| Description | The Shimadzu BioSpec-nano is a low-maintenance micro-volume spectrophotometer designed for the modern life science laboratory. It offers superior detection limits, up to 10 times better compared to the competition, making it the perfect instrument for quantitation of DNA, RNA, protein analysis, and The Shimadzu BioSpec-nano is a low-maintenance micro-volume spectrophotometer designed for the modern life science laboratory. It offers superior detection limits, up to 10 times better compared to the competition, making it the perfect instrument for quantitation of DNA, RNA, protein analysis, and photometric measurements. Quantitation can be rapidly and simply carried out with very small samples ranging from 1µL. And, with dedicated functions, such as automated sample mounting and wiping, the BioSpec-nano offers a rapid 3-second analysis time and a 10-second cycle time between samples. Features Ultra-small Sample Volumes Perform analysis with 1µL to 2µL samples. For ultra-small sample volumes no standard rectangular cell is needed although for applications that are not volume-limited, an optional rectangular cell adapter is available. Automated Analysis With “drop-and-click” functionality, analysis has never been easier. Simply drop the sample onto the target and click the button. Easy Operation/Maintenance Sample mounting, measurement and cleaning are conducted by the instrument, eliminating the need for operators to perform the tedious, repetitive, and inconsistent placement of the fiber optic element and manual cleaning required in other instruments. Speed Measurement takes seconds, and a series of samples can be analyzed while confirming spectra in the Detail view mode. Specifications Measuring wavelength range: 220 to 800 nm Spectrum band width: 3 nm Wavelength accuracy: ± 1 nm Pathlength: 0.2 mm, 0.7 mm (manual selection) Light source: Xenon flash lamp Monochrometer: Holographic grating Detector: Photo diode array Auto wiping function: Provided Sample mount function: Auto Quantitation range: (OD, dsDNA concentration) Pathlength 0.2 mm, 1 to 75 OD (50 to 3,700 ng / µL) Pathlength 0.7 mm, 0.3 to 21 OD (15 to 1,000 ng / µL) Optional 5 mm pathlength cell, 0.04 to 3 OD (2 to 150 ng / µL) ... Read More | The FTIR Plastic Analysis System includes proprietary UV- and thermal-damaged plastics libraries to facilitate highly accurate qualification and state of deterioration when analyzing foreign substances, contaminants, and microplastics. The system is comprised of the compact IRSpirit FTIR The FTIR Plastic Analysis System includes proprietary UV- and thermal-damaged plastics libraries to facilitate highly accurate qualification and state of deterioration when analyzing foreign substances, contaminants, and microplastics. The system is comprised of the compact IRSpirit FTIR spectrophotometer, QATR-S single-reflection ATR attachment, and the Plastic Analyzer Method Package. The Plastic Analyzer method package includes FTIR spectral libraries for plastics degraded by UV rays and heat.
UV-damaged plastics library – includes more than 200 spectra from the UV degradation of 14 types of plastics, unirradiated and UV irradiated for 1 to 550 hours. Thermal-damaged plastics library – includes more than 100 spectra from the degradation of 13 types of plastic heated to between 200 °C and 400 °C. The system also includes plastic measurement parameters and a special program that simplifies spectral measurements and the creation of reports, enabling analysts to easily perform everything from the measurement of target samples to data analysis.... Read More | Shimadzu’s IRXross™ Fourier Transform Infrared (FTIR) Spectrophotometer is a mid-level FTIR model that achieves upper-end performance, including high-level S/N ratio, resolution, measurement speed and ease of use. This robust, reliable system features built-in Analytical Intelligence, compliesShimadzu’s IRXross™ Fourier Transform Infrared (FTIR) Spectrophotometer is a mid-level FTIR model that achieves upper-end performance, including high-level S/N ratio, resolution, measurement speed and ease of use. This robust, reliable system features built-in Analytical Intelligence, complies fully with applicable regulations, and can be equipped with a variety of accessories and options, including an infrared microscope, to meet a wide range of applications.
Features - With P-P values of 55,000:1 for one minute of integration, the IRXross delivers ultra-high-sensitivity measurements.
- High-resolution 0.25 cm-1 measurements.
- High-speed measurement of 20 spectra per second enables faster reaction tracking.
- Built-in IR Pilot™ features 23 macro application programs, allowing even unexperienced operators to analyze samples easily.
- Program for supporting identification testing makes pass/fail judgments for test samples based on verification methods specified in pharmacopoeia and official methods specified in respective countries.
