Inductively coupled plasma mass spectrometers (ICP-MS) utilize inductively coupled plasma for sample ionization and an MS for ion separation and quantification. The low detection limits and high productivity possible with ICP-MS are particularly useful for trace metal analysis and environmental testing. Common components of an ICP-MS system include a sample introduction system, an ion source, a vacuum system, a collision reaction cell, ion optics, a mass spectrometer (often a quadrupole), and a detector. An analytical working range of nine orders of magnitude, detection limits below the ppt range, and aptitude for isotopic analysis are hallmarks of ICP-MS. ICP-MS instruments are commonly configured for routine analyses, high-matrix interference samples, or specific applications, such as work in the semiconductor industry or medical and forensic toxicology fields. Also, be sure to consider any desired customization options, such as chromatographic coupling or use with organic solvents.
Find, compare, and request a quote for inductively coupled plasma mass spectrometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
Get Quote for All
Select up to 5 products from below to compare or request more information.
Nu Instruments
- Single-collector double-focusing magnetic sector; mass range 1–260 u
- Inquire
- 9 orders of magnitude (pulse-counting multiplier with patented beam attenuation); 12 orders of magnitude with optional Faraday detector
Nu Instruments
- Multi-collector double-focusing magnetic sector; 16 Faraday cups + up to 5 ion-counting detectors (SEM or Daly); mass range lithium to actinide series
- Inquire
- Inquire
Nu Instruments
- Multi-collector double-focusing magnetic sector; 16 Faraday cups + up to 6 ion-counting detectors (SEM or Daly); high-resolution and pseudo-high-resolution modes
- Inquire
- Inquire
Nu Instruments
- Multi-collector double-focusing magnetic sector with MS/MS capability; XD collector array with up to 28 Faraday cups + up to 6 ion-counting detectors (SEM or Daly); mass range Li to U and beyond; 25% natural dispersion; dynamic range 0–75 Gcps (SEM to 10^10 O pre-amplifier)
- Inquire
- 0–75 Gcps (0–1200 V) from SEM to 10^10 O resistor pre-amplifier
Nu Instruments
- Multi-collector double-focusing magnetic sector; 16 Faraday cups + up to 6 ion-counting detectors (SEM or Daly); mass range lithium to actinide series
- Inquire
- Inquire
Nu Instruments
- Time-of-Flight (TOF); simultaneous full-spectrum acquisition; acquisition rate 33 kHz (full mass range) to 160 kHz (reduced mass range); spectrum readout time as low as 80 µs
- Inquire
- 10 orders of magnitude (patented ion beam attenuation system combined with MagneTOF detector)