| Spectral Bandwidth | UV-Vis 0.01 to 5.00 nm; NIR 0.04 to 20 nm | Excitation: 1.5, 2.5, 5, 10, 20 nm and 10 nm round. Emission: 1.5, 2.5, 5, 10, 20 nm and 10 nm round |
| Description | The Agilent Cary 7000 universal measurement spectrophotometer (UMS) will satisfy all your solid sampling needs. Collect hundreds of UV-Vis-NIR spectra overnight or characterize optical components and thin films in minutes to hours rather than hours to days. The Cary 7000 UMS is a turn-key solution The Agilent Cary 7000 universal measurement spectrophotometer (UMS) will satisfy all your solid sampling needs. Collect hundreds of UV-Vis-NIR spectra overnight or characterize optical components and thin films in minutes to hours rather than hours to days. The Cary 7000 UMS is a turn-key solution for research, development, and QA/QC in optics, thin films/coatings, solar, and glass.
The Cary 7000 instrument's multiangle specular reflectance and transmittance capabilities allow you to design experiments never before possible—expanding your research—while the automated reflectance and transmission will save you time and money.
Features - Achieve complete sample characterization
- Measure absolute reflection and transmission in a single sequence—at variable angle and s or p polarization—without moving or disturbing the sample.
- Measure diffusely scattered transmission and reflection with the freedom to control detector and sample position independently
- Utilize the huge sample chamber to accommodate all sample types—from small to large—delivering 360 degrees of rotational flexibility
- Obtain complete control of beam collimation and patch size to best suit your sample and measurement needs
- Lower your cost-per-analysis, saving you time and money
- Measure in minutes what other systems take hours to days to complete—with unattended automation
- Simply set up your method, collect a single baseline, insert one or more samples, and walk away
- New insights into advanced materials with an unprecedented 10 Abs range
- With 10 Abs range on the Cary 7000 spectrophotometer, the Cary 7000 UMS ensures you obtain high quality results even with challenging sample measurements, such as high optical density (OD) or under difficult measurement conditions
- Obtain the highest quality results fast with the next generation Cary WinUV software
- The Cary WinUV software features a new method editor for simple method setup, advanced data processing, and 3D graphics, ensuring fast and accurate data analysis
... Read More | The Agilent Cary Eclipse fluorescence spectrophotometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be The Agilent Cary Eclipse fluorescence spectrophotometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be achieved through various accessories, including temperature control and solid sample handling, automatic polarizers, and a microplate reader for high sample throughput.
The Cary Eclipse is ideal for fluorescent measurements in life sciences and biotechnology, with high sensitivity and inherent bleaching protection for photosensitive samples. Fast data collection enables kinetics measurements, while fiber optics allow for remote sample measurements.
Features - Flexible fluorescence spectrometer with multiple data collection modes including fluorescence, phosphorescence, chemiluminescence, bioluminescence, and time resolved phosphorescence.
- Robust and reliable performance backed up by a 10-year lamp life guarantee (for new Cary Eclipse systems purchased from Agilent or participating partners).
- Low cost-of-ownership due to the guaranteed long lifetime of the Cary Eclipse fluorometer lamp. This also eliminates the need for lamp replacements, a time-consuming and hazardous waste-producing technical operation.
- Easy-to-use Cary WinFLR software suitable for novice and expert users alike. Easily switch between measurement modes without touching the hardware, and quickly get reliable, accurate results.
- Room light immunity provided by a unique design allows the instrument to operate with the front and top panels removed—for easy access to samples and fast installation of large accessories, expanding analytical capabilities.
- Performance and sensitivity that you need right across the fluorescence spectrum due to high-sensitivity optics and detectors.
- High throughput laboratories and fast kinetics applications are well suited to the Cary Eclipse, as its xenon flash lamp allows the instrument to capture a data point every 12.5 ms, and scan at 24,000 nm/min without peak shifts.
- Sampling flexibility enables a wide range of fluorescence applications, with accessories available for every sample type—liquids, solids, and powders. Polarizers and temperature control are also available.
- Inherent protection from photodegradation, as the Cary Eclipse only illuminates the sample when data is actually being acquired. This protects your valuable samples so you can measure them repeatedly and get the same, reliable results.
... Read More |