- Contaminant analysis program can accurately identify measured contaminants using Shimadzu’s proprietary algorithm (patent No. 5205918) in combination with a spectral library containing more than 550 spectra for substances commonly detected as contaminants.
- Wide variety of libraries, including Shimadzu’s unique libraries, reagents, polymers and more, is included standard.
- Numerous optional accessories and software programs available to meet specification application requirements.
LabSolutions™ Software DB IR and LabSolutions CS IR meet the requirements of Electronic Record and Electronic Signature regulations. In addition, the software includes built-in validation test macros for compliance with requirements from various pharmacopeia, including USP.... Read More | The compact UV-2600i Plus is a universal, research-grade spectrophotometer that can be used in a wide range of fields, and easily expanded to suit the measurement objective. By using the optional integrating sphere, the measurement wavelength range of the UV-2600i Plus can be extended to the near-The compact UV-2600i Plus is a universal, research-grade spectrophotometer that can be used in a wide range of fields, and easily expanded to suit the measurement objective. By using the optional integrating sphere, the measurement wavelength range of the UV-2600i Plus can be extended to the near-infrared region of 1400 nm.
Validation software is provided as standard for the instrument, so equipment performance can be easily checked in daily inspections and when data accuracy becomes a concern.
Features:
- Equipped with a single monochromator, providing low noise performance across a wide wavelength range
-
Enables near-infrared measurements (up to 1400 nm)
-
Stray light levels as low as 0.005 %
-
A compact 450 mm width size, reducing the required installation space by 28 %
-
Achieves 10 % energy savings compared to other Shimadzu systems
-
Validation software is included as standard
-
Freely expandable to suit the measurement objective
-
Automated data processing
The system incorporates Analytical Intelligence functions for improved operation. The Assist Function notifies the user when attempting to implement measurements without making necessary corrections, helping to ensure analyses are performed using the correct procedure. By specifying various evaluation criteria for measurement results, the Spectral Evaluation Function enables spectra judgments to be made automatically. The Shutdown/Wakeup Function allows the instrument to be put into sleep mode, limiting power consumption, and be set to wake up automatically at a specified time, enabling analysis to start the instant the user arrives at the laboratory.
LabSolutions UV-Vis control software is included with the UV-2600i Plus. Measurement modes include photometric, spectrum, quantitation, kinetics, time course and bio-methods. With a proper software compliance package, the UV-2600i and the software setup can provide total data integrity, users administration and audit trail to fully comply with FDA 21 CFR Part 11 compliance.... Read More | The compact UV-2700i Plus is a double monochromator system offering ultra-low stray light (0.00002 %). This model can measure high absorbance levels up to 8 Abs, allowing it to measure low transmittance levels in highly concentrated samples, films, or other samples with low transmittance The compact UV-2700i Plus is a double monochromator system offering ultra-low stray light (0.00002 %). This model can measure high absorbance levels up to 8 Abs, allowing it to measure low transmittance levels in highly concentrated samples, films, or other samples with low transmittance characteristics.
Validation software is provided as standard for the instrument, so equipment performance can be easily checked in daily inspections and when data accuracy becomes a concern.
Features:
- Equipped with an ultra-low stray light double monochromator, capable of 8-Abs measurements
-
Uses the Shimadzu proprietary Lo-Ray-Ligh grade diffraction grating
-
A compact 450 mm width size, reducing the required installation space by 28 %
-
Achieves 10 % energy savings compared to other Shimadzu systems
-
Validation software is included as standard
-
Freely expandable to suit the measurement objective
-
Automated data processing
The system incorporates Analytical Intelligence functions for improved operation. The Assist Function notifies the user when attempting to implement measurements without making necessary corrections, helping to ensure analyses are performed using the correct procedure. By specifying various evaluation criteria for measurement results, the Spectral Evaluation Function enables spectra judgments to be made automatically. The Shutdown/Wakeup Function allows the instrument to be put into sleep mode, limiting power consumption, and be set to wake up automatically at a specified time, enabling analysis to start the instant the user arrives at the laboratory.
LabSolutions UV-Vis control software is included with the UV-2700i Plus. Measurement modes include photometric, spectrum, quantitation, kinetics, time course and bio-methods. Optional software programs are available. With a proper software compliance package, the UV-2700i Plus and the software setup can provide total data integrity and full support for Pharmacopeia (JP, USP and EP), GLP/GMP, FDA 21 CFR Part 11 and other regulations.... Read More |