Spectrofluorometers are designed to detect and quantify fluorophores. These are fluorescent molecules that, when exposed to light, absorb photons at a characteristic wavelength. Subsequently, they then emit photons at a different and slightly longer characteristic wavelength. Spectrofluorometers contain excitation and emission filters for using different fluorophores. Monitoring the activities of molecules labeled with fluorophores is crucial to many kinds of experiments in cell biology, molecular biology and genetics, pharmaceuticals, and forensics, among many others. Emitted light may be detected by photomultiplier tubes or photodiodes within the spectrofluorometer, depending on the model. In addition, users of spectrofluorometers now have a wide range of high-tech fluorophores from which to choose to complement the features of a Spectrofluorometer, also referred to as fluorimeter. Modern fluorometers and fluorimeters are capable of detection as low as 1 part per trillion.
Find, compare, and request a quote for spectrofluorometers across leading suppliers at Labcompare; including access to product citations, related published figures, and first-hand reviews from our scientific community.
|  |  |
| Company | Edinburgh Instruments Ltd | Edinburgh Instruments Ltd |
| Item | LifeSpec-II Dedicated Lifetime Spectrometer | FS5 v2 Spectrofluorometer |
| Citations | | |
| Catalog Number | LifeSpec-II | FS5 v2 |
| Price | | |
| Light Source | EPLs (Picosecond Pulsed Diode Lasers), EPLEDs (Picosecond Pulsed LEDs) | 150 W CW Ozone-free xenon arc lamp (UV-enhanced ozone generating option available) |
| Wavelength Range | 200 to 1700 nm | <230 nm to 1000 nm (Excitation), 200 nm to >870 nm (Emission) |
| Wavelength Accuracy | Inquire | ± 0.5 nm |
| Scanning Speed | Inquire | 100 nm/s |
| Description | The LifeSpec-II is a compact, high performance computer controlled instrument for the acquisition and analysis of time resolved fluorescence, based on the technique of Time Correlated Single Photon Counting (TCSPC).
The instrument has been designed for operation with modern picosecond and The LifeSpec-II is a compact, high performance computer controlled instrument for the acquisition and analysis of time resolved fluorescence, based on the technique of Time Correlated Single Photon Counting (TCSPC).
The instrument has been designed for operation with modern picosecond and femtosecond lasers, such our EPLs (Picosecond Pulsed Diode Lasers), EPLEDs (Picosecond Pulsed LEDs), Titanium Sapphire lasers and supercontinuum sources. These sources enable measurements of fluorescence lifetimes down to tens of picoseconds across the UV-Visibile-NIR spectral regions up to 1700nm.
The LifeSpec-II has the unique feature of having an integrated emission monochromator with zero temporal dispersion. As such, very short fluorescence lifetimes can be recovered without an error introduced by the propagation of light on wavelength dispersive elements, such as the monochromator gratings.
The integrated system features a large sample compartment, with room for many sample holder options, including multi-position sample holders, cryostats, X-Y position sample holders, etc.
The instrument further comprises of computer controlled attenuation of incident light from the laser, optional polarisers, two computer selectable laser input ports and two computer controlled detector exit ports.
A detector shutter is both interlocked to the sample chamber for protection against excessive ambient light, and is also linked to the detector current to protect against overexposure by the laser.
The LifeSpec-II comes in two versions. The first version contains one set of gratings for the operation in the spectral range 200nm to 1000nm. The second version contains two sets of gratings for the operation in the spectral range 200nm to 1700nm.... Read More | Compact high-sensitivity spectrofluorometer; FS5 v2 is adaptable to a wide range of research and analytical applications.
Features:
- High Sensitivity: Photon counting detection, with a signal-to-noise ratio of 12,000:1, provides exceptional sensitivity for the detection of weak fluorescence signals
Compact high-sensitivity spectrofluorometer; FS5 v2 is adaptable to a wide range of research and analytical applications.
Features:
- High Sensitivity: Photon counting detection, with a signal-to-noise ratio of 12,000:1, provides exceptional sensitivity for the detection of weak fluorescence signals
-
2-in-1 Spectrometer: Measure both absorption and fluorescence spectra in a single instrument
-
Adaptable: Tailor to your requirements, from a dedicated spectral fluorometer to an all-in-one characterisation platform with time-resolved fluorescence and quantum yield
-
Plug & Play Sample Modules: Auto-recognised sample modules that can be swapped in seconds, enabling a rapid transition between different sample formats and measurement types
-
Near-Infrared Detection: Extend the measurement range out to 2050 nm by adding a NIR detector, ideal for studying NIR-emitters, such as quantum dots and upconversion nanoparticles
-
Automated Acquisition: Maximise your lab productivity with the FluoAuto software feature to create automated sample measurement sequences
... Read More |