| Description | The all-Agilent ICP-MS Automation Systems set a new industry standard by seamlessly integrating key automation features into a single, easily configured package. Specifically designed for Agilent ICP-MS, these automation systems enhance sample throughput, free up operator time for other important The all-Agilent ICP-MS Automation Systems set a new industry standard by seamlessly integrating key automation features into a single, easily configured package. Specifically designed for Agilent ICP-MS, these automation systems enhance sample throughput, free up operator time for other important tasks, and reduce turnaround time on results, cost per sample, and the risk of human error.
Each system includes an Agilent ICP-MS instrument, an Advanced Valve System, an Advanced Dilution System, an SPS 4 autosampler, instrument software, and peace of mind in knowing that they are fully supported by Agilent. Choose between the 7850 ICP-MS Automation System and the 7900 ICP-MS Automation System, depending on your laboratory needs.
Features:
- Agilent’s smart ICP-MS instruments are simple to setup and offer fast, streamlined analysis with great results from even the most demanding applications
-
SPS 4 autosampler automates sample presentation for unattended analysis and is designed to meet the needs of high-throughput labs requiring a fast, high-capacity autosampler
-
Advanced Valve System (AVS MS) doubles the number of samples that can be measured in a day and reduces maintenance frequency
-
Advanced Dilution System (ADS 2) automates standard preparation and pre-run sample dilutions. Post-run dilution sample dilutions are eliminated via reactive dilutions during the analysis
-
Agilent ICP-MS Automation Systems include the SPS 4, AVS MS, and ADS 2 under a single part number, including ICP-MS instrument, ensuring a streamlined purchasing process
-
All-Agilent solution offers the convenience of dealing with only one company and the peace of mind in knowing that the complete system is fully supported and tested to Agilent’s strict QC requirements
-
Fully integrated software provides complete control over all automation accessories from a single interface, minimizing staff training. Includes software support for achieving 21CFR11 compliance
-
Increase lab sustainability with less argon, power, and labware usage. Automatic inline dilutions greatly reduce the need for plasticware, including pipette tips, and solution vials.
... Read More | Free your ICP-MS analysis with the Agilent 7850 ICP mass spectrometer from common time traps. It’s the smart way to reduce wasted time so busy staff can focus on tasks that deliver value. The 7850 ICP-MS is an ICP mass spectrometer that can handle samples with up to 25% solids, reducing the dilutionFree your ICP-MS analysis with the Agilent 7850 ICP mass spectrometer from common time traps. It’s the smart way to reduce wasted time so busy staff can focus on tasks that deliver value. The 7850 ICP-MS is an ICP mass spectrometer that can handle samples with up to 25% solids, reducing the dilution time trap. The instrument features a helium mode collision cell and half mass correction that removes both polyatomic and doubly charged ion interferences, simplifying method development and addressing a common cause of time-wasting sample remeasurement.
Check out how the Agilent 7850 ICP mass spectrometer boosts lab efficiency and helps reclaim wasted time throughout your ICP-MS analysis.
Features- Standard operating procedures and fully developed methods for regulated and routine methods save you weeks of method development and documentation time.
- Ultra High Matrix Introduction (UHMI) reduces sample preparation time by allowing you to directly analyze samples containing up to 25% total dissolved solids without dilution.
- Helium collision cell and half-mass correction remove troublesome polyatomic and doubly-charged interferences that can reduce data quality and increase the need for costly sample remeasurements.
- Robust hardware allows you to measure high matrix samples without having to matrix-match calibration standards.
- IntelliQuant gives you a complete elemental profile of each sample, helping you to easily identify unusual sample matrices.
- Outlier Conditional Formatting (OCF) reduces data review times for busy or inexperienced ICP-MS operators by highlighting results that are outside a nominated range or have failed a test requirement.
- Early Maintenance Feedback (EMF) uses sensors and counters to determine when maintenance is needed. Traffic light, color-coded alerts means maintenance tasks are never missed but are also not performed more frequently than necessary.
- ICP Go is an optional, browser-based user-interface for mobile devices offering simplified set up and control of routine sample batches and is great for ICP-MS operators on the move.
- Method-specific Analyzer packages containing ICP-MS hardware, software, consumables, professional services and documentation ensure you’ll be running samples in weeks, instead of the months it can take to develop, optimize, verify and document a regulated method.
... Read More | The Agilent 7900 ICP-MS is a flexible single quadrupole ICP mass spec instrument that provides the industry’s best matrix tolerance, most effective helium collision mode, lowest detection limits, and widest dynamic range. As a result, you can be confident you are reporting accurate data every time, The Agilent 7900 ICP-MS is a flexible single quadrupole ICP mass spec instrument that provides the industry’s best matrix tolerance, most effective helium collision mode, lowest detection limits, and widest dynamic range. As a result, you can be confident you are reporting accurate data every time, even at trace levels, whatever your sample types.
