Inductively coupled plasma mass spectrometers (ICP-MS) utilize inductively coupled plasma for sample ionization and an MS for ion separation and quantification. The low detection limits and high productivity possible with ICP-MS are particularly useful for trace metal analysis and environmental testing. Common components of an ICP-MS system include a sample introduction system, an ion source, a vacuum system, a collision reaction cell, ion optics, a mass spectrometer (often a quadrupole), and a detector. An analytical working range of nine orders of magnitude, detection limits below the ppt range, and aptitude for isotopic analysis are hallmarks of ICP-MS. ICP-MS instruments are commonly configured for routine analyses, high-matrix interference samples, or specific applications, such as work in the semiconductor industry or medical and forensic toxicology fields. Also, be sure to consider any desired customization options, such as chromatographic coupling or use with organic solvents.
Find, compare, and request a quote for inductively coupled plasma mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
Get Quote for All
Select up to 5 products from below to compare or request more information.
Thermo Fisher Scientific
- Single Quadrupole
- Inquire
- >9 orders of magnitude (<1 to >1 x 109 cps)
Thermo Fisher Scientific
- Double-focusing magnetic sector; three resolution settings: R = 300, 4,000, 10,000; magnet jump time <150 ms (7Li–²³8U–7Li)
- >3×106 cps/ppb (¹¹5In) wet plasma with Jet Interface; >3–5×107 cps/ppb (¹¹5In) dry plasma
- >9 orders of magnitude (>10? cps linear dynamic range)
Thermo Fisher Scientific
- Double-focusing magnetic sector; three resolution settings: R = 300, 4,000, 10,000; triple detection (SEM + Faraday + filter lens); auto-switch to Faraday above SEM range
- >3×106 cps/ppb (¹¹5In) wet plasma with Jet Interface; >3–5×107 cps/ppb (¹¹5In) dry plasma
- >12 orders of magnitude (>10¹² cps linear dynamic range)
Thermo Fisher Scientific
- Single quadrupole; QCell collision/reaction cell with He KED; three AGD modes for online matrix dilution
- Sub-ppt capability with AGD technology
- Inquire
Thermo Fisher Scientific
- Double-focusing magnetic sector (MC-ICP-MS); mass range 1–256 u; low/medium/high resolution modes; independent source and detector slit settings
- 10–20× increase in desolvation mode via jet interface
- High dynamic range with multi ion counting capability
Select up to 5 products from above to compare or request more information.