An infrared spectrophotometer is an analytical instrument used to identify materials including organic polymers. Infrared spectrophotometers record the relative amount of energy as a function of the wavelength/frequency of the infrared radiation when it passes through a sample. Therefore, chemical structures of different samples will reflect differences in the IR absorption spectrum allowing for identification of a sample. Unlike a dispersive spectrometer, an FTIR spectrometer or FTIR spectrophotometer is used to simultaneously obtain spectral data of a sample. It does this by using an interferometer to collect the interferogram, also known as the raw data/signal format, which can then be translated into the infrared spectrum of the sample by means of a fourier transform algorithm. As a result, there are many advantages including greater signal-to-noise ratio, high resolution, higher throughput, and a short wavelength limit. FTIR spectrometers can be used in a variety of industries including environmental, pharmaceutical, and petrochemical.
Find, compare, and request a quote for infrared spectrophotometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |
| Company | Bruker Optics | Bruker Optics | Bruker Optics |
| Item | INVENIO FT-IR Spectrometer | ALPHA II FTIR Spectrometer | EM27 Open Path FTIR Spectrometer |
| Citations | | | |
| Catalog Number | Invenio | ALPHA II | BOPT EM27 |
| Price | | | |
| Wavelength Range | Inquire | 350 to 8000 cm-1 with standard KBr beamsplitter
500 to 6000 cm -1 option High Humidity ZnSe optics | σ = 700 – 5000 cm-1 (active mode)
σ = 700 – 3800 cm-1 (active mode with ultrafast scanning)
σ = 700 – 2200 cm-1 (passive mode) |
| Signal-to-Noise Ratio | 60’000:1 1 min sample measurement, 4 cm-1, peak-to-peak | > 55,000:1 | Inquire |
| Resolution | < 0.085 cm-1 | Better than 2 cm-1, optional better than 0.75 cm-1 | Δσ = 1 cm-1 (0.5 cm-1 optional) |
| Optical System | Inquire | KBr windows and beamsplitter, optional High Humidity optics with ZnSe beamsplitter and ZnSe windows | KBr or ZnSe (option) beam splitter f0.9. Throughput: 0.0082 sr cm2 |
| Description | The INVENIO is made to innovate from routine quality control to advanced research and development. Whether you focus on productivity, precision or if you must comply to extensive regulations, the INVENIO supports you in every regard.
Features:
- Newly designed beam path for high signal to noise
The INVENIO is made to innovate from routine quality control to advanced research and development. Whether you focus on productivity, precision or if you must comply to extensive regulations, the INVENIO supports you in every regard.
Features:
- Newly designed beam path for high signal to noise
- Embedded touchscreen PC for the quickest and most efficient FT-IR analysis (optional)
- Second sample compartment for parallel availability of two IR-setups (TransitTM)
- MultiTect™ technology adds 5 detectors, allowing up to 7 internal detectors in total
- Optional precise INTEGRAL™ interferometer with < 0.085 cm-1 resolution and 3x beamsplitter changer for fully-automated multispectral range spectroscopy
- SoC electronics provide spectroscopic precision and low energy consumption
- Unique Bruker FM to measure MIR and FIR in one go
- Expandable from FIR to VIS/UV and to time resolved spectroscopy
... Read More | The FTIR spectrometer ALPHA II combines outstanding quality with a small footprint and sets a benchmark in terms of user convenience. With the integrated panel PC and the touch-based operation, FTIR spectroscopy has never been easier.
Intuitive & Integrated
The ALPHA II features a new way to The FTIR spectrometer ALPHA II combines outstanding quality with a small footprint and sets a benchmark in terms of user convenience. With the integrated panel PC and the touch-based operation, FTIR spectroscopy has never been easier.
Intuitive & Integrated
The ALPHA II features a new way to operate an FTIR spectrometer. With the integrated panel PC and the dedicated OPUS-TOUCH user interface it takes only three touches for measurement, evaluation and report generation. OPUS-TOUCH is very intuitive and guides you conveniently through the measurement and evaluation process.
Enhanced Performance
The ALPHA II represents the enhanced follow-up model of the very successful ALPHA spectrometer. Due to technical innovations such as advanced stabilization of source and detector it provides several improvements like higher sensitivity, higher spectral resolution, extended spectral range and higher robustness against changes in ambient temperature.
The ALPHA II includes a durable diode laser operated with patented technology to achieve a very high wavenumber accuracy. The well-proven RockSolidTM interferometer accomplishes consistent high-quality results with outstanding stability.
Efficiency in Routine Analysis
The ALPHA II offers all the capabilities needed for efficient routine analysis. It is ideally suited for quality control tasks like incoming goods inspection or the testing of intermediate and final products.
The identification of unkown samples as a common requirement in failure analysis, competition analysis, and forensics is extremly simple with the ALPHA II.
The ALPHA II is further very suitable for quantitative analysis providing optimal measurement conditions for all types of samples.
Design Follows Application
The QuickSnapTM sampling modules for the ALPHA II offer full sampling flexibility. They allow the analysis of almost any kind of sample (e.g. solids, liquids or gases) each with perfectly matched instrument configuration.
Multiple sampling accessories for transmission, attenuated total reflection (ATR), external and diffuse reflection are available to fulfill the requirements for many different analytical questions.
... Read More | The Open Path Gas Analyzer EM27 is a broadband infrared detection system for remote sensing of hazardous atmospheric compounds. The system performance allows real-time field screening analysis (analysis less than 1 s). The lightweight system includes an infrared radiation analyzer based on the The Open Path Gas Analyzer EM27 is a broadband infrared detection system for remote sensing of hazardous atmospheric compounds. The system performance allows real-time field screening analysis (analysis less than 1 s). The lightweight system includes an infrared radiation analyzer based on the proven Bruker RockSolid™ interferometer. An internal calibration source provides self-test and self-calibration for radiometric measurements. Due to the novel design of the sensor module, the system is resistant to mechanical shocks, vibrations and temperature extremes. It is hardened for field operations in harsh environments.
In order to cover a large range of field application purposes, EM27 has two different system configurations with different sensitivities: Passive mode uses the natural infrared radiation signatures of chemical agents. Active mode detection uses the transmitted light from an active infrared source.
Features - Easy handling
- Robust and compact design
- Low weight
- Minimal power consumption
- Fast measurement and analysis time
... Read More |
| Get Quote | | | |