LC MS Instrument

Comprising two components, a liquid-phase separation system and a mass spectrometer, liquid chromatograph mass spectrometers (LC MS instruments) couple sample fractionation and analysis. The separation can be accomplished via standard liquid chromatography, HPLC, UPLC, or even nano-LC. Any liquid-phase separation will do, so long as its output can be directed into the mass analyzer (for instance, via an electrospray ionization source). The mass spectrometer is similarly flexible, ranging from the simplest single quadrupole to a Fourier transform ion cyclotron resonance instrument. Just remember, in a liquid chromatograph mass spectrometer the column flow is continuous, meaning the mass analyzer must be fast enough to thoroughly analyze one peak before the next one comes off the column. And, unlike with MALDI MS, once a peak is analyzed, it’s gone.
CompanyThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher ScientificThermo Fisher Scientific
ItemQ Exactive™ UHMR Hybrid Quadrupole-Orbitrap™ Mass SpectrometerOrbitrap Exploris™ 120 Mass SpectrometerOrbitrap Fusion™ Lumos™ Tribrid™ Mass SpectrometerOrbitrap IQ-X™ Tribrid™ Mass SpectrometerTox Explorer™ Collection for Quantis™ Plus MS
Citations
Reviews
Catalog NumberIQLAAEGAAPFALGMAZRIQLAAEGAAPFARBMBKQIQLAAEGAAPFADBMBHQIQLAAEGAAPFADBMBMAWFLOW-62003
Price
Ionization Method(s)InquireESI and HRAMHESIESIInquire
Mass AnalyzerUHMR Hybrid Quadrupole-Orbitrap™OrbitrapOrbitrapOrbitrapInquire
Scanning Speedup to 12 Hz at resolution setting of 12,500 at m/z 400Up to 22 Hz at resolution setting of 15,000 at m/z 200InquireInquireInquire
Resolution200,000 at m/z 400Up to 120,000 at m/z 2007500-500,000 (FWHM) at m/z 2007500 to 500,000 (FWHM) at m/z 200Inquire
DescriptionThe Thermo Scientific™ Q Exactive™ UHMR Hybrid Quadrupole-Orbitrap™ mass spectrometer is the first to provide the unique combination of unprecedented ultra-high mass range resolution, highest sensitivity, and MS2 and pseudo-MS3 capabilities needed to go beyond what’s possible with today’s native MS ... Read MoreThe Thermo Scientific Orbitrap Exploris 120 mass spectrometer accelerates your route to qualitative and quantitative confidence for both method development and everyday testing purposes. With its unique ability to provide consistently accurate data and a design made for operational simplicity, it ... Read MoreExcel at the most challenging of applications, including low level PTM analysis, multiplexed relative quantitation using isobaric tags, intact protein characterization, as well as MSn analysis of small molecules with the new Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer. This... Read MoreBuilt for small-molecule analyses, the Thermo Scientific™ Orbitrap IQ-X™ Tribrid™ mass spectrometer reveals your most complex chemical structures? with ultimate confidence, ease, and experimental versatility.An all-in-one LC-MS/MS workflow solution for toxicology. Increase productivity with SRM acquisition speeds enabling faster polarity switching of both positive and negative compounds. Triple quadrupole option includes experimentally obtained compound database and retention times of over 1100 ... Read More
QuantityEAEAEAEAEA
TypeQuadrupole-Orbitrap LC-MSOrbitrap LC-MSInquireOrbitrap Tribrid Mass SpectrometerTox Explorer Collection
Get Quote

Articles