| Spectral Bandwidth | 1.5 nm fixed | Excitation: 1.5, 2.5, 5, 10, 20 nm and 10 nm round. Emission: 1.5, 2.5, 5, 10, 20 nm and 10 nm round |
| Description | The Cary 60 UV-Vis spectrophotometer has a wavelength range of 190–1100 nm that can be scanned in under three seconds. Our flexible UV-Vis system can be fitted with long pathlength cuvettes and solid sample transmission or reflectance accessories, and is ideal for remote UV-Vis absorbance analysis, The Cary 60 UV-Vis spectrophotometer has a wavelength range of 190–1100 nm that can be scanned in under three seconds. Our flexible UV-Vis system can be fitted with long pathlength cuvettes and solid sample transmission or reflectance accessories, and is ideal for remote UV-Vis absorbance analysis, when fitted with fiber optic probes.
The xenon source lamp has a 10 year replacement warranty (for Cary 60 instruments purchased from Agilent or participating partners), requires zero warmup, and causes no photodegradation of samples. Fast reactions can be recorded with 80 data points per second. The Cary 60 is well-suited as a routine UV-Vis spectrophotometer or for use in teaching labs. Optional 21 CFR Part 11 software tools are available.
Features - Reduce time-consuming and expensive lamp replacements, and minimize instrument revalidation costs with the unique Agilent xenon source lamp.
- Safely measure life-science samples without sample photodegradation and ensure you get the correct answer every time with the Cary 60 UV-Vis spectrophotometer.
- Get reliable UV-Vis spectrophotometer performance with fiber-optic measurement probes. Why use cuvettes when you can bring the UV-Vis instrument to the sample and get accurate results in a fraction of the time?
- Measure small volumes and precious samples accurately and reproducibly with a highly focused beam image.
- Scan the entire wavelength range (190 to 1100 nm) in under three seconds and collect data from single or multiple wavelengths at 80 data points per second.
- Take advantage of the Cary 60 UV-Vis spectrophotometer’s comprehensive range of accessories to accurately characterize the widest variety of liquid and solid samples.
- Tailor the Cary WinUV software to suit your analytical requirements. From classroom to research laboratories through R&D and regulated QA/QC environments, simplify your UV-Vis spectroscopy measurements and finish more in less time.
- Choose sustainability: The Cary 60 UV-Vis received My Green Lab’s ACT (Accountability, Consistency, Transparency) label after an independent audit for its environmental impact throughout the product lifecycle.
... Read More | The Agilent Cary Eclipse fluorescence spectrophotometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be The Agilent Cary Eclipse fluorescence spectrophotometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be achieved through various accessories, including temperature control and solid sample handling, automatic polarizers, and a microplate reader for high sample throughput.
The Cary Eclipse is ideal for fluorescent measurements in life sciences and biotechnology, with high sensitivity and inherent bleaching protection for photosensitive samples. Fast data collection enables kinetics measurements, while fiber optics allow for remote sample measurements.
Features - Flexible fluorescence spectrometer with multiple data collection modes including fluorescence, phosphorescence, chemiluminescence, bioluminescence, and time resolved phosphorescence.
- Robust and reliable performance backed up by a 10-year lamp life guarantee (for new Cary Eclipse systems purchased from Agilent or participating partners).
- Low cost-of-ownership due to the guaranteed long lifetime of the Cary Eclipse fluorometer lamp. This also eliminates the need for lamp replacements, a time-consuming and hazardous waste-producing technical operation.
- Easy-to-use Cary WinFLR software suitable for novice and expert users alike. Easily switch between measurement modes without touching the hardware, and quickly get reliable, accurate results.
- Room light immunity provided by a unique design allows the instrument to operate with the front and top panels removed—for easy access to samples and fast installation of large accessories, expanding analytical capabilities.
- Performance and sensitivity that you need right across the fluorescence spectrum due to high-sensitivity optics and detectors.
- High throughput laboratories and fast kinetics applications are well suited to the Cary Eclipse, as its xenon flash lamp allows the instrument to capture a data point every 12.5 ms, and scan at 24,000 nm/min without peak shifts.
- Sampling flexibility enables a wide range of fluorescence applications, with accessories available for every sample type—liquids, solids, and powders. Polarizers and temperature control are also available.
- Inherent protection from photodegradation, as the Cary Eclipse only illuminates the sample when data is actually being acquired. This protects your valuable samples so you can measure them repeatedly and get the same, reliable results.
... Read More |