Material and petrochemical research utilizes a wide range of lubricant testing equipment to test lubricant flashpoint, viscosity, purity, volatility, cold properties, Noack as well as other oxidation tests. Essential to modern machinery, lubricant testing equipment is necessary to ensure predetermined standards are met and utilize methods like FTIR. Key considerations are primarily directed by application parameters, measurement time, sample volume and footprint.
|  |  |  |  |  |
| Company | eralytics GmbH | eralytics GmbH | eralytics GmbH | eralytics GmbH | eralytics GmbH |
| Item | ERACHECK ECO Oil-in-Water Tester | ERACOUNT XS Laser Particle Counter | ERADENS X High-precision Density Meter | ERAFLASH LT Flash Point Tester | ERAVAP ONLINE Vapor Pressure Analyzer |
| Reviews | | | | | |
| Catalog Number | ECO01 | ERACOUNT XS | ERADENS X | EF02 | EP10 |
| Price | | | | | |
| Description | Eco-Efficient Oil-in-Water Testing
The CFC-free oil-in-water tester ERACHECK ECO easily measures the concentration of total oil and grease (TOG) and total petroleum hydrocarbons (TPH) in water and soil with sub-ppm precision. They deliver consistent results over a wide range of crude types using Eco-Efficient Oil-in-Water Testing
The CFC-free oil-in-water tester ERACHECK ECO easily measures the concentration of total oil and grease (TOG) and total petroleum hydrocarbons (TPH) in water and soil with sub-ppm precision. They deliver consistent results over a wide range of crude types using the CFC-free solvent cyclohexane for the extraction.
Features
- Measurement based on a non-dispersive IR transmission technology (D8193)
- MDL of 0.5 mg/L
- No loss of light ends of samples
- Easy creation of user calibrations
- ASTM D8193, D7678, D7066, ISO9377, EPA 1664
... Read More | The Fastest ISO 4406 Laser Particle Counter RACOUNT XS is the smallest and fastest field particle counter. At the push of a button, the laser-based analyzer measures and displays the ISO 4406 particle size channels ≥ 4 µm(c), ≥ 6 µm(c) and ≥ 14 µm(c) – all within 60 seconds using The Fastest ISO 4406 Laser Particle Counter RACOUNT XS is the smallest and fastest field particle counter. At the push of a button, the laser-based analyzer measures and displays the ISO 4406 particle size channels ≥ 4 µm(c), ≥ 6 µm(c) and ≥ 14 µm(c) – all within 60 seconds using only 10 mL of sample.
Your features at a glance:
- 10mL sample volume
-
Measurement up to 8 different size channels when connected to one of eralytics’ other OCM analyzers.
-
Flow rate 10 ml/min
-
Robust, full-metal device with only 3 kg of weight
-
Ideal for many applications: hydraulic & lube oils, fuels
... Read More | ERADENS X is the world’s smallest and lightest high-precision density meter measuring in full compliance with ASTM D4052 and ISO 12185. Its revolutionary vertically aligned x-oscillating metal U-tube design is extremely reliable and insensitive to toughest ambient conditions, making ERADENS X the ERADENS X is the world’s smallest and lightest high-precision density meter measuring in full compliance with ASTM D4052 and ISO 12185. Its revolutionary vertically aligned x-oscillating metal U-tube design is extremely reliable and insensitive to toughest ambient conditions, making ERADENS X the perfect solution for density testing in stationary as well as in mobile laboratories.
Features:
- Large industry-proven color touchscreen
- Unique sample introduction from the top, equally easy to operate for right-handed and left-handed persons
- Corrosion-resistant, extremely robust aluminum housing
- Compact dimensions and lightweight instrument design
- The x-oscillating metal U-tube technology inside, provides density results with 5-digit precision
- Full range viscosity correction ensures highest possible accuracy over the wide temperature range of 0 – 100 °C.
- Patented FillingProof™ Technology for the verification of the bubble-free filling
... Read More | The cool side of flash point testing
ERAFLASH LT is based on the unrivaled high performance of the other ERAFLASH flash point testers. However, it offers new benefits for fast low temperature flash point testing. Its enhanced cooling system allows decreasing the measurement temperature down to 35 °C The cool side of flash point testing
ERAFLASH LT is based on the unrivaled high performance of the other ERAFLASH flash point testers. However, it offers new benefits for fast low temperature flash point testing. Its enhanced cooling system allows decreasing the measurement temperature down to 35 °C below the ambient temperature without any external cooling. In addition it is the first flash point tester on the market that allows to use ASTM D7094 down to -40 °C (-40 °F) oven temperature with external cooling.
Features: - Maximum safety – no flame, no glowing wires, no fire hazard
- Cost efficient measurement by using just 1 or 2 mL sample
- Low temperature flash point testing between -40 and 120 °C (-40°F – 248°F) oven temperature
- High-speed measurements at low temperatures using a stacked Peltier design
- Compact and easy-to-use stand-alone analyzer with easy LIMS integration
... Read More | Vapor Pressure Testing at its Best
The process vapor pressure tester ERAVAP ONLINE is the most accurate and reliable vapor pressure tester on the market, always compliant with the latest international standards. ERAVAP ONLINE features the same measurement cell as the laboratory instrument ERAVAP, Vapor Pressure Testing at its Best
The process vapor pressure tester ERAVAP ONLINE is the most accurate and reliable vapor pressure tester on the market, always compliant with the latest international standards. ERAVAP ONLINE features the same measurement cell as the laboratory instrument ERAVAP, ensuring lab-grade results at any time.
Features
- UL Class 1, Div 1 & 2, Zone 1, ATEX and IECEx certi? ed
- Unmatched precision & accuracy (r=0.15 kPa / R=0.5 kPa)
- Three sample streams and one quality control stream
- Ex-proof 15"" color touchscreen
- Ruggedized for 24/7 operation
- ASTM D5191, D6378, D5188, D6377, D4052, etc
... Read More |
| Method | Inquire | Inquire | Inquire | Inquire | Inquire |
| Temperature Range | Inquire | Inquire | Inquire | Inquire | Inquire |
| Dimensions | Inquire | Inquire | Inquire | Inquire | Inquire |
| Type | Inquire | Laser Particle Counter | Density Meter | (Modified) Continuously Closed Cup | Mini Method |
| Measuring Time | Inquire | Inquire | Inquire | Inquire | Inquire |
| Sample Volume | Typically 900 mL water and 50 mL cyclohexane (min. 10 mL solvent required per measurement) | 5 ml at 10 ml/min, 12.5 ml at 25 ml/min | 2 mL | Inquire | Inquire |
| Get Quote | | | | | |