Raman Microscope / Confocal Raman Microscopes

In Raman microscopy, also called confocal Raman microscopy, an optical microscope and a Raman spectrometer are combined into one instrument in order to provide high resolution images of small samples. This high resolution imaging has applications that include materials science, earth science, cell biology, medicine, cosmetics, and art analysis. A Raman microscope consists of a basic optical microscope, a Raman spectrometer, a laser, a light source, and a detector such as a CCD camera. The optical microscope uses light to magnify and identify samples while the Raman spectrometer scatters light and measures the excitation vibration. When selecting a microscope, it is important to consider the qualities of each of the microscope's components and their optimal configuration for a particular application.

Find, compare, and request a quote for Raman and confocal Raman microscopes across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

Showing 5 of 5 products
  • <<
  • >>
Get Quote for All
Select up to 5 products from below to compare or request more information.
NRS-4500 Confocal Raman Microscope
JASCO
  • Measurement Mode(s):
    Backscattering
  • Detector(s):
    Air-cooled Peltier CCD detector (Max.-60°C)
    1650 x 200 pixel, 16 µm x 16 µm, Visible to NIR
  • Laser Sources:
    Standard: 532 nm, 20 mW
    Optional lasers: 405, 442, 457, 488, 514.5, 532, 633, 785, 1064 nm, etc.
    *Red wavelengths are recommended lasers.
    *In case of 1064 nm, detector needs to be changed to InGaAs.
Citations:
(36)
NRS-5500 Confocal Raman Microscope
JASCO
  • Measurement Mode(s):
    Backscattering
  • Detector(s):
    4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
  • Laser Sources:
    Standard: 532 nm, 50 mW
    Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
    *Red wavelengths are recommended lasers.
    *In case of 1064 nm, detector needs to be changed to InGaAs.
Citations:
(172)
NRS-5600 Confocal Raman Microscope
JASCO
  • Measurement Mode(s):
    Backscattering
  • Detector(s):
    4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
  • Laser Sources:
    Standard: 532 nm, 50 mW
    Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
    *Red wavelengths are recommended lasers.
    *In case of 1064 nm, detector needs to be changed to InGaAs.
NRS-7500 Confocal Raman Microscope
JASCO
  • Measurement Mode(s):
    Backscattering
  • Detector(s):
    4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
  • Laser Sources:
    Standard: 532 nm, 50 mW
    Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
    *Red wavelengths are recommended lasers.
    *In case of 1064 nm, detector needs to be changed to InGaAs.
Citations:
(28)
NRS-7600 Confocal Raman Microscope
JASCO
  • Measurement Mode(s):
    Backscattering
  • Detector(s):
    4-Stage Peltier Cooled CCD Detector (UV-NIR range, 1,024 × 255 pixel)
  • Laser Sources:
    Standard: 532 nm, 50 mW
    Optional lasers: 244, 266, 325, 355, 442, 488, 514.5, 633, 660, 785, 1064 nm, etc.
    *Red wavelengths are recommended lasers.
    *In case of 1064 nm, detector needs to be changed to InGaAs.
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • <<
  • >>
  • Bruker Optics
  • Edinburgh Instruments Ltd
  • JASCO
  • Shimadzu
  • Thermo Fisher Scientific
  • WITec GmbH
  • Zolix Instruments Co., Ltd.
Get the Latest Updates, Technology News and Trends, New Products, Promotions, Buying Tips, and More!

Note: Labcompare disclaims any information on this site.