X-ray fluorescence spectrometers use high-energy X-rays (or gamma rays) to excite fluorescent radiation from a sample for quantitative chemical or elemental analysis and have many industrial and research applications. Elements with an excitation energy less than the x-ray beam fluoresce and can be counted by a wavelength-dispersive or energy-dispersive spectrometer. The advantages of X-ray fluorescence spectrometers are that there is no need for sample prep (the material can simply be placed in the beam), and that it is a non-destructive analysis technique. This is ideal for fields like archeology, where destructive analytical methods are not an option. X-ray spectrometers are also gaining importance in response to increasing demand for lead testing in consumer products. Speed and sensitivity are prime considerations in choosing an X-ray fluorescence spectrometer. Ease of use and good analytical software are also important.
Find, compare, and request a quote for XRF analyzers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |  |  |  |
| Company | Bruker | Bruker | Bruker | Bruker | Bruker |
| Item | S2 PUMA Series 2 EDXRF Spectrometer | S2 POLAR EDXRF Spectrometer | S8 LION Simultaneous WDXRF Spectrometer | S8 TIGER Series 2 WDXRF Spectrometer | S8 TIGER Series 3 WDXRF Spectrometer |
| Price | | | | | |
| Principle | EDXRF | EDXRF | WDXRF | WDXRF | WDXRF |
| X-Ray Tube | Pd or Ag anode; 50 W, max. 2 mA, max. 50 kV (30 kV available) | 50 W, high-power X-ray tube, max. voltage 50 kV, with polarizing HighSense™ beam path | 60 kV / 170 mA | Rh anode; options: 75 µm Be Window, 50 µm Be Window, 28 µm Be Window; Cr anode max. 3.3 kW | 75 µm Rh End-window; 50 µm Rh End-window with SampleCare™ coating |
| Goniometer Type | Inquire | Inquire | Simultaneous | Sequential | Sequential (optional simultaneous Single-Element or Multi-Element channels) |
| Detector(s) | HighSense™ (Na – Am), HighSense™ XP (C – Am) | HighSense™ ULS Silicon Drift Detector | Proportional flow counters, Sealed proportional counters, Scintillation counter | Proportional flow counter and Scintillation Counter; capacity >3 Mcps, 2 Mcps linear range | Proportional counter, Scintillation counter; optional HighSense GF™ (light elements) or HighSense XE™ for Mn–Am (>12 Mcps linear range) |
| Analysis Diameter | Up to 152 mm | Inquire | Ø 33 – 51.5 mm | 300 µm (minimum spot size) | Spot sizes from 34 mm to 5 mm (5-position mask changer) |
| Get Quote | | | | | |