
X-ray fluorescence spectrometers use high-energy X-rays (or gamma rays) to excite fluorescent radiation from a sample for quantitative chemical or elemental analysis and have many industrial and research applications. Elements with an excitation energy less than the x-ray beam fluoresce and can be counted by a wavelength-dispersive or energy-dispersive spectrometer. The advantages of X-ray fluorescence spectrometers are that there is no need for sample prep (the material can simply be placed in the beam), and that it is a non-destructive analysis technique. This is ideal for fields like archeology, where destructive analytical methods are not an option. X-ray spectrometers are also gaining importance in response to increasing demand for lead testing in consumer products. Speed and sensitivity are prime considerations in choosing an X-ray fluorescence spectrometer. Ease of use and good analytical software are also important.
Find, compare, and request a quote for XRF analyzers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
Get Quote for All
Select up to 5 products from below to compare or request more information.
Sponsored Products
Malvern Panalytical
- Energy Dispersive X-ray Fluorescence
- Metal-ceramic side window for maximum stability, 50 micrometers thin beryllium window for high sensitivity for light elements, Ag anode X-ray tube for best performance of P, S and Cl analysis
- High-resolution silicon drift detector (SDD)
- 24 mm
Malvern Panalytical
- Wavelength Dispersive X-ray Fluorescence
- 4 kW SST-mAX X-ray Tube (Super Sharp X-ray Tube)
- Hi-Per Scint Detector, Duplex Detector
- up to 300 mm
Malvern Panalytical
- Wavelength Dispersive X-ray Fluorescence
- Super Sharp X-ray Tube (SST), up to 4 kW, 60 kV and 125 mA
- Hi-Per Scint Detector, Duplex Detector
- Inquire
Malvern Panalytical
- ED-XRF
- (Excitation) 4 to 60 kV
Very low drift because of zero-evaporation technology advancement (ZETA) - 4 x High-resolution silicon-drift detectors (SDD)
- 27 mm
Malvern Panalytical
- Wavelength Dispersive X-ray Fluorescence
- 3.0 kW SST R Ag Tube
- Inquire
- Inquire
Malvern Panalytical
- Wavelength AND Energy Dispersive Dispersive X-ray Fluorescence
- No-drift SST R-mAX tube
- Hi-Per Scint Detector, Duplex Detector
- Inquire
Malvern Panalytical
- Wavelength Dispersive X-ray Fluorescence
- Super-sharp SST R-mAX X-ray tubes
- Inquire
- Inquire
Malvern Panalytical
- Wavelength Dispersive X-ray Fluorescence
- Drift-free SST R-mAX X-ray tubes with ZETA technology
- Duplex detector
- Inquire
Malvern Panalytical
- Wavelength AND Energy Dispersive Dispersive X-ray Fluorescence
- SST R 1 kW X-ray tube, Configuration upgrades: 3 or 4 kW X-ray tube
- Inquire
- Inquire
Malvern Panalytical
- Wavelength AND Energy Dispersive Dispersive X-ray Fluorescence
- No-drift SST R-mAX 4 kW X-ray tube, 50 micron window
- Duplex detector
- Inquire
Malvern Panalytical
- SumXcore technology (WDXRF, EDXRF and XRD)
- Rh, Cr, Mo and Au
- HiPer scintillation detector
- 6 mm to 37 mm
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags