Material and petrochemical research utilizes a wide range of lubricant testing equipment to test lubricant flashpoint, viscosity, purity, volatility, cold properties, Noack as well as other oxidation tests. Essential to modern machinery, lubricant testing equipment is necessary to ensure predetermined standards are met and utilize methods like FTIR. Key considerations are primarily directed by application parameters, measurement time, sample volume and footprint.
|  |  |  |  |  |
| Company | eralytics GmbH | eralytics GmbH | eralytics GmbH | eralytics GmbH | eralytics GmbH |
| Item | ERAFLASH X Flash Point Tester | ERACHECK ECO Oil-in-Water Tester | ERACOUNT XS Laser Particle Counter | ERAFLASH S10 Flash Point Tester | ERATEST FERRO Ferrous Debris Analyzer |
| Catalog Number | ERAFLASH X | ECO01 | ERACOUNT XS | EFS01 | ERATEST FERRO |
| Price | | | | | |
| Description | The future-proof replacement for D93 Pensky-Martens testers
The flash point tester ERAFLASH X is the future-proof replacement for ASTM D93 Pensky-Martens testers. Tailored for the petroleum industry all kinds of liquids can be tested over the wide temperature range of 18 °C to 370 °C using only 2The future-proof replacement for D93 Pensky-Martens testers
The flash point tester ERAFLASH X is the future-proof replacement for ASTM D93 Pensky-Martens testers. Tailored for the petroleum industry all kinds of liquids can be tested over the wide temperature range of 18 °C to 370 °C using only 2 mL of sample. The full compliance with the latest flash point standard ASTM D7094 brings 100% safety, unrivalled speed as well as best in class precision to your laboratory.
The unique features of ERAFLASH X at a glance:
- No open ignition source
-
2 mL sample needed
-
ASTM D7094 & IP 620 compliant
-
PBT- Peltier Boost Technology™
-
ASTM D7094-23 offers best in class precision
-
Contamination Prevention Technology™
... Read More | Eco-Efficient Oil-in-Water Testing
The CFC-free oil-in-water tester ERACHECK ECO easily measures the concentration of total oil and grease (TOG) and total petroleum hydrocarbons (TPH) in water and soil with sub-ppm precision. They deliver consistent results over a wide range of crude types using Eco-Efficient Oil-in-Water Testing
The CFC-free oil-in-water tester ERACHECK ECO easily measures the concentration of total oil and grease (TOG) and total petroleum hydrocarbons (TPH) in water and soil with sub-ppm precision. They deliver consistent results over a wide range of crude types using the CFC-free solvent cyclohexane for the extraction.
Features
- Measurement based on a non-dispersive IR transmission technology (D8193)
- MDL of 0.5 mg/L
- No loss of light ends of samples
- Easy creation of user calibrations
- ASTM D8193, D7678, D7066, ISO9377, EPA 1664
... Read More | The Fastest ISO 4406 Laser Particle Counter RACOUNT XS is the smallest and fastest field particle counter. At the push of a button, the laser-based analyzer measures and displays the ISO 4406 particle size channels ≥ 4 µm(c), ≥ 6 µm(c) and ≥ 14 µm(c) – all within 60 seconds using The Fastest ISO 4406 Laser Particle Counter RACOUNT XS is the smallest and fastest field particle counter. At the push of a button, the laser-based analyzer measures and displays the ISO 4406 particle size channels ≥ 4 µm(c), ≥ 6 µm(c) and ≥ 14 µm(c) – all within 60 seconds using only 10 mL of sample.
Your features at a glance:
- 10mL sample volume
-
Measurement up to 8 different size channels when connected to one of eralytics’ other OCM analyzers.
-
Flow rate 10 ml/min
-
Robust, full-metal device with only 3 kg of weight
-
Ideal for many applications: hydraulic & lube oils, fuels
... Read More | The Automated Side of Safe Flash Point Testing
ERAFLASH and the autosampler ERAFLASH S10 with the inherently safe Continuously Closed Cup method guarantee maximum safety and speed. The small volume of 1-2 mL makes both instruments ideal for various applications like fuels, lube oils, paints, The Automated Side of Safe Flash Point Testing
ERAFLASH and the autosampler ERAFLASH S10 with the inherently safe Continuously Closed Cup method guarantee maximum safety and speed. The small volume of 1-2 mL makes both instruments ideal for various applications like fuels, lube oils, paints, flavors & ragrances and many more. They cover an unprecedented temperature range from -25 °C to 420 °C (-13 °F to 788 °F).
Features
- Automated analysis of up to 10 samples within 90 minutes
- PBT - Peltier Boost TechnologyTM for maximum speed & range
- Optional cooling lid
- Contamination Prevention TechnologyTM
- ASTM D7094, D6450, D93c, D56c, IP620, etc.
... Read More | Outstanding ferrous debris quantification
The ferrous debris analyzer ERATEST FERRO is a mobile and battery-operated measuring instrument for determining the total content of ferromagnetic wear particles in oils or greases samples within only one second. The instrument operates according to ASTM Outstanding ferrous debris quantification
The ferrous debris analyzer ERATEST FERRO is a mobile and battery-operated measuring instrument for determining the total content of ferromagnetic wear particles in oils or greases samples within only one second. The instrument operates according to ASTM D8120 and provides the precise concentration in ppm of magnetizable debris with only 2 mL of sample. ERATEST FERRO is supplied inside a rugged transport case and is fit to deliver the best possible results in any environment.
Your features at a glance:
- Only 2 mL sample volume
-
Measurement result in 1 second
-
5” color touch screen with brilliant resolution
-
Lithium battery for minimum 5 hours of independent operation
-
Outstanding software featured for trending and asset management
... Read More |
| Method | Inquire | Inquire | Inquire | Inquire | Inquire |
| Dimensions | Inquire | Inquire | Inquire | Inquire | (WxDxH) 22 x 25 x 13 cm (6.7 x 9.8 x 5.1 in) |
| Type | (Modified) Continuously Closed Cup | Inquire | Laser Particle Counter | (Modified) Continuously Closed Cup | Inquire |
| Measuring Time | Inquire | Inquire | Inquire | Inquire | 1 second |
| Sample Volume | Inquire | Typically 900 mL water and 50 mL cyclohexane (min. 10 mL solvent required per measurement) | 5 ml at 10 ml/min, 12.5 ml at 25 ml/min | Inquire | 2 mL |
| Get Quote | | | | | |