spectrometer
Shimadzu
  • Ionization Method(s):
    ESI, APCI, Dual Ionization
  • Mass Analyzer:
    Q1 & Q3 are molybdenum hyperbolic mass filters with pre-rods; Q1 includes post-rods
  • Scanning Speed:
    30,000 u/sec
  • Resolution:
    R < 0.7 u FWHM
Citations:
(366)
Figures:
(1)
Nexera Mikros Microflow Liquid Chromatography Mass Spectrometer System
Shimadzu
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
Citations:
(9)
Nexera QX Multiplex LC-MS
Shimadzu
  • Ionization Method(s):
    Inquire
  • Mass Analyzer:
    Inquire
  • Scanning Speed:
    Inquire
  • Resolution:
    Inquire
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags

Articles

  • <<
  • >>
Shimadzu
LCMS-2020
4
1 Figure from 918 Publications
Shimadzu
LCMS-8050
2
2 Figures from 597 Publications
Shimadzu
LCMS-8060
2
1 Figure from 366 Publications
Showing 3 of 3 products
  • <<
  • >>
  • JASCO
  • PerkinElmer
  • SCIEX
  • Shimadzu
  • Thermo Fisher Scientific
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!