Computed tomography utilizes a motorized X-ray source that rotates around a gantry to capture a series of tomographic images that can be layered to generate an extremely accurate 3D image. Laboratory computed tomography instruments are used extensively for NDT testing and are capable of accurately imaging the entirety of a material. When comparing laboratory CT devices, scan times can be of paramount importance for keeping up with your throughput. Also, consider the detector of the CT device. Flat panel detectors tend to offer increased longevity and size, whereas CMOS detectors can offer increased scanning speed with improved resolution. Laboratory computed tomography devices are offered in several sizes ranging from benchtop to floor-standing models, the right choice will vary depending on laboratory space as well as the size of the object to be imaged.
|  |  |  |
| Company | Rigaku Corporation | Rigaku Corporation | Rigaku Corporation |
| Item | CT Lab HX | CT Lab HV CT Scanner | nano3DX High-Resolution microCT |
| Catalog Number | CT Lab HX | CT Lab HV | nano3DX |
| Price | | | |
| Type | Benchtop | Industrial | Inquire |
| Dimensions | (WxDxH) 980 x 700 x 580 mm (PC not included) | (WxDxH) 2250 × 1800 x 2150 mm (PC, chiller not included) | (W×H×D) 1300 × 1880 × 655 mm (PC, chiller, vacuum pump not included) |
| Sample Size | 200 mm diameter x 270 mm height | Maximum size of 600 mm diameter x 1200 mm height | Maximum size of 20 mm diameter x 40 mm height |
| Description | Versatile X-ray Micro CT Scanner
Rigaku CT Lab HX is a benchtop micro CT (computed tomography) scanner. The adjustable SOD (source-to-object distance) and SDD (source-to-detector distance) make this benchtop micro CT scanner flexible. It covers from 2.1-micron voxel resolution in the high-Versatile X-ray Micro CT Scanner
Rigaku CT Lab HX is a benchtop micro CT (computed tomography) scanner. The adjustable SOD (source-to-object distance) and SDD (source-to-detector distance) make this benchtop micro CT scanner flexible. It covers from 2.1-micron voxel resolution in the high-resolution mode and 200 mm FOV (field of view) in the large FOV mode. The CT Lab HX is equipped with a 130 kV - 39 W high-power X-ray source. The X-ray source settings and X-ray filters are adjustable to optimize the X-ray energy to various sample materials and sizes.
Features: - Flexible design to cover high-resolution to large FOV
Adjustable source to object and detector distances to optimize the geometry for a variety of resolutions and FOV needs - 2.1 um voxel / 5 um spatial resolution
High-resolution geometry by the long source to detector distance - 200 mm FOV
Offset scan mode doubles the effective detector size to cover a large FOV ... Read More | Rigaku CT Lab HV is a high-resolution and high-voltage industrial X-ray CT (computed tomography) scanner. The large radiation enclosure, wide door opening, 225 kV high-voltage X-ray source, and variable SOD (source-to-object distance) and SDD (source-to-detector distance) provide the ultimate Rigaku CT Lab HV is a high-resolution and high-voltage industrial X-ray CT (computed tomography) scanner. The large radiation enclosure, wide door opening, 225 kV high-voltage X-ray source, and variable SOD (source-to-object distance) and SDD (source-to-detector distance) provide the ultimate flexibility to scan small to large samples, up to 600 mm in diameter ×1200 mm in height with a 350 mm FOV (field of view) non-destructively. The high-resolution setting achieves true 3-micron spatial resolution. Our unrivaled technical support will help you utilize state-of-the-art analysis and simulation techniques.... Read More | Rigaku nano3DX is a true submicron resolution microCT scanner (micro computed tomography). The parallel beam geometry combined with an ultra-bright 1200 W rotating anode X-ray source enhances the contrast of low-density materials, which are normally difficult to image using high-energy X-ray sourcesRigaku nano3DX is a true submicron resolution microCT scanner (micro computed tomography). The parallel beam geometry combined with an ultra-bright 1200 W rotating anode X-ray source enhances the contrast of low-density materials, which are normally difficult to image using high-energy X-ray sources.
This parallel beam geometry in combination with an optical lens produces high-resolution 3D images. Furthermore, it avoids blurring which is commonly encountered using X-ray beam divergent imaging techniques.
The X-ray anode can be selected from Cr (5.4 keV), Cu (8 keV), or Mo (17 keV). These anode materials generate low-energy and pseudo-monochromatic radiation to maximize the X-ray CT image contrast. The anode material can be selected with the click of a button depending on the sample material and size. With the highest magnification lens, the nano3DX can achieve 325 nm voxel resolution and true submicron (700 nm) spatial resolution, with no sample preparation.
Key features - Parallel beam geometry for true submicron resolution
- Selectable pseudo-monochromatic X-ray radiations
- Ultra-bright 1200 W X-ray source and sCMOS for shorter scan time – as short as 30sec
... Read More |
| Detector(s) | Flat panel; Detector pixel size 49.5 microns | Flatpanel | High-resolution sCMOS |
| Scan Time | Shortest scan time 18 seconds | The shortest scan time 1 mon | Shortest scan time of 30 sec |
| Applications | - Rocks and geological samples
- 3D printed components
- Electronics
- Plastics
- Ceramics
- Light metals and alloys
- Composite materials – Carbon and glass fiber reinforces plastics (CFRP and GFRP)
- Foams and other porous materials
- Pharmaceuticals
- Pore size and distribution analysis
- Non-destructive submicron analysis
- Analysis of seeds, grains
| - Inspection of batteries
- Inspection of electronic devices
- 3D printed objects
- Polymer and plastic objects
- Metal parts
- Medical devices
| - Composite materials – Carbon and glass fiber reinforces plastics (CFRP and GFRP)
- Foams and other porous materials
- Pharmaceuticals
- Pore size and distribution analysis
- Non-destructive submicron analysis of organic materials
- Analysis of seeds, grains
|
| Get Quote | | | |