Atomic Absorption Spectrophotometer

Atomic absorption spectrophotometry analyzes the concentration of elements in a liquid sample based on energy absorbed from certain wavelengths of light (usually 190 to 900 nm). Atomic absorption spectrophotometers typically include a flame burner to atomize the sample (most commonly a hollow cathode lamp), a monochromator, and a photon detector. Depending on the model, some atomic absorption spectrometers are equipped with a turret or fixed lamp socket that can hold multiple lamps (up to eight) to reduce downtime between samples or allow for sequential analysis.

Typical sensitivity for an atomic absorption spectrometer using a flame burner is in the parts per million range. For trace analysis, a graphite furnace can be used in place of a flame burner to increase the sensitivity by several orders of magnitude (in the parts per billion range). Atomic absorption spectrophotometers are used in many industries including environmental testing, metal analysis, semiconductor manufacturing, petroleum and chemical production, and in pharmaceuticals, for example.

Find, compare, and request a quote for atomic absorption spectrophotometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.

CompanyThermo Fisher ScientificThermo Fisher ScientificThermo Fisher Scientific
ItemiCE 3500 AAS Atomic Absorption SpectrometeriCE 3300 AA SpectrometeriCE 3400 AA Spectrometer
Price
Lamps6 (coded, auto-aligning carousel)6 (coded, auto-aligning carousel)6 (coded, auto-aligning carousel)
Beam ConfigurationDouble beam (Stockdale optics)Double beamSelf-referencing Zeeman system
Wavelength Range180-900 nm180–900 nm180–900 nm
Lamp TypeDual atomizer (flame and furnace)Hollow Cathode Lamp (HCL)Hollow Cathode Lamp (HCL)
VaporizationFlame (air/acetylene and nitrous oxide/acetylene) and Graphite FurnaceFlame (50 mm Ti burner)Graphite Furnace, Vapor
SensitivityGuaranteed Quadline deuterium or AC Zeeman background correction; Echelle monochromator; dynamic optical temperature feedback up to 3000 degrees C/sec; Extended Lifetime Cuvettes (ELC)Quadline deuterium background correction with guaranteed performance; spectral bandwidths 0.2, 0.5, and 1.0 nm; Ebert monochromatorGuaranteed Quadline deuterium and AC Zeeman background correction; Echelle monochromator; dynamic optical temperature control up to 3000 degrees C/sec
DescriptionHigh performance, dual atomizer, double beam AA Spectrometer with software-controlled flame/furnace switchingHigh performance, versatile, double beam Atomic Absorption Spectrometer for flame analysis with optional graphite furnace upgradeHigh performance, dedicated graphite furnace Atomic Absorption Spectrometer with Zeeman and deuterium background correction
Get Quote