The 7900 ICP Mass Spec provides the highest performance for demanding commercial and industrial applications, with the high sensitivity and fast acquisition of transient signals – necessary for the analysis of single nanoparticles (spICP-MS), single cells, and for laser ablation. In addition, having the flexibility needed for research and advanced analysis, such as speciation, is sure to give you an edge over the competition.
Features- The industry’s most robust (low CeO/Ce) plasma delivers unprecedented matrix tolerance
- Ultra High Matrix Introduction (UHMI) technology enables you to run samples with 25% total dissolved solids (TDS)
- Helium (He) cell gas mode improves accuracy by providing reliable control of polyatomic interferences
- Off-axis lens provides high sensitivity and low detection limits across the mass range
- Wide dynamic range detector allows you to measure majors and trace in one run
- Fast integration (0.1 ms dwell time) supports analysis of fast transient signals such as single nanoparticles (spICP-MS)
- ICP-MS MassHunter Method Wizard builds your methods automatically
- Flexible configuration easily connects to optional accessories and peripherals for advanced applications
... Read More | The Agilent 8900 triple quadrupole ICP-MS (ICP-QQQ) is the world’s most successful and widely used tandem ICP mass spectrometer. Available in a range of configurations to cover applications from routine contract analysis to advanced research and high-purity materials analysis, the Agilent 8900 ICP-The Agilent 8900 triple quadrupole ICP-MS (ICP-QQQ) is the world’s most successful and widely used tandem ICP mass spectrometer. Available in a range of configurations to cover applications from routine contract analysis to advanced research and high-purity materials analysis, the Agilent 8900 ICP-QQQ redefines ICP-MS performance, delivering results you can trust.
The 8900 offers the same matrix tolerance and robustness as Agilent’s market-leading single quadrupole ICP-MS systems, combined with the industry’s most effective helium (He) collision mode. But the 8900 adds tandem mass spec operation (ICP-MS/MS) for unmatched control of reaction chemistry in the collision reaction cell (CRC), making it the world’s most powerful and flexible multi-element analyzer. Let the 8900 ICP-QQQ take control of your interferences and put your results beyond doubt.
Features- MS/MS controls the reaction chemistry ensuring consistent, reliable results, even for previously difficult elements like Si, P, and S
- Reaction chemistry resolves isobaric overlaps, which are beyond the capability of high-resolution ICP-MS
- Four-channel cell gas control provides fast, flexible, multi-mode operation
- A suite of pre-set methods simplifies method setup for routine analysis
- Helium mode provides simple, effective control of common polyatomic interferences
- Robust (low CeO/Ce) plasma for unmatched matrix tolerance
- Ultra High Matrix Introduction (UHMI) technology tolerates samples with up to 25% total dissolved solids (TDS)
- High sensitivity and low background provide the lowest detection limits for ultra trace analytes
- Versatility and high performance combine to support advanced research and demanding applications
- Flexible modes of operation (precursor/product ion scan) support research into reaction chemistry modes
... Read More | The Agilent 9500 Triple Quadrupole ICP-MS delivers true ICP-MS/MS performance without the complexity. Its proprietary Dual-Cell System, with Advanced Helium Mode (AHM) and Air mode, enables fast, interference-free analysis across complex matrices, delivering results you can trust.
Built for labs The Agilent 9500 Triple Quadrupole ICP-MS delivers true ICP-MS/MS performance without the complexity. Its proprietary Dual-Cell System, with Advanced Helium Mode (AHM) and Air mode, enables fast, interference-free analysis across complex matrices, delivering results you can trust.
Built for labs that need higher performance without workflow disruption, the 9500 ICP-QQQ simplifies method development and routine analysis. AHM replaces multiple tune modes to cut acquisition time by >33%, while Air cell uses ambient air to remove difficult interferences.
Features:
- Proprietary Dual-Cell System (DCS) combines Advanced Helium Mode and Air mode for simple, powerful interference removal across complex sample matrices
-
Advanced Helium Mode replaces multiple tune modes with one streamlined mode, reducing acquisition time by more than 33% for faster routine analysis
-
Air cell uses ambient air for oxygen mass-shift reactions, resolving difficult on-mass interferences while eliminating extra reactive gas infrastructure and related safety concerns
-
DCS with AHM combines Collision-Induced Dissociation (CID) and Kinetic Energy Discrimination (KED) in a single high-performance mode for powerful interference removal while maintaining low mass sensitivity
-
Preset methods, Method Advisor, and automated method conversion tools simplify method setup and make ICP-QQQ more accessible for routine analysis
-
Single quadrupole familiarity with triple quadrupole capability–less to learn, while achieving more
-
Improved hardware design enhances performance and usability, including a new u-lens, Q2 mass range extended to 300 u, and a 0.05 ms minimum dwell time
-
Easy-fit sample introduction, improved accessibility, and ergonomic design simplify installation and maintenance, reducing manual effort and supporting reliable day-to-day operation
-
Integrated Agilent automation options support higher productivity through unattended analysis, automated dilution and calibration, and lower cost per sample
... Read